MAERSK SENTOSA
MAERSK SENTOSA is a freight ship. The Coast Guard has recorded 68 inspections since 2016, most recently in June 2026, along with 54 deficiencies, 3 operational controls and 1 casualty investigation in 2018.
Records from 2016 to 2026. Most recent: inspection, 10 June 2026.
- Built
- Not recorded
- Last inspected
- 10 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 54 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2018
Identity
1276348
9315202 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WSEP
1096974
Flag
UNITED STATES
369246000
Maury page id
psix-1096974
Inspections, by type
…with no type recorded6
Years with a record
11 calendar years (2016–2026)
The 68 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)1,012.8 ft × 131.2 ft × 66.2 ft
Registered tonnagegross 80,503 / net 50,098
ITC dimensions (L × B × D)1,012.8 ft × 131.2 ft × 66.2 ft
ITC tonnagegross 80,503 / net 50,098
BuilderHYUNDAI HEAVY INDUSTRIES CO LTD · KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 7 August 2026 · expires 30 September 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92991 - Dead Weight, Ton
121278 - Displacement, Ton
80503 - Convention (Subpart B), Gross Ton
50098 - Convention (Subpart B), Net Ton
121278 - Displacement, Ton
80503 - Convention (Subpart B), Gross Ton
50098 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WSEPMMSI 369246000 · active · compulsorily equipped · granted 13 March 2017, expires 13 March 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 68
10 June 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8397263
17 March 2026
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8327515
16 October 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8253736
27 June 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8168796
17 June 2025
MSP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8161263
30 March 2025
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8101314
28 December 2024
Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 8051585
9 September 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7999649
5 June 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7928905
31 May 2024
MSP Select Handover Survey · MSP Annual Oversight · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7924465
12 April 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7894531
13 October 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7808044
13 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811882
28 September 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7799680
29 August 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780584
21 June 2023
Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7720032
29 May 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7699521
23 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7628145
9 August 2022
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528673
9 August 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7529512
17 May 2022
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7461090
2 May 2022
MSP COI Oversight · MTSA/ISPS Verification · COI Inspection · MSP Select Handover Survey
Physical examination · Activities Europe · Activity 7442036
18 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 7398293
5 August 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7278278
26 May 2021
Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7207567
6 May 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7190580
16 March 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7145089
16 March 2021
MSP Periodic Oversight
Type not classified · Sector Virginia · USCG East District (CGD-E) · Activity 7156913
4 March 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7150294
12 February 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7140201
12 February 2021
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7140209
7 February 2021
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7136960
5 February 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7136965
17 September 2020
MTSA/ISPS Verification · MSP Annual Oversight · Annual Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7051638
17 September 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7093956
8 September 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7052953
4 September 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7050206
1 July 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6992410
11 June 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6974503
11 March 2020
MSP Periodic Oversight
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925254
9 March 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6926028
7 January 2020
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6876102
6 August 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6774501
1 August 2019
MTSA/ISPS Verification · Ballast Water Examination · Administrative Inspection · Periodic Inspection · MSP Periodic Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6766155
16 July 2019
Plan Review (Other than "T") · Administrative Inspection
Administrative · Activities Europe · Activity 6770368
20 February 2019
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6628658
17 February 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6627397
7 January 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6606746
20 December 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6600630
15 October 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6561205
15 August 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6512193
9 July 2018
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6469048
29 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6380993
23 March 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6377472
13 March 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6370925
12 February 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353950
24 January 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6344137
12 January 2018
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6337445
12 January 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6338235
27 December 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6329350
7 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6302214
27 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6296532
25 August 2017
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6251476
2 August 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6248375
29 July 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6224053
23 July 2017
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6218464
24 March 2017
Reflagging & Initial Certification
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6110673
5 October 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6008234
Deficiency record · 54
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 29 August 2023
Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel MAERSK SENTOSA a report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating, or the OCMI within whose jurisdiction the voyage is completed. Vessel master/rep made sailing short notification for the position of able bodied seaman from Newark NJ, to Charleston, SC. 46 CFR 15.725
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2023
Resolved
A life jacket complying with the requirements of
paragraph 2.2.1 or 2.2.2 of the Code shall be provided
for every person on board the ship.
MI's observed 23 life jackets at that Port and STBD side
lifeboat muster stations that were not SOLAS or 46 CFR
160.155 approved.
