MAURY USCG vessel records
← All vessels

HMM VANCOUVER

HMM VANCOUVER is a 2010 freight ship. The Coast Guard has recorded 15 inspections since 2017, most recently in July 2026, along with 3 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 28 July 2026.

Built
2010
Last inspected
28 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9463085
1097543
Flag
REPUBLIC OF KOREA
Maury page id
psix-1097543

Documentation record

Tonnage as PSIX records it72634 - Convention (Subpart B), Gross Ton
24576 - Convention (Subpart B), Net Ton
71987 - Dead Weight, Metric Ton
99577 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BARBARA JEAN MULHOLLAND Towing Vessel · MISLE 1223203 · 11 April 2017 · activity 6216552

Inspection history · 15

28 July 2026 Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8448869
10 June 2026 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8397800
20 February 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8313535
26 December 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8287404
26 August 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8218618
11 July 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8178624
24 May 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8142720
24 May 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8162366
20 May 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8139980
25 March 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095235
19 September 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6815373
17 February 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6356772
13 April 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6124104
11 April 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6216552
31 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6080251

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 March 2025 Resolved
74 SOLAS 2009 II-2/4.1.1-THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIAL OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED SIGNIFICANT OIL LEAKING FROM THE RUNNING NUMBER 1 GENERATOR WITH OIL SOAKED RAGS STUFFED BETWEEN THE EQUIPMENT TO CONTROL LEAKAGE. PSCO OBSERVED SEVER OIL LEAK ON CYILNDER 05 AND SMALL LEAK ON SYLINDER 04.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2025
Resolved 25 March 2025
Resolution: Generator #1 and Cylinders 4 and 5 were repaired to the satisfaction of RO and Coast Guard.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Approval for exhaust gas cleaning system
Issued 25 March 2025 Resolved
MARPOL 2017 ANNEX VI/4.1- THE ADMINISTRATION OF A PARTY MAY ALLOW ANY FITTING, MATERIAL, APPLIANCE OR APPARATUS TO BE FITTED IN A SHIP...USED AS AN ALTERNATIVE TO THAT REQUIRED BY THIS ANNEX. PSCO OBSERVED WATER PRESSURE SENSOR FOR EGCS WAS MALFUNCTIONING AND CREW HAD REPORTED CONTINUED USE OF THE SYSTEM DESPITE INOPERABLE SENSOR.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 March 2025
Resolved 4 April 2025
Resolution: The malfunctioning water pressure transmitter sensor for the EGS system was replaced with a new one and found to be in good working order.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
74 SOLAS 2009 II-1/45.10.2- NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT, R.G... IN PAINT LOCKERS...UNLESS THE ADMINSTRATION IS STATISFIED THAT SUCH EQUIPMENT IS... OF A TYPE WHICH WILL NOT IGNITE THE MISXTURE CONCERNED. EXPLOSION PROOF LIGHTS IN PAINT LOCKER AND BATTERY ROOM WERE NOT PROPERLY FITTED AND ABLE TO IGNITE FLAMMABLE GAS.
Action required: 10 - Deficiency Rectified
Due 25 March 2025
Resolved 25 March 2025
Resolution: Explosion proof light cover was tightened and properly installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.