Records from 1982 to 2025. Most recent: operational control imposed, 7 November 2025.
Inspection history · 76
7 November 2025
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8265846
23 October 2025
Administrative Inspection · Appeal · PSC A · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8257477
7 May 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8130232
1 May 2025
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8123998
8 March 2025
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8088822
9 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999506
23 August 2024
PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7984517
31 January 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7858192
22 January 2021
Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 7129263
10 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6973202
26 February 2020
DAPI Audit · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6915823
11 February 2020
Cargo Tank Internal · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6906728
10 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6871499
28 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6728441
25 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6399453
18 April 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6394266
11 April 2018
Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6389849
22 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6184177
23 June 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5917372
22 June 2016
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5915855
25 February 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5822112
12 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5762566
13 May 2014
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4853361
25 August 2011
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4159920
24 August 2011
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4126042
23 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4126047
23 July 2009
Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3543730
15 July 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3268900
15 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3060742
5 July 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2985564
28 April 2006
Deficiency Check · Examination of Repairs · COI Inspection · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2635466
26 September 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501263
21 June 2005
MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2393759
5 May 2004
Examination of Repairs · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2078635
29 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026992
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965059
16 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1929606
27 August 2002
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1670048
31 August 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366576
23 May 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457940
20 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433698
17 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777354
21 June 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393178
17 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808244
30 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804466
25 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461003
3 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106653
3 October 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400426
5 December 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428561
18 October 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392087
8 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 649741
23 August 1994
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868091
22 August 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 182928
4 October 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 649742
1 October 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353482
5 September 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180389
27 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170184
27 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412460
9 November 1992
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468711
8 October 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250089
9 September 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932400
14 November 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210892
8 November 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 913537
24 March 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199110
24 March 1989
MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347488
6 December 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 898164
15 November 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 895096
29 December 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1319407
20 November 1986
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020631
14 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304545
22 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294478
13 December 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976330
6 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279141
12 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279440
22 December 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964979
12 November 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963871
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 October 2025
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties. Instructions which are essential to be provided prior to sailing should be identified, documented and given. The crew was not familiar with the shipboard emergency procedures regarding the fire drill. The crew failed the fire drill 02 times because of their inability to properly don firefighting equipment and follow shipboard firefighting procedures. A safety management audit report satisfactory to the Captain of the Port must be submitted prior to the clearence of this deficiency.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 5 November 2025
Resolution: Safety Management Audit was completed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 23 October 2025
Resolved
A ship when in a port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. The fire team did not properly don firefighting equipment. The crew was not familiar with SCBA operations, which resulted in dispensing 02 SCBA bottles. Additionally, crew was not familiar with shipboard firefighting procedures, such as not securing ventilation. This resulted in a failure of their fire drill 02 times.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 5 November 2025
Resolution: Subsequent drills and training were completed
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2025
No resolution recorded
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met. (1) the ship shall be subdivided by thermal and structural boundaries (2) thermal insulation boundaries shall have due regard to the fire risk of the space and adjacent spaces: and (3) the fire integrity of the divisions shall be maintained at openings and penetrations. The galley, accommodation spaces, and the navigation bridge are not separated by thermal or structural boundaries. The fire control plan fails to indicate any "A" or "B" class divisions throughout the ship. This deficiency constitutes a significant and unmitigated hazard of both fire and safe navigation if the bridge fills with smoke while underway.
Condition: Invalid
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 October 2025
No resolution recorded
Ducts provided for ventilation to accommodation spaces, service spaces or control stations shall not pass through... galleys... unless they comply with the conditions specifies in paragraphs 7.2.2.1.1 to 7.2.2.1.3 or 7.2.2.2.1 and 7.2.2.2.2. A single ventilation system connects the galley, the accommodation spaces, and the navigation bridge without complying with the precautions in the specified paragraphs. Of note, the ducts were neither insulated to "A-60" standard nor fitted with fire dampers. When asked how they would secure the galley ventilation in the event of a fire, the crew could not answer the question. This deficiency constitutes a significant and unmitigated hazard of both fire and safe navigation if the bridge fills with smoke while underway.