Vessel shall rectify prior to sailing on an
international voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 June 2023
Resolved
Before the ship leaves port and at all times during the
voyage, all life-saving appliances shall be in working
order and ready for immediate use.
During lowering of life boat evolution, MI's observed
dead man brake lever for the port lifeboat failed to
release and engage brake when crew member released
pressure dead man brake lever.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 June 2023
Resolved
The machinery, boilers and other pressure vessels,
associated piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended.
MI's discovered steam piping leak in port generator
compartment and leak in boilers upper sight glass level
valve.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 9 August 2022
Resolved
Except as provided by § 15.725 of this part, no vessel may be navigated unless it has in its service and on-board the crew complement required by the COI. Prior to the vessel sailing on a international voyage proof must be provide, to the local Officer in Charge, Marine Inspection,(OCMI), that the vessel is fully manned in accordance with the Certificate of Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 May 2022
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: thermal insulation of boundaries shall have due regard to the risk of fire of the space and adjacent spaces. MI identified missing insulation in lower level E/R port side where recent ballast water tank repair was made. Make repairs in accordance with applicable regulations to ensure proper fire protection is maintained in the space.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 2 May 2022
Resolved
An International Oil Pollution Certificate shall be issued to any other ships of 400 gross tonnage and above which are engaged in voyages to ports or offshore terminals under the jurisdiction of other Parties to the present Convention. MI noted that the approval date for the SOPEP did not match the current approval letter. Lloyd's Register surveyor corrected the discrepancy and issued an updated IOPP Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 2 May 2022
Resolved
The revised NOX Technical Code 2008 shall be applied in the certification, testing, and measurement procedures for the standards set forth in this regulation. MI identified the serial number on the Main Engine #1 EIAPP Certificate did not match with the Engine's NOX technical file. Lloyd's Register surveyor corrected the discrepancy and issued an updated EIAPP Certificate.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 8 April 2022
Resolved
The 10-81 Gap Evaluation for MSP transfer to U.S.
Registry of MAERSK SENTOSA (and MAERSK SELETAR) Prepared
for Maersk Line Ltd by CG International dated March 2017
(Rev. 1) identified the following would be completed
prior to the vessel’s next scheduled drydock (see page 19
of the Gap Evaluation):
Prior to or during the next drydocking the following
item will be installed to meet the requirements of 46
CFR 62 for Periodically Unattended Machinery Space: The
approved LR Test Procedure for maintaining the EO class
endorsement will be reformatted and submitted to the
Marine Safety Center to meet the requirements contained
in 46 CFR 61.40-1 and 46 CFR 61.40-6.2.
USCG Marine Inspectors called to attend drydock for credit on 02 APR 2022. The above item was not completed. Vessel to provide proof of submission to USCG Marine Safety Center or Lloyd’s Register (LR ACP Supplement and MSC MTN 04-03) as specified in NVIC 01-13 CH-1 to attending marine inspector within 30 days.
Cite: NVIC 1-13 CH-1 and Gap Evaluation for MAERSK SENTOSA dated Mar 2017
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 8 April 2022
Resolved
The 10-81 Gap Evaluation for MSP transfer to U.S.
Registry of MAERSK SENTOSA (and MAERSK SELETAR) Prepared
for Maersk Line Ltd by CG International dated March 2017(Rev. 1) identified the following would be completed prior to the vessel’s next scheduled drydock (see page 19 of the Gap Evaluation):
• The existing engine room bilge pump will be fitted
with controls for automatic start and stop operation
activated by a level float switch in the forward engine
room bilge well. The pump is not fitted with an excess
run alarm as required by 46 CFR 62.35-50 but will be so
fitted.
• Remote control of the engine room watertight sliding
door will be installed in the ECR.
USCG Marine Inspectors called to attend drydock for
credit on 02 APR 2022. The above items were not
completed. Vessel to provide proof of completion for
these items to attending marine inspector within 30
days.
