Records from 2010 to 2017. Most recent: inspection, 26 August 2017.
Inspection history · 8
26 August 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6308067
29 November 2015
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5771788
8 September 2015
COC-MODU Annual
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5746807
8 August 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4948157
2 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4237028
1 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4236330
3 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4217873
25 October 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3955848
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 8 September 2015
Resolved
The pressure relief valve in the air system was frozen and not working properly.
Condition: Improper/Lack of Maintenance
Due 22 September 2015
Resolved 12 September 2015
Resolution: Pressure relief valve was replaced. System is working properly now.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 8 September 2015
Resolved
The rescue boat was onshore being serviced. The lifeboat davits do not meet the retrieval speed requirement to allow lifeboat to be used as rescue boat. Standby vessel is required to act as rescue boat while rescue craft is on-shore.
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Rescue craft is back on board and in-service.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 25 October 2010
Resolved
Make Repairs to provide for proper operation of steering system in lifeboat #1.
Condition: Improper/Lack of Maintenance
Due 1 November 2010
Resolved 25 October 2010
Resolution: Cleared while still on board.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 25 October 2010
Resolved
Replace smoke float on starboard bride wing ring buoy.
Action required: 705 - Other - as specified
Resolved 22 November 2010
Resolution: Cleared per [name withheld] email dated 22 Nov 2010.
Lifesaving › Lifebuoys › Size
Issued 25 October 2010
Resolved
Replace port wing buoy in quick release with proper bridge buoy.
Action required: 705 - Other - as specified
Resolved 29 November 2010
Documentation › Markings/Placards › Warning Signs
Issued 25 October 2010
Resolved
Properly label all alarms and strobes throughout the vessel and ensure proper operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 November 2010
Construction/Loadline › Structures › Door
Issued 25 October 2010
Resolved
Make adjustments or repairs to ensure proper, full closure of door to heat exchanger room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 25 October 2010
Resolved
Make repair or replacement to ensure proper operation of watertight door lights in spaces as discussed.
Action required: 705 - Other - as specified
Resolved 22 November 2010
Resolution: Cleared per [name withheld] email dated 22 Nov 2010.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 October 2010
Resolved
Provide proof of current hydro test at 1.5x MAWP for all fuel and oil transfer hoses prior to use of hoses.
Action required: 705 - Other - as specified
Resolved 26 October 2010
Resolution: Cleared per [name withheld] email dated 26 Oct 2010.
Accommodation/Occupational Safety › Heating › Piping
Issued 25 October 2010
Resolved
Redirect discharge flow from waste heat water maker rupture disks in a safe direction to minimize/eliminate hazards to personnel.
Action required: 705 - Other - as specified
Resolved 22 November 2010
Resolution: Cleared per [name withheld] email dated 22 Nov 2010.