Records from 2010 to 2024. Most recent: inspection, 25 February 2024.
Inspection history · 22
25 February 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7869757
21 February 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7868051
19 October 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7811358
21 March 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7654353
18 February 2023
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7637590
13 July 2021
COC-CHEM Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7250619
1 July 2020
Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6992312
19 June 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6980838
5 September 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6889072
2 September 2019
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6798891
30 August 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6798881
6 July 2019
COC-CHEM & TVE Annual · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6734987
3 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6701866
15 May 2019
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6684822
15 May 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6684981
18 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6612167
29 June 2018
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · COC-CHEM Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6459298
17 May 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148174
23 December 2016
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6058312
28 October 2015
COC-CHEM & TVE Renew · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5748382
7 September 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5237850
4 November 2010
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3883478
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 13 July 2021
Resolved
tHE ANGULAR POSITION OF THE RUDDER SHALL, IF THE MAIN STEERING GEAR IS POWER-OPERATED, BE INDICATED ON THE NAVIGATION BRIDGE. THE RUDDER ANGLE INDICATION SHALL BE INDEPENDENT OF THE STEERING GEAR CONTROL SYSTEM
*PORT STATE CONROL OFFICER WITNESSED ANALOG RUDDER ANGLE INDICATORS ON THE NAV BRIDGE AND IN THE STEERING GEAR ROOM, 04 IN TOTAL, WERE NOT WORKING AT THE TIME OF THE STEERING TEST.*
74 SOLAS (04) II-1 / 29.11.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2021
Resolved 13 July 2021
Resolution: CORRECTED ON THE SPOT
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 28 October 2015
Resolved
1840-Instrumentation- Suitable means shall be provided for the zero and span calibration for both fixed and portable gas concentration measurement instruments, referred to in paragraphs 2.4.2.1. to 2.4.2.4. During calibration of oxygen content meter of IGG system, PSCO observed crew using span gas that expired on 15AUG2014. - SOLAS 74(am) II-2/4.5.5.1.2 FSS CODE 15.2.4.2.5
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 28 October 2015
Resolution: Deficiency was rectified on the spot by inspecting a satisfactory bottle of span gas with valid expiration dates while on board.