Condition: Improper Installation
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2025
No resolution recorded
The activation of any detector or manually operated call point shall initiate a visual and audible fire detection alarm signal at the control panel and indicating units. if the signals have not been acknowledged within 2 min, an audible fire alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. This alarm sounder system need not be an integral part of the detection system. The smoke detectors in the galley and accommodation spaces were modular isolated household smoke detectors that were connected to a fixed system and did not initiate a visual and audible signal at the control panel.
Condition: Improper Installation
Action required: 30 - Ship detained
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 23 October 2025
No resolution recorded
For ships constructed before 1 July 1998, the Administration shall ensure that when life-saving appliances... are replaced or... undergo repairs, alterations or modifications of a major character which involve replacement... they comply with the requirements of this chapter. Each launching appliance shall be so arranged that the fully equipped survival craft or rescue boat it serves can be safety launched against unfavorable conditions of trim of up 10 degrees and list of up to 20 degrees either way when boarded. The rescue boat was replaced in 2012. The davit must be physically swiveled by manpower alone, and the crew struggled to rotate the davit with no persons in the rescue boat while moored to the pier in calm weather conditions.
Condition: Invalid
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025
Resolved
An onboard means of recharging breathing apparatus cylinders used during drills shall be provided or a suitable number of spare cylinders shall be carried on board to replace those used. The vessel only had a total of 04 SCBA bottles on board for 02 fire fighting outfits. Following the drill, 02 SCBA bottles were required to be refilled at a shoreside facility leaving only 02 bottle remaining on board
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Vessel has 06 SCBA bottles on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 October 2025
Resolved
Not less than 12 rocket parachute flares, complying with requiremnts of section 3.1 of the Code, shall be carried and be stowed on or near the navigation bridge. The vessel only has 06 parachute flares.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Vessel recieved the 06 missing parachute flares.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 23 October 2025
Resolved
Every line-throwing appliance shall include not less than four lines, each having a breaking strength of not less than 2 kN. The vessel only had 02 line-throwing appliances.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Vessel received the 02 missing line throwing appliances.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical wires were exposed in the freezer above the door and in the engine room on the main engine controls.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 October 2025
Resolved 5 November 2025
Resolution: Vessel fixed the exposed wiring.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 23 October 2025
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. The vessel was missing discharge placards
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 October 2025
Resolved 5 November 2025
Resolution: Vessel installed a discharge placard
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 October 2025
Resolved
Every oil tanker of 150 gross tonnage and above and every ship of 400 gross tonnage and above other than an oil tanker shall be provided with an Oil Record Book Part I (Machinery space operations). The Oil Record Book, whether as a part of the ship’s official logbook or otherwise, shall be in the form specified in appendix III to this Annex. The soundings of the dirty oil tank were not being logged weekly. Additionally, the sounding logs (i.e. tank capacity, tank level, etc.) were not in accordance with the ORB’s instructions.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 October 2025
Resolution: Class surveyor notated an entry within the ORB that the incorrect information was identified and training was conducted.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 7 May 2025
Resolved
The Oil Record Book, whether as part of the ships official logbook or otherwise, shall be in the form specified in appendix III to this annex. PSCO observed weekly soundings of tanks listed in item 3.1 of from A of the IOPP certificate was not being logged per ORB part I section (C)11.
