Records from 2014 to 2025. Most recent: inspection, 20 October 2025.
Inspection history · 109
20 October 2025
Administrative Inspection · Annual Inspection · MSP Select Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8258090
18 April 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113881
18 April 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113884
15 January 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8063836
10 January 2025
Annual Inspection · Deficiency Check · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8060995
11 October 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8017959
11 October 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8024156
24 September 2024
Administrative Inspection
Administrative · Activities Europe · Activity 8008326
27 August 2024
Administrative Inspection
Administrative · Activities Europe · Activity 8005547
6 July 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7950621
7 March 2024
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7875471
15 December 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7839370
8 December 2023
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7834633
7 December 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7837355
1 December 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7832383
1 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7832514
28 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830572
13 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7807047
14 September 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7791510
11 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7789760
7 August 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7762072
28 June 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7726493
19 June 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7718261
17 March 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7653350
2 February 2023
MSP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7630886
26 January 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7627485
23 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7625413
21 January 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7624870
8 December 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7606448
18 November 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7599019
16 June 2022
Administrative Inspection · MSP Select Additional Oversight – Risk Assessment
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7479468
9 June 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7473123
7 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7470670
18 March 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7414330
18 March 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7414406
18 January 2022
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7381974
18 January 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7383640
15 January 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7386281
12 January 2022
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7379583
11 January 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7378463
15 November 2021
MSP COI Oversight · MSP Select Additional Oversight – Risk Assessment
Administrative · Activities Europe · Activity 7350908
28 June 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7238182
8 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7121813
7 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7121265
6 January 2021
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7120661
1 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7118564
1 January 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7118850
26 December 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7116879
6 October 2020
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7068922
5 October 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7071420
17 April 2020
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940558
13 April 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6938602
18 February 2020
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6911062
19 November 2019
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6857373
19 November 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6874730
18 September 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6814797
18 September 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6815249
16 September 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6813225
5 August 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6773181
30 July 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6768230
9 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6743646
8 July 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6742471
3 July 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6744587
18 April 2019
MSP Annual Oversight · Deficiency Check · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6663775
5 April 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6656803
3 April 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6654856
4 February 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6619768
2 February 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6618911
30 January 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6617547
30 January 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6617835
4 January 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6605477
2 January 2019
Type not recorded
No type recorded · Activities Europe · Activity 6605039
15 December 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6598790
7 December 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6593456
8 August 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6504305
25 July 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6491010
28 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6458080
28 April 2018
Type not recorded
No type recorded · Activities Europe · Activity 6404443
28 April 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6407796
30 March 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6381980
27 February 2018
MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6362698
26 December 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6328963
22 December 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6328009
26 October 2017
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6295379
8 September 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6265006
18 August 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6244418
18 August 2017
Type not recorded
No type recorded · Activities Europe · Activity 6244462
24 July 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6219383
13 June 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6174243
11 May 2017
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6143120
7 May 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6141412
4 May 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6139084
15 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 6041185
13 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6039992
2 November 2016
ISM Oversight · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6035525
13 September 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5999369
9 September 2016
Type not recorded
No type recorded · Activities Europe · Activity 5999377
26 August 2016
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5984233
17 August 2016
MTSA Verification · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5975771
8 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5966897
4 August 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5962175
15 June 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5908058
30 May 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5894221
27 May 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5888962
26 May 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5887298
20 May 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5882352
17 March 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5835392
7 March 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5829981
4 March 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5827259
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2025
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For the purpose, the following functional requirement shall be met:
.fire protection systems and fire-fighting systems and appliances shall be maintained ready for use;
01 CO2 fire fighting bottle was found to be empty approximate 45 days ago in CO2 Room rendering the systems not ready for its intended purpose.
Action required: 702 - Prior to embarking on international voyage
Resolved 25 October 2025
Resolution: Vessel submitted tech report attesting to the repair and reinstallation of bottle.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 January 2025
Resolved
All ships of 300GT and upwards shall be fitted with a 9 GHz radar. Vessel reported that the 9 GHz (X-band) radar is inoperable.
