MAURY USCG vessel records
← All vessels

MAERSK DETROIT

MAERSK DETROIT is a freight ship. The Coast Guard has recorded 71 inspections since 2016, most recently in April 2026, along with 16 deficiencies, 8 operational controls and 7 casualty investigations between 2016 and 2021.

Records from 2016 to 2026. Most recent: inspection, 28 April 2026.

Built
Not recorded
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 April 2026
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9333034
1098081
Flag
UNITED STATES
Maury page id
psix-1098081

Documentation record

Registered dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
Registered tonnagegross 74,642 / net 44,243
ITC dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
ITC tonnagegross 74,642 / net 44,243
BuilderHANJIN HEAVY INDUSTRIES & CONSTRUCTION CO. LTD · KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74642 - Convention (Subpart B), Gross Ton
44243 - Convention (Subpart B), Net Ton
94480 - Dead Weight, Ton
120331 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GEMINI Towing Vessel · MISLE 1172166 · 17 October 2021 · activity 7336391

Inspection history · 71

28 April 2026 Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8357064
3 November 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8262225
12 April 2025 MTSA/ISPS Verification · Annual Inspection · MSP Select Annual Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8104310
4 April 2025 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8105205
30 March 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8102120
6 June 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7929127
15 May 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7913993
18 March 2024 MTSA Verification · MSP Annual Oversight · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7878950
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7808098
15 August 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7768710
24 July 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7751103
18 July 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7750805
14 June 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7714710
24 May 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7695551
8 March 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7647821
24 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626489
21 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7624904
11 January 2023 Administrative Inspection · MSP COI Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7619920
7 January 2023 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7617842
4 January 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7641384
8 December 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7606478
17 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7536423
24 June 2022 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7485837
14 June 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7476936
6 June 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7469857
10 May 2022 Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7447336
21 March 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7415563
14 December 2021 MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7365518
24 October 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7371489
17 October 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7336391
5 August 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7277800
19 April 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7178274
13 April 2021 MTSA/ISPS Verification · MSP Annual Oversight · Ballast Water Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7174549
11 March 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7154017
12 February 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7140310
8 February 2021 Type not recorded
No type recorded · Activities Europe · Activity 7140880
22 December 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7115057
22 December 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7115058
16 October 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7078252
13 May 2020 MTSA/ISPS Verification · MSP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6949727
25 November 2019 MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6862066
22 November 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6860852
25 March 2019 MSP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6648734
22 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613939
18 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6612329
5 November 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6574961
1 November 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572590
20 October 2018 Type not recorded
No type recorded · Activities Europe · Activity 6566274
10 July 2018 Type not recorded
No type recorded · Activities Europe · Activity 6476292
4 June 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6434126
1 June 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6431428
22 March 2018 MTSA/ISPS Verification · DAPI Audit · MSP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6361456
10 March 2018 Type not recorded
No type recorded · Activities Europe · Activity 6370935
25 August 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6255916
17 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126002
13 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123902
7 March 2017 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6100608
9 November 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038128
9 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038508
28 September 2016 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6011637
17 June 2016 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5909479
24 May 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5895957
19 April 2016 Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 5857262
7 April 2016 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5849414
28 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842391
24 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5839583
18 March 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5835916
18 February 2016 Type not recorded
No type recorded · Activities Europe · Activity 5817236
18 February 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5817239
11 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5795994
8 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5794162