Cite: NVIC 1-13 CH-1 and Gap Evaluation for MAERSK SENTOSA dated Mar 2017
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 3 April 2022
Resolved
The Company should establish procedures to ensure that
the ship is maintained in conformity with the provisions
of the relevant rules and regulations and with any
additional requirements which may be established by the
Company. In accordance with the Gap Evaluation submitted
to USCG by Maersk Lines Ltd for the MSP transfer of
MAERSK SENTOSA to U.S. registry, items were identified
to be installed and/or completed by the next scheduled
drydock for the Periodically Unattended Machinery Space operations. The vessel had 5 years to effect these
procedures/repairs but remain outstanding.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2021
Resolved
The condition of the ship and its equipment will remain fit to proceed to sea without danger to the ship or persons on board. Observed soft patch and leak on the #2 SSDG spinner lube oil filter piping.
74SOLAS(14)I/11(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2021
Resolved
The condition of the ship and its equipment will remain fit to proceed to sea without danger to the ship or persons on board. Observed wasteage on the starboard side B deck in the vicinity of the lifeboat launching area, the port side railing in the vicinity of the lifeboat launching area on B deck, and the second longitudinal in board of the starboard side on the B deck aft mooring station.
74SOLAS(14)I/11(a)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 May 2021
Resolved
The condition of the ship and its equipment will remain fit to proceed to sea without danger to the ship or persons on board. Vessel had extinguished emergency lighting on the starboard side embarkation in the vicinity of the lifeboat and the upper deck adjacent to bay 63.
74SOLAS(14)I/11(a)
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 16 March 2021
Resolved
Maintenance of condition after survey. Found in proper mechanical plug being used on port side A deck fuel oil containment.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 March 2021
Resolved
All-lifesaving appliances shall be in working order and ready for immediate use. Able Seaman immersion suit does not fit.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2021
Resolved
Maintenance of condition after survey. Found two improper fire extinguisher brackets being used in engine room and steering gear room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 March 2021
Resolved
Maintenance of condition after survey. Found port side A deck door dogs taped and loose.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 March 2021
Resolved
Maintenance of condition after survey. Found emergency lighting on the port and starboard life boat embarkation stations extinguished. Crew corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 March 2021
Resolved
All life-saving appliances shall be in working order and ready for immediate use. Port side embarkation ladder attachment D ring is wasted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 March 2021
Resolved
Maintenance of condition after survey. Found two fire detectors in engine room being held in place with tape.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 September 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Additionally maintenance, testing and inspections of life-saving appliances shall be carried out in a a manner having due regard to ensuring reliability of such appliances. The Port and Starboard forward life raft embarkation ladders were found to be installed too close to the movable gate rendering them unable to be put over the side. Additionally, the port and stbd emergency embarkation lighting stanchion was found seized in place and unable to be swung over the side of the ship as well as the stowage bracket for the emergency embarkation light in the forward Bosun locker was found seized in place rendering the crew-member unable to properly deploy the light to the embarkation station. In addition six life-jackets were found un-serviceable in the vicinity of the port and stbd embarkation stations. Vessel shall correct the above deficiency to the satisfaction of the RO prior to departure from port.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 September 2020
Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge. The sliding watertight door located in way of the engine room and shaft alley was found to have a broken shaft coupling rendering it unable to be remotely opened from the bridge. Vessel shall submit a risk assessment and a plan on how they plan to mitigate this hazard along with a repair proposal to the satisfaction of the RO prior to departing the port.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 September 2020
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company, in meeting these requirements, the company should ensure that: inspections are held at appropriate intervals. When asked for the LifeSaving inspection intervals for the apparatus at the forward port and stbd abandon embarkation stations out of the vessels Safety Management System (Lloyds Shipmanager), vessel crew were unable to provide it. They did however provide a periodic maintenance item for the ships embarkation ladders that stated they were to be deployed over the side of the ship or laid out along the deck and inspected. This maintenance item had not been completed and was overdue at the time of the inspection. They could not provide any more documentation to the testing or maintenance procedures or requirements for the forward lifejackets, emergency embarkation station, or the emergency embarkation light.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 September 2020
Resolved
The company should establish procedures for the implementation of corrective action, including measures to prevent recurrence. When inspectors inquired through the whether class or flag had been notified of the failed control mechanism, they were told the port engineer stated he forgot to make notification. Maersk Document ID: 10-01-01 dated 03JAN20 states that if any critical equipment becomes defective and requires unplanned maintenance the master shall report to the relevant authorities in accordance with SMS procedures: Reporting of Statutory defects(Doc ID: 09-04-01.900) and Port State Control and Flag State control (Doc ID: 05-111.900). No notification was made to Flag State or to the RO.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 September 2020
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company, in meeting these requirements, the company should ensure that: records of these activities are maintained.