SOLAS 20 V/19.2.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
Resolution: Accepted and cleared by class.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2025
Resolved
Each Captain of the Port may order a vessel to operate in the manner directed when the Captain of the Port has determined that such order is justified in the interest of safety by reason of weather, visibility, sea conditions, temporary port congestions, other temporary hazards circumstances, or the condition of the vessel. While transiting through the Sector VA Regulated Navigation area.
33 CFR 160.111(c)
Action required: 705 - Other - as specified
Resolved 17 January 2025
Resolution: X-Band Radar repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 January 2025
Resolved
Port lifeboat forward and aft davit arms found damaged and/or holed due to contact with davit structure. Starboard lifeboat davit arms showing similar signs of damage.
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
74 SOLAS (14) III/20.1
702 AC
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 20 January 2025
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 11 January 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Multiple safety harnesses in port lifeboat found broken and/or deteriorated. Starboard lifeboat safety harnesses found broken and/or deteriorated. Starboard lifeboat window found with multiple fractures.
74SOLAS (2014)III/20.1
50A
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as conditon of class.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2025
Resolved
Firefighting systems shall be kept in good working order and readily available.
Multiple fire stations throughout cargo deck and main deck found leaking by while in the closed condition.
74 SOLAS (14) II-2/14.2.1.2
50A
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 January 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured.
Multiple electrical enclosures in forward Bosn Locker found broken and unable to close also rendering inoperable remote reach rods for breaker closures. Forward paint locker CO2 control enclosure found broken and unable to close.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 January 2025
Resolved
The means for securing doors shall consist of gaskets and clamping devices and be arranged that they can be operated from both sides of the bulkhead.
Store room watertight hatch found unable to close due to incorrect dogging configuration.
ICCL 1969 Reg 12.1
50A
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea.
Lashing stand port side center cargo hatch 26 found with severe structural damage.
SOLAS (2014) I/11(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 January 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea.
Freezer in galley store room inside latch inoperable.
74SOLAS (2014) I/11(a)
50A
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 January 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Port lifeboat engine stalled multiple times while attempting to clutch in gear box. Corrected on spot and verfified proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2025
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2024
Resolved
Main and AUX machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control.
VSL suffered a loss of propulsion while departing Bayport Terminal, dock #4. VSL shall enact permanent repairs to the satisfaction of the RO.
74 SOLAS II-1/31.1 60ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 October 2024
Resolution: Wartsila service ENG identified there was an issue with the "Dual Serial Interface Module Card" on the diesel governor system. Card was replaced with spare; engine tested multiple times ahead and astern. Vessel found to be in good working order.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 2 February 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board.
Vessels Suez crane had extensive wastage on the luffing
motor cable drum. Repair/replace and prove safe
operation and weight handling capacity to the
satisfaction of the vessels classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 February 2023
Resolved
Every lifebuoy shall, if intended to operate the quick
release arrangement provided for the self-activated
smoke signals and self-igniting lights, have a mass of
not less than 4 kg.
Lifebuoy's on port and stbd side of bridge wings were
incorrectly placed and not suitable for quick release
from the bridge.
Action required: 10 - Deficiency Rectified
Resolved 2 February 2023
Resolution: Vessels crew was able to locate and install correct bridge buoys prior to inspector departure.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 June 2022
Resolved
The launching mechanism shall be so arranged that it may be actuated by one person from a position within the survival craft. During lowering of the Port side lifeboat, inspectors noted that the remote release cable was too long to be pulled form the inside the lifeboat.
Condition: Improper Installation
Action required: 702 - Prior to embarking on international voyage
Resolved 22 June 2022
Resolution: Vessel master provided Lloyd's statement attesting to the proper operation of the lifeboat remote cable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2022
Resolved
The means of control of any fixed gas fire-extingushing
system shall be simple to operate and at each location
there shall be clear instructions relating to the
operation of the systen(FSS 5/2.1.3.1). During
inspection to the CO2 space,inspectors noted that the
instructions for operation of the installed CO2 system
were confusing and not clear for the machinery & cargo
spaces.
If the box containing controls is to be locked, a key to
the box shall be provided(FSS 5/2.2.2.2). It was
observed that the key to open the control box for the
cargo hold was missing.
