Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it26435 - Convention (Subpart B), Gross Ton 13016 - Convention (Subpart B), Net Ton 34283 - Dead Weight, Metric Ton 46379 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 July 2022Resolved
Where the emergency source of electrical power is a generator, it shall be provided with a source of emergency electrical power unless an emergency generator is provided capable both of supplying the services and of being automatically started and supplying the required load as quickly as is safe and practicable subject to a maximum of 45s. Emergency generator is capable of taking on load under test.
74 SOLAS 09 CONS. II-1 43.3.1.3
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: The Vessel is to received a class survey report from DVN and Liberia flag dispensation letter attesting to the rectification of the deficiency. Dispensation letter attached to deficiency.
Access doors and access hatch covers normally closed at sea, intended to ensure the watertight integrity of internal openings, shall be provided with means of indication locally and on the bridge showing whether these doors or hatch covers are open or closed. A notice is to be affixed to each such door or hatch cover to the effect that it is not to be left open. Nos. 86 port and 124 port watertight doors were found with tape disabling the indicators and no. 52 starboard watertight door was found tied open with the indicator disabled by a hose section.
74 SOLAS 09 CONS. II-1 13-1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: The Vessel obtained attestation by the recognized organization to the rectification of the diciciency and completed a limited external audit of safety management system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 July 2022Resolved
The company should establish procedure to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Crew did not follow the procedures detailed in the safety management system. Vessel TGM 2.10.7 A3 item l, fire doors and watertight doors was not completed. Vessel is to complete external audit.
74 SOLAS 20 CONS IX 5
ISM PART A/10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: Vessel undertook a limited external audit or their safety management system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2022Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Water mist system nozzle above the fuel purifiers was leaking.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 July 2022
Resolution: Vessel replaced nozzles, verified by attending RO.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 July 2022Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tankhaving a capacity of 500L and above, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. Valve for high side lube oil tank is leaking air.
Action required: 10 - Deficiency Rectified
Due 19 July 2022
Resolved 19 July 2022
Resolution: The valve for high side lube oil tank air leak was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 19 July 2022Resolved
General arrangement plans shall be permanently exhibited, showing clearly for each deck the fire-extinguishing appliances, etc. Plans shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Fire-extinguishing appliance locations do not match the plan near the BWTS.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 July 2022
Resolution: Vessel moved appliances back to approved locations, verified by attending RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are untended. PSCO observed a temporary repair on a leaking sea water inlet pipe to the ship's Main Diesel Engine.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 15 August 2020
Resolution: Received satisfactory class report from DNV-GL attesting the permanent repair and operation of the jacket water feed line.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 August 2020Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. The entrance door to the steering gear room, and door to a storeroom within the steering gear room both had broken self-closing hinges. Vessel replaced hinges with spare parts onboard; repairs were verified by PSCO.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2020Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported knocking in main engine scavenge unit number 4 and stopped main engine while departing Port Hueneme. Vessel reported loose bolts were found after equipment overhaul the previous day, and that bolts were able to be removed and damage to stuffing box able to be repaired. - SOLAS 74a I/11 - 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2020
Resolved 28 March 2020
Resolution: Deficiency cleared after review and acceptance of DNVGL survey report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 August 2019Resolved
CITE: SOLAS 74(2014) III/34 ACTION: 17ac
LSA - 4.4.6.3
All life-saving appliances and arrangements shall comply with the applicable requirements of the code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. Free fall lifeboat engine was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 23 August 2019
Resolution: Recieved Satisfactory Class report attesting to the repairs conducted on the lifeboat.
Means shall be provided to ensure that the machinery can be brought into operation from the dead ship condition without external aid. Vessel was unable to op[erate in astern propulsion while mooring.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2016
Resolution: recieved class report attesting to the repair.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.