Records from 2010 to 2026. Most recent: operational control imposed, 10 June 2026.
Inspection history · 27
10 June 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8397588
10 June 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8401104
4 June 2026
PSC B · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8390779
5 July 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8175495
18 June 2025
PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8160243
20 March 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8096533
11 January 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7848209
20 June 2023
PSC B
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7718721
25 May 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7696274
31 March 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7660345
19 April 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7433866
22 March 2022
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7413729
4 January 2022
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7372713
5 May 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7189763
5 November 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7090089
12 May 2020
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6951807
8 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6885672
14 December 2019
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6874558
24 September 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6815695
23 September 2019
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6818911
6 December 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6318756
27 October 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6030662
8 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5871541
5 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869585
17 July 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5180591
7 June 2014
Administrative Inspection · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4884891
13 December 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3905847
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2025
Resolved
The construction of doors and door frames in "A" class divisions with the means of securing them when closed, shall provide resistance to fire as well as to passage of smoke and flame, equivalent to that of the bulkheads in which the doors are situated, this being determined in accordance with the fire test procedure code. Such doors and doors frames shall be constructed of steel or other equivalent material. Watertight doors need not be insulated. PSCO observed class "A" boundary fire door frames within the engine room having worn and town gaskets preventing the appropriate level of protection.
Cite: 04 SOLAS CH. II-2 REG. 9.4.1.1.2
Action code: 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2025
Resolution: Received class report and photos. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2025
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores or similar spaces, unless the administration is satisfied that such equipment is:
.3 appropriate to the space concerned.
PSCO observed explosion proof light covers in the purifier room and main engine space had incorrect covers that did not fit the light fixtures and failed to seal properly.
CITE: 04 SOLAS CH.II-I REG. 45.10.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2025
Resolution: Received class report and photos. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 January 2022
Resolved
Oil fuel pipes from a capacity of 500L and above shall be fited with a cock or valve directly on the tank capable of being closed from a safe posistion outside the space cocerned. found a spacer placed in the quick closing valve, preventing the closure of the valve from outside the space.
74 SOLAS(08) II-2/4.2.2.3.4 Action 17c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2022
Resolved 4 January 2022
Resolution: Crew revomed the spacer.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 January 2022
Resolved
(Compressed gas) Cylinders must always be secured, and when not in use, they must be stowed in a rack in an upright posistion. found oxygen/acetylene tanks lashed with rope and not in rack.
46CFR147.60(b) Action 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 10 January 2022
Resolution: Crew satisfactorily fixed Cylinder installation.