MARPOL Annex I/17.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2025
Resolution: Chief Engineer performed a weekly sounding and logged it IAW ORB part 1 and received training.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed port and starboard liferafts have not been serviced in the last twelve months.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2025
Resolution: MSU Lake Worth recieved Class documentation and images of liferafts in service in position. Vessel will recieved original liferafts after service.Please refernce Documents for CLass letter.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 8 March 2025
Resolved
A ship when in a port or an offshore terminal of another Party is subject to inspection by officers duly authorization by such a Party concerning operational requirements under this Annex there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the prevention of pollution by oil. During Port State Control Exam, Port State Control Officer discovered manufacturer's operational instructions for the oily water separator were no on board vessel and master and crew were not familiar with how to properly operate the oily water separator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2025
Resolution: Vessel submitted Class report and technician report attesting to the crew being trained on proper operation of the OWS and obtaining proper instructions for operation.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 28 June 2019
Resolved
Oily water separator discharge valve did not fully close during function test. Repair prior to use.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 6 August 2019
Resolution: Vessel submitted photos & video of newly installed OWS valve, working as intended.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2019
Resolved
CO2 portable extinguisher located in engine room, near OWS, hose is wasted. Replace hose prior to departure from port.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2019
Resolved 28 June 2019
Resolution: Vessel received replacement portable fire extinguisher on-board, sent documentation and picture to attending MI.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 June 2017
Resolved
Oily water seperator was inoperable. Vessel to have fully operational OWS prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2017
Resolution: Vessel provided satisfactory evidence of operable OWS.
Deck/Cargo › Ballast › CBT
Issued 22 June 2016
Resolved
Make permanent repair to #3 STBD mud tank (used as ballast tank only) deck plating. Deck plate peeled back with 4" hole.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 24 June 2016
Resolution: Permanent repair to #3 STBD mud tank deck plate complete. Passed air test. Ref. Houma Missle Activity 5917372 for repair.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 June 2016
Resolved
Make permanent repair to STBD bulwark from frame 49 to 52F.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 24 June 2016
Resolution: Permanent repair to the bulwark is complete. Ref. Missle activity 5917372 for repair.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 22 June 2016
Resolved
Make permanent repair to forward #3 STBD mud tank vent bell.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 24 June 2016
Resolution: #3 Mud tank vent bell repair complete. MSU Houma Missle activity 5917372 for repair.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 February 2016
Resolved
Fire Drills and Abandon Ship drills not being conducted on alternate weeks in the proper timelines as required by 46CFR131.535 and 46CFR131.525
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 25 February 2016
Resolution: Company's Safety Manager updated company's policy and drills matrix.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 February 2016
Resolved
Multiple improper splices were found on vessel not in junction boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 25 February 2016
Resolution: Corrected, splices placed in junction boxes and pictures emailed to Marine Inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 25 February 2016
Resolved
Charts not updated with current local to mariners.
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 25 February 2016
Resolution: New Chart for the current area brought on board.
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2011
Resolved
Crop and renew stbd bow bulwark and adjacent main deck plating. Repair bent fwd masthead and masthead light. Crop and renew deckplate fracture where masthead light joins main deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 September 2011
Resolved 30 August 2011
Resolution: MSU Houma MI witnessed all repairs as well as witnessed NDT on all aplicable repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2006
Resolved
Provide guards for moving parts on port/stbd diesel generators.
Condition: Unknown
Due 30 May 2006
Resolved 10 May 2006
Resolution: Guards installed.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 April 2006
Resolved
Flexible fuel lines cannot exceed 30". Install fixed fuel piping systems on P/S MDE's.
Due 30 May 2006
Resolved 10 May 2006
Resolution: Fixed piping installed.
Engineering › Pressure Vessel › Pressure Gauge
Issued 28 April 2006
Resolved
Replace guage on stbd air receiver.
Due 28 May 2006
Resolved 28 April 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 28 April 2006
Resolved
Seal wiring & A/C duct iwo engine room passageway, as noted.
Due 10 June 2006
Resolved 10 May 2006
Documentation › Certificates/Documents › Stability Letter
Issued 28 April 2006
Resolved
Provide stability book to coincide w/ updated stability letter.