Maintenance, testing and inspection shall be carried out
having due regard to ensuring the reliability of firefighting
systems(SOLAS III/14.2.2.1). The armored
cabling for CO2 discharge solenoids was found to be
severely wasted and improperly installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2022
Resolution: Recieved Lloyd's FAR
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 16 June 2022
Resolved
General arrangement plans shall be permanently exhibited
for the guidance of the shops officers showing the
location of the various fire-extinguishing particulars
of the ship. Fire control and safety plan is out of date
in identifying the equipment located in the port side
fire control locker and other other spaces on the ship.
Further, it was noted that safety equipment identified
on the class approved plan was out of date. Fire Control
and safety plan was last verified and stamped by class
at vessel new construction approximately 15 years ago.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2022
Resolution: Recieved Lloyd's FAR.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
In addition to the requirements contained elsewhere in
the present regulations, ships shall be maintained in
compliance with the electrical requirements of a
classification society or with applicable standards of
the Administration. Multiple cable ways and cable
hangers throughout the vessel(on deck) were identified
to be wasted, holed, and/or no longer attached as
designed. In addition to this, armored cables for remote
winch controls leading from the forecastle deck were
found to be severely corroded and the cable hangers
wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2022
Resolution: Recieved Lloyd's FAR
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 21 March 2022
Resolved
All ships of 3,000 gross tonnage and upwards shall have: a 3 GHz radar, or where considered appropriate by the administration, a second 9 GHz radar.
Vessel's secondary marine radar is inoperable.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: RO provided tech and class report.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 January 2022
Resolved
During inspection of the rescue boat it was found that the starting battery had a bad terminal connection. Upon further inspection of the rescue boat inspectors discovered a bad clutch linkage resulting in the rescue boat unable to operate with astern propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2022
Resolution: Lloyd's issued Short Term Cargo Ship Safety Certificate. CG-835V has been amended and uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 January 2022
Resolved
Most recent fire extinguisher servicing report showed all fire extinguishers were good with the exception of nine extinguishers. Spot Checked seven of those extinguishers and they still had stickers that read “do not use CO2 cartridge due for replacement” or other very similar verbiage. This led to an expanded inspection and found another 17 extinguishers with the same stickers that were not listed on the service report.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2022
Resolved 18 January 2022
Resolution: Vessel serviced 49 extingushers. RO provided statement of Fact as well as technicians report.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 11 January 2022
Resolved
Any other machinery space shall be adequately ventilated appropriate for the purpose of that machinery. The vessels exhaust air fan in the steering gear room is non-operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2022
Resolution: RO listed new electric motor as "actionable item" with a due date of 17FEB2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2022
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunction of an air compressor and receiver for starting or controlling purposes. Vessels number 3 start air compressor was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2022
Resolution: RO imposed COC with due date of 17February2022.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 January 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During inspection of the rescue boat inspectors discovered a bad clutch linkage resulting in the rescue boat unable to operate with astern propulsion.
The following restrictions apply during transit from Houston, TX to Norfolk, VA. These are in addition to items identified in Vessel's risk assessment:
1) No planned maintenance shall be conducted on the main deck or personnel working aloft over the water at any deck height.
2)There shall be 2 person accountability if personnel are on the main deck.
3)A system to account for personnel that must be on the main deck to include coming and going
Action required: 15 - Rectify deficiencies by next port
Due 24 January 2022
Resolved 24 January 2022
Resolution: Received FAR from Lloyd's due to Sector VA inspector availability.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 November 2021
Resolved
An inspection for certification is a prerequisite of the reissuance of a certificate of inspection. Vessel was not ready for inspection including several required inspection items such as bridge safety and navigation and lifesaving. Provide attestation of completed class survey upon completion.