Deficiency record · 16

10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 30 March 2025 Resolved
Each self-propelled vessel, except as provided in paragraph (d) of this section, must have an electric or mechanical engine order telegraph system from the navigating bridge to the engineroom. M/V MAERSK DETROIT was outbound MSU Savannah's OCMI zone when we recieved a report that the vessels main engine bridge telegraph (EOT) was not operating.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 14 April 2025
Resolved 4 April 2025
Resolution: Recieved report from vessel's classification society attesting to corrective action and operability.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 January 2023 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire hose on Port Bridge wing had multiple leaks throughout hose. Hose on Port D-2 area had leak near coupling fitting. 74 SOLAS (09) II-2/14.2.1.2
Action required: 15 - Rectify deficiencies by next port
Resolved 18 January 2023
Resolution: Received Statement no. 2165052 from LR as accepting condition.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 January 2023 Resolved
The function of the fixed fire detection shall be periodically tested to the satisfaction of the administration by means or equipment producing hot air at the appropriate temperature,….. The vessels approved PSTP stated that heat detectors were to be tested with a heat gun in accordance with ships “blue book”. This publication listed a specific Heat Detector with part number FD 2000 002 01 01. Vessel did not have the proper heat gun as per the approved PSTP. 74 SOLAS (09) II-2/7.3.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2023
Resolution: Received Statement no. 2165052 from LR as accepting condition.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 14 January 2023 Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. 1 of 2 fire extinguishers on Rescue boat had bad charge. Corrected on spot by new extinguisher being purchased. 74 SOLAS (20) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 18 January 2023
Resolution: Received Statement no. 2165052 from LR as accepting condition.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 August 2022 Resolved
Every ship shall be provided with radio installations capable of complying with the functional requirements prescribed by regulation 4 throughout its intended voyage and, unless exempted under regulation3, complying with the requirements of regulation 7 and, as appropriate for the sea area or areas through which it will pass during its intended voyage, the requirements of either regulation 8, 9, 10 or 11. Vessel reported their MF/HF radio was inoperable. SOLAS 74 (2020 Con. Ed.) IV/6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 1 September 2022
Resolution: Received Lloyd's Register survey report that a new MF/HF radio had been installed
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 May 2021 Resolved
Maintenance, testing and inspections of lifesaving appliances shall be carried out based on the guidlines developed by the organization. Vessels port life boat remote brake release cable failed to operate properly and cable was found damaged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2021
Resolution: Cleared by Lloyds Register class report Cert No: 2113936
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 May 2020 Resolved
Cargo ship's shall carry at least one rescue boat complying with the requirements of section 5.1 of the code. Vessel's rescue boat bridal is needing renewal. Replace rescue boat bridal prior to embarking on an international voyage. 74 SOLAS (14) III/31.2
Action required: 702 - Prior to embarking on international voyage
Due 15 May 2020
Resolved 15 May 2020
Resolution: To be cleared by Class. See Llyod's statement # 2071900.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 April 2019 Resolved
Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. STBD Lower life raft shell is damaged
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 18 April 2019
Resolution: Vessel had life raft serviced in Houston.
Lifesaving › Lifeboat › Hatches
Issued 26 April 2017 Resolved
Each totally enclosed lifeboat shall be so arranged that access to the lifeboat is provided by hatches which can be closed to make the lifeboat watertight. The hinge on the aft door of the lifeboat was bent preventing the door from being watertight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 27 April 2017
Resolution: Vessel submitted class report attesting to the repair of the hinge on the aft hatch.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 April 2017 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Several cable penetrations in junciton boxes and panel boards were missing packing throughout the STBD tunnel and engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 May 2017
Resolution: Received class report attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 April 2017 Resolved
Machinery and associated piping systems and fittings shall be so installed and protected to reduce to a minimum any danger to persons on board with due regard being paid to hot surfaces. Several hot pipes were missing lagging in the STBD tunnel. Additionally, the lagging on the #3 generator was soaked with oil creating a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 May 2017
Resolution: Received class report attesting to proper repairs.
Fire Fighting › Firemans Outfit › Air Hose
Issued 26 April 2017 Resolved
All fire fighters outfits shall consist of a set of personal equipment and a breathing apparatus. Two of the breathing apparatus's on board had dry rotted hoses leading to the level indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 May 2017
Resolution: Received class report attesting to proper repairs.
Electrical › Electric Generation Source (emergency) › Generator
Issued 9 November 2016 Resolved
Prior to departing Port of NY/NJ provide a report from your ACS that necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies with the applicable regulations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2016
Resolution: See class report
Documentation › Markings/Placards › Warning Signs
Issued 17 June 2016 Resolved
Mark all safety & other applicable equipment IAW 46 CFR 97.37 includign GA alarm, CO2 alarm & fire extinguisher locations.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 28 September 2016
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 18 February 2016 Resolved
Vessel reportrd faulty voltage regulator on the #2 generator.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 6 March 2016
Resolution: Replaced faulty regulator.
Engineering › Generator (propulsion-electric) › Switch
Issued 18 February 2016 Resolved
Verify proper operation of the automation of the emergency generator.
Due 10 March 2016
Resolved 6 March 2016
Resolution: System was tested with satisfactory results.

Casualty record · 7

18 February 2016Routine · role: Involved in a Marine Casualty · activity 5817236
24 May 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5895957
9 November 2016Routine · role: Involved in a Marine Casualty · activity 6038508
10 March 2018Routine · role: Involved in a Marine Casualty · activity 6370935
20 October 2018Routine · role: Involved in a Marine Casualty · activity 6566274
8 February 2021Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7140880
17 October 2021Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 7336391
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record