Multiple Lockout-TagOut tags were identified during the course of the inspection that were either completely void of the information or missing significant portions of information required by Maersk Line, Limited Lockout-Tagout procedures contained in document ID: 07-01-02-01.900, more specifically the section labeled, Tagout Devices, must meet the following specifications: 3. Have a clearly visible, unique identifier, 4. Identify the date and individual who applied the tag. Further, a tag was found attached to motor controller breaker with a nylon cable tie. Maersk Line procedures specifically state that nylon cable ties are not an acceptable Lockout Device. Records reviewed during the inspection showed that the Chief Engineer completed an Audit of the Lockout-Tagout log on August 6, 2020, however according to the Lockout-Tagout log the deficient tags had been in place prior to the audit with no findings.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 17 September 2020
Resolved
As delineated in deficiencies 1-5, Objective evidence attests to the vessel’s crew failing to effectively implement basic SMS procedures related to reporting deficient critical equipment, adhering to on board lifesaving maintenance schedules, and procedures related to safe working practices and procedures as it relates to Lockout-Tagout. The failure of the implementation of the SMS poses a significant risk to the safety of the crew.
An Additional Internal verification of the vessels SMS focusing on the above items is required within 30 days in accordance with CVC-WI-003(2), USCG Oversight of Safety Management Systems on U.S. Flag Vessels.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 September 2020
Resolved
Satisfactory means shall be provided for the protection of the crew in the necessary work of the ship. During the course of the inspection several transverse catwalks between cargo holds on the main deck were found corroded and wasted rendering them unsafe to walk on. This was persistent throughout the vessel forward of the accommodations.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 September 2020
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the organization and shall include at least the following fire protection systems: ventilation systems, including fire and smoke dampers and their controls. Multiple raised trunk C02 protected cargo hold ventilators were found severely wasted, holed, and corroded. In addition, several of these ventilators were found to be unable to properly seal when operated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 September 2020
Resolved
The construction and the means for securing the weather tightness of cargo and other hatchways in positions 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. Multiple weather tight cargo hatch covers were found to be without dogs due to sever corrosion. This discrepancy was evident throughout the cargo deck forward of the accommodation. Further, the STBD access hatch to the fin stabilizer room was found misaligned and unable to maintain a watertight condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020
Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. The 220V Ballast for Sodium Lamps electrical boxes located in the forward bosun hole were found to be subject to saltwater intrusion from above. This was causing the boxes and associated wiring to be exposed to salt water causing corrosion. Specifically Ballast for L10-8. These electrical enclosures have no ingress protection rating. Additionally inspectors discovered 01 conductors in way of aft end of bay 14 had appeared to be ground out and melted the outer core of the conductor exposing the inner wiring to salt water ingress.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 September 2020
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. A smoke detector in the fwd bosun locker was found with broken bracket and hanging from the overhead by the wires.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 September 2020
Resolved
Hoses specified in this chapter as “fire hoses” shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Deck station 24 was missing a spanner wrench.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 September 2020
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. The port side life raft embarkation ladder connection point to the deck was found 50% wasted.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 March 2020
Resolved
SOLAS (2014) II-2/9.1.3 - FIRE INTEGRITY OF THE DIVISION SHALL BE MAINTAINED AT OPENINGS AND PENETRATIONS. FIRE STOP MISSING ON BULKHEAD AND DECK CABLE RUNS IN ELECTRICAL SPACES ON E AND F DECK.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2020
Resolved
74 SOLAS (2014) II-2/14/2.1.1.1 - FIRE PROTECTION SYTEMS SHALL BE KEPT IN GOOD ORDER TO ENSURE REQUIRED PERFORMANCE IF (1) NO.3 HOLD HATCH COVER (CO2 PROTECTED SPACE) FOUND UNLOCKED, MISALIGNED AND MISSING THREE CLOSING DEVICES. (2) STAIR WELL FIRE DOORS ON E AND F DECK DID NOT LATCH. (3) FWD GOOSE NECK VENT COVER HINGE COMPLETELY WASTED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020
Resolved
74 SOLAS (2014) II-1/40.1.3 - ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF THE CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE INSURED. (1) STEP UP TRANSFORMER FOUND IN USE AND UNSECURED ON TOP OF ICE MACHINE. (2) SEVERED GROUND WIRES ON (M6) MOORING DRUM MOTOR, MECH EXH FOR NO.9 HOLD VENT, AND P-WAY FWD(S) EXT MV-17 VENT. (3) STEEL ELECTRICAL CONDUIT WASTED AND JAGGED COMPROMISING THE SAFETY OF THE ENCLOSED CABLES.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 March 2020
Resolved
ICLL 1966 25.2 - SATISFACTORY MEANS SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN THE NECESSARY WORK-OF THE SHIP. (1) SAFETY BAR MISSING. (2) GRATING SEVERELY WASTED ON PORT-SIDE MIDSHIP CATWALK. NO PERS CAN SAFELY TRANSIT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 August 2019
Resolved
Cargo ship survival craft embarkation arrangements shall be so designed that the lifeboats can be boarded and launched directly from the stowed position
*The port lifeboat and starboard showed signs of wastage on the davit. The davit points that hold the pulleys for the cable to control launching from the inside the boats are very thin. 4 Areas total
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2019
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage.