Action required: 705 - Other - as specified
Due 21 November 2021
Resolved 24 December 2021
Resolution: Vsl provided documentation and Class Report attesting to completion of Class Survey, Issuance of Statutory Certs and completion of USCG Worklist items.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 November 2021
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Due to work being done on the vessel, MIs were unable to conduct drills to evaluate crew competency during emergency situations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2021
Resolved 16 January 2022
Resolution: Sector Houston observed satisfactory drills on board.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 January 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Port/Stbd life jacket bins located at life boat embarkation points are not permanently mounted, instead, they are tied with rope to the stanchions. Permanently mount the port and stbd life jacket bins to the satisfaction of Class. SOLAS 2014 (Cons) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2021
Resolved 8 February 2021
Resolution: Port/Stbd life jacket bins at the life boat embarkation points on B-deck have been permanently secured to surveyor's satisfaction.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 January 2021
Resolved
Fire fighting systems shall be kept in good working order. The fire main hydrant valves on main deck are excessively corroded - some may need replacing. Clean/replace to the satisfaction of Class. SOLAS 2014 (Cons) II-2/14
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2021
Resolved 8 February 2021
Resolution: The fire main hydrant valves on main deck at PorVStbd sides have been chipped/painted and 5 handles replaced. All valves found operational to surveyor's satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2021
Resolved
The arrangements for the utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. The main engine high pressure servo oil casing is cracked and leaking oil. The crack has been siliconed, but appears to be failing. Repair to the satisfaction of Class. SOLAS 2009 (Cons)
II-2.4.2.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: Temporary repair has been done and the permanent repair of the high main engine high pressure servo oil casing to be carried out. Condition of Class due until 17'h of Dec 2021 has been imposed now.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2021
Resolved
Piping systems shall be so installed as to reduce to a minimum any danger to persons on board , due regard being paid to hazards. Crew has wrapped the evap's raw water discharge elbow with a soft patch. Repair to the satisfaction of Class. SOLAS 2004 (Cons) II-1.26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The FW generator evap. brine discharge SW pipe has been temporary repaired by welding and wrapped using soft fiberglass patch. The new pipes have been ordered and will be replaced at next visit in Salalah/Oman. Condition of Class imposed until 05May2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 January 2021
Resolved
Ventilator openings shall be provided with weathertight closing appliances. The galley mushroom ventilator located on the stbd side near the life boat is wasted and not weathertight. Repair to the satisfaction of Class. ICLL as modified '88/'03 Annex I/19
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The corroded part of the galley mushroom ventilator cover has been repaired and found operational to the surveyor's satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The iridium phone satellite cable goose neck on the stbd side on top of the wheel house has wasted in half and has been questionably fiberglassed. Repair to the satisfaction of Class. SOLAS 2014 (Cons) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The iridium ph6ne satellite antenna cable goose neck protection pipe on the Stbd side on top of the wheelhouse has been renewed to surveyor's satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The RAID box stanchion weld, located on top of the wheel house, port side, has separated from the deck. Repair to the satisfaction of Class. SOLAS 2014 (Cons) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The RAID stanchions support pipe has been partly renewed and re-welded to the top of the wheelhouse deck on Port side and found surveyor's satisfaction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The stanchions by way of the transit from the main deck up to the focsle deck are excessively wasted. Repair to the satisfaction of Class. SOLAS 2014 (Cons) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The stanchions (flat and round bars) by the way of the transit from the main deck up to the Forecastle deck have been partly renewed and chipped/painted to the surveyor's satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 January 2021
Resolved
Machinery shall be so installed as to reduce to a minimum any danger to persons on board , due regard being paid to hazards. The Suez Davits rotational gear guard has come loose exposing the gear. Repair to the satisfaction of Class. SOLAS 2004 (Cons)
II-1.26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2021
Resolved 8 February 2021
Resolution: The Suez davit rotation gear guard has been fixed to the davit's structure and covers an exposed gear in full now and found to the surveyor's satisfaction.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 February 2020
Resolved
Several penetrations throughout the cable trunk not properly installed with approved fire stop system.
74 Solas 14 11-2/14.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2020
Resolved 13 April 2020
Resolution: See LR Report 2063171
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 February 2020
Resolved
Supply fan servicing galley missing and wiring inproperly secured IVO starboard lifeboat.
74 Solas 14 1/11 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2020
Resolved 13 April 2020
Resolution: See Report Number: 2063171
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2020
Resolved
The #3 SSDG is inop due to 02 cracked heads. Repair to satisfaction of RO.