Due 10 June 2006
Resolved 10 May 2006
Engineering › Gas Turbine (propulsion-electric) › Shaft
Issued 28 April 2006
Resolved
Prove proper operation of shaft tachometers.
Due 10 May 2006
Resolved 10 May 2006
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 28 April 2006
Resolved
Replace/ provide approved rescue harness.
Due 30 May 2006
Resolved 10 May 2006
Documentation › Certificates/Documents
Issued 16 October 2003
Resolved
Provide proof of FCC Station license. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Documentation › Certificates/Documents
Issued 16 October 2003
Resolved
Provide proof of Bridge-to-Bridge certificate. LEGACY COMPONENT DESC: Bridge to Bridge Certificate
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Lifesaving › Inflatable Liferafts
Issued 16 October 2003
Resolved
Label liferaft stations on superstructure. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Documentation › Safety/Response Plans/Programs
Issued 16 October 2003
Resolved
Provide updated Fire Safety Plan to the Coast Guard for approval. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Operations/Management › Drills/Instruction
Issued 16 October 2003
Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Electrical › Lighting (emergency)
Issued 16 October 2003
Resolved
Provide metal guard for operating station emergency light. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Lifesaving › Lifebuoys
Issued 16 October 2003
Resolved
Renew 02-deck lifebuoy floating light. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2003
Resolved 14 November 2003
Lifesaving › Inflatable Liferafts
Issued 16 October 2003
Resolved
Renew stbd liferaft hydrostatic release. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2003
Resolved 14 November 2003
Construction/Loadline › Structures
Issued 16 October 2003
Resolved
Renew gaskets on stbd operating station weather tight door and 01 deck watertight door. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2003
Resolved 14 November 2003
Electrical › Electric Supply System (service)
Issued 16 October 2003
Resolved
Provide ventilation louver for operating station back-up battery. LEGACY COMPONENT DESC: Battery Installation Ventilation
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003
Resolved
Provide protective guard for stove light. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 14 November 2003
Lifesaving
Issued 21 June 1999
Resolved
01. DEMONSTRATE COMPLIANCE WITH CG DISTRICT 8 RESCUE BOAT POLICY DATED 12NOV99.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 9 September 1991
Resolved
REPAIR STAINLESS STEEL FIRE MAIN - 1 PLACE ON 6" LINE - 4 PLACES ON 10" LINE. QUALIFIED WELDER AND MATERIALS TO BE USED. HYDRO SAME IN PRESENCE_x001C_ OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Navigation
Issued 15 November 1988
Resolved
ADMIN EXTENDED TWO DAYS
Condition: Unknown
Due 15 November 1988
Resolved 15 November 1988
Electrical
Issued 15 November 1988
Resolved
ADMIN EXTENDED TWO DAYS
Condition: Unknown
Due 15 November 1988
Resolved 15 November 1988
Engineering
Issued 15 November 1988
Resolved
ADMIN. EXTENDED TWO DAYS
Condition: Unknown
Due 15 November 1988
Resolved 15 November 1988
Deck/Cargo
Issued 15 November 1988
Resolved
ADMIN EXTENDED TWO DAYS
Condition: Unknown
Due 15 November 1988
Resolved 15 November 1988
Fire Fighting
Issued 22 January 1986
Resolved
EFFECT PERMANENT REPAIRS TO WASTED FIRE MONITOR PIPING.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Electrical
Issued 13 December 1984
Resolved
REPAIR PORT S/S GENERATOR OVERSPEED TRIP WITHIN SEVEN (7) DAYS OF THE ABOVEDATE BUT NOT LATER THAN 20DEC84.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984
Resolved
REPAIR STBD MAIN ENGINE OVERSPEED TRIP WITHIN SEVEN (7) DAYS BUT NOT LATER THAN 20DEC84.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984
Resolved
REPAIR PORT AND STBD MAIN ENGINE REMOTE STOPS TO COMPLETELY SECURE ENGINES WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984