*In the Bosun locker, there was an extension cord hard wired to the ship.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 October 2018
Resolved
Portside liferafts were damaged from heavy weather.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 October 2018
Resolved
Rails aft of house were damaged during the fall of the stores crane.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 October 2018
Resolved
Port lifeboat suffered damaged to hull during heavy weather event.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 October 2018
Resolved
Side stiffener of port side accomodation ladder is damaged. Class issued a Short Term Safety Equipment Certificate for 15 days.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 13 March 2018
Resolved
VDR malfunctioned due to water ingress on the main capsule. VDR is currently recording on a flash drive.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 12 February 2018
Resolved
1. Gear has found to be broken in steering gear box at helm for starboard lifeboat. Therefore, preventing lifeboat manufacturer's original means to steer the vessel, relying solely on the emergency tiller. Prove proper operation of original steering system to the satisfaction of USCG and Class. Due date: prior to sailing foreign.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 December 2017
Resolved
Vessel's starboard pilot embarkation ladder corroded and requires replacement
Lifesaving › Lifeboat › Propulsion Engine
Issued 30 October 2017
Resolved
Vessel's port lifeboat engine has seized during routine testing. Replacement engine is procured with deliver on or about 07 NOV 2016 while in Savannah, GA. Prior to sailing foreign, the vessel must repair/replace the port lifeboat engine.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 29 July 2017
Resolved
VESSEL TO COMPLETE REPAIRS TO VDR PRIOR TO DEPARTING FROM NEXT PORT (GERMANY). PROVIDE TECHNICIAN REPORT & CLASS REPORT TO USCG STATING VDR IS FULLY OPERATIONAL.
Documentation › Certificates/Documents › Engine EPA Approved Technical File
Issued 18 May 2017
Resolved
Vessel must provide EIAPP certificates as proof of emissions compliance once issued bt the EPA. MARPOL VI/13 MEPC. 177(58)
Fire Fighting › Firemans Outfit › Axe
Issued 18 May 2017
Resolved
Vessel must provide at least 08 fire axes easily accessible and visible throughout the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 5 October 2016
Resolved
1410-Propulsion main engine-The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. Lower main engine block seal between No. 6 and No. 7 main bearing is leaking. 74 SOLAS (04) II-2/4.2.3.1
Engineering › Fuel Oil Service System › Piping
Issued 5 October 2016
Resolved
1470-Insulation wetted through (oil)-The arrangement for the storage of flammable oils shall be such as to ensure the safety of the persons on board. Excessive fuel leak on No.1 and No. 2 fuel oil feed pumps in purifier room. Excessive fuel soaked lagging and fuel oil in containment rail unit of main engine. Excessive fuel soaked lagging in main engine fuel oil supply unit. 74 SOLAS(04) II-2/4.2.4
Engineering › Steam System (main) › Valve
Issued 5 October 2016
Resolved
1499-Propulsion-The machinery, other pressure vessels, associated piping systems shall be installed to reduce danger to persons on board. Steam leak at No.1 fuel oil heater inlet valve in purifier room. 74 SOLAS (04) II-1/26.1
Casualty record · 1
12 January 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6338235
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.