74SOLAS(14) I/II(C)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2020
Resolved 13 April 2020
Resolution: See LR Report 2067461
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 February 2020
Resolved
The main engine has excessive oil accumulated around cylinders. Crew cleaned to the satisfaction of CG.
74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 February 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2019
Resolved
On main deck #1 Engine room supply vent has hanging wires, ground wire disconnected and a control box just hanging, properly hang so not to cause injury when handled or touched in the normal manner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 November 2019
Resolved
Aft louvers for the emergency generator will not close on its own. Louvers need to be pushed close by hand. Systems shall be kept in good order so as to ensure their required
performance if a fire occurs for the protection of openings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 19 November 2019
Resolved
Fire door latch leading out of hospital is frozen in place and will not latch. Systems shall be kept in good order so as to ensure their required performance if a fire occurs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 November 2019
Resolved
Wiring shall be installed and supported in such a manner as to avoid chaffing or other damage. The wiring leading to the CO2 control box and CO2 alarm relay box are exposed and not protected by the armor cabling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 November 2019
Resolved
Fire fight appliances shall be kept in good working order and ready for immediate use. The fire dampener on aft mooring deck for CO2 space is wasted and not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 November 2019
Resolved
Fire fight appliances shall be kept in good working order and ready for immediate use. The steering gear exhaust fan fire dampener was not able to be closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received copy of Class Report 2053583 from Lloyds Register
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Remove the perforated sheet metal in the starboard engine room ventilation trunk between fire damper and fan motor to the satisfaction of Class.
SOLAS (14) I/11
Action required: 15 - Rectify deficiencies by next port
Resolved 21 April 2019
Resolution: Cleared by LR class report 2031932
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Make permanent repairs to the fire main in place of temporary patch above fire station outside of the fuel oil purifier room to the satisfaction of Class.
SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Verified corrected by LR on report 2032918
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Make permanent repairs to the auxiliary boiler water feed line in place of temporary patch to the satisfaction of Class.
SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Verified corrected by LR on report 2032918
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Make permanent repairs to the fuel oil drain line flange under the fuel oil purifier room in place of temporary patch.
SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Verified corrected by LR on report 2032918
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Multiple doublers and one soft patch were found on the S1, S3 and S4 salt water cooling lines. Make permanent repairs to the satisfaction of Class.
SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 15 August 2019
Resolution: Cleared by LR 15AUG2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, and other items covered by the survery. Lube oil pump discharge line on #2 SSDG is actively leaking. Repair to the satisfaction of Class.
SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019
Resolution: Verified corrected by LR on report 2032918
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2019
Resolved
Vessel is to have one tug of 3,000 horsepower and one tug of 2,000 horsepower, or one tug of 5,000 horsepower standby the vessel until the vessel's unsafe conditions have been rectified to the satisfaction of the Coast Guard Marine Inspector.
33 CFR 160.111
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 February 2019
Resolution: Vessel was escorted by tugs to outside of the regulated shipping channels to conduct sea trials as authorized by Sector Hampton Roads.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 8 September 2017
Resolved
The hydraulic means of starting EDG is inoperable. Repair and op-test hydraulic starter to USCG satisfaction. Prior to departing next port, install secondary battery bank to supplement primary start batteries. Supplemental batteries shall be of equivalent capacity to the primary bank. An op-test of the secondary battery bank is required to be reported to the USCG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 6 October 2017
Resolution: Received Lloyd's Register class report that hydraulic accumulator tested sat in Cadiz.
Electrical › Electric Generation Source (service) › Generator
Issued 13 September 2016
Resolved
Prove proper operation of #2 generator to satisfaction of attending class surveyor.
Action required: 705 - Other - as specified
Due 24 September 2016
Resolved 25 September 2016
Resolution: Recieved class report from LR verifying proper operation of the #2 generator.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 17 August 2016
Resolved
Activation of any detector or manually operated call point shall indicate a visual and audible fire signal. If the signals have not been received within 2 minutes, an audible alarm shall be automatically sounded throughout vessel. While testing fire detection system, MI found no alarm sounded after 2 min delay. Repair and prove function to attending MI or class surveyor.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2016
Resolution: Company had unit representative come out and re load system. Subsequent tests were sat.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 17 August 2016
Resolved
Cargo ships shall carry at least one rescue boat complying with part 5.1 of the Code. While testing the rescue boat, the vessel crew could not get the throttle to engage. Repair and prove function to attending MI or class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2016
Resolution: Vessel crew re worked the throttle assembly. Subsequent testing was sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 August 2016
Resolved
Based on the following deficiencies and the overall condition of the MAERSK ATLANTA, an internal ISM audit of the vessel's safety management system is required on next voyage. In addition, an external ISM audit is required by 05NOV16. SOLAS 14 I/19 and SOLAS 14 IX/6.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 2 November 2016
Resolution: Requirments of Internal and external audit were met. External audit conducted on 02 November 2016.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 17 August 2016
Resolved
Totally enclosed lifeboats shall be provided with hatches which can be closed to make the lifeboat watertight. Upon inspection, MI found one wedge for dogging the hatch closed on the port life boat missing, and one wedge on the STBD lifeboat broken. Replace wedge to make hatch watertight no later than 31 AUG 16. SOLAS 14 III/31.1.1 LSA CODE 4.6.2.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 26 August 2016
Resolution: Wedges on both lifeboats have been replaced and tested satisfactory.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 17 August 2016
Resolved
Lifeboats shall have handrails providing a secure handhold to aid embarkation and disembarkation. During inspection, MI found grab rail on STBD lifeboat broken off/missing. Replace handrail as lifeboat was designed no later than 31 AUG 16. SOLAS 14 III/31.1 LSA CODE 4.6.2.9
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 26 August 2016
Resolution: Handrail was refitted and tested satisfactory.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 17 August 2016
Resolved
To prevent the ignition of combustible materials or flammable liquids, means shall be provided to control leaks and limit the accumulation of flammable vapours. During the inspection, MI found excessive oil in the bilge under Main Engine with visible leaks coming from the accesses to the scavenger air box. Clean oil from bilge to reduce fire risk and make repairs to ME by 7SEP16 SOLAS 04II-II/4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 26 August 2016
Resolution: Excess oil was cleaned from the noted locations, additional oil was found and cleaned on the spot.
Fire Fighting › Fire Main › Valves
Issued 17 August 2016
Resolved
Fire systems shall be maintained and ready for use. During the inspection, MI found the most forward starboard fire main outlet was leaking a steady stream of water while under pressure. Repair valve to prevent leaking no later than 7 SEP 2016. SOLAS 04 II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 18 August 2016
Resolution: Crew replaced valve. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. MI found wiring in horizontal runs supported with dry-rotted and broken zip ties. These wires need to be properly supported or removed if no longer necessary. MI also found a wire in the BT room laying on a tank with metal shielding corroded off. Replace wire. SOLAS 04 II-1/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 18 August 2016
Resolution: Crew replaced dry rotted zip ties with metal banding. Crew repaired damaged wire. All sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 August 2016
Resolved
Machinery and associated piping and fittings shall be of design and construction adequate for the service for which they are intended. During the inspection, the MI found a water leak on the Hi-temperature side of the #2 Diesel Generator coming from a joint/flange with an improper gasket. Replace gasket and stop leak no later than 07 SEP 2016. SOLAS 04 II-1/26
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 26 August 2016
Resolution: Mechanical seal was replaced, and not leaking was observed.
Lifesaving › Lifeboat › Markings
Issued 17 August 2016
Resolved
Life saving appliances shall be fitted with retro-reflective material IAW Resolution A.658(16). During the inspection, MI found the STBD lifeboat was missing required tape in some areas, and other tape significantly degraded and needing replacement. Replace tape where necessary no later than 07 SEP 2016 SOLAS 14 III/31.1.1 LSA CODE 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 18 August 2016
Resolution: Crew replaced retro reflective tape. All sat.
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 17 August 2016
Resolved
Ships shall be maintained as originally designed and constructed. During the inspection, the MI found the fan missing from the powered ventilation in the Bosun's store on the bow. Replace fan as system was originally designed. SOLAS 04 II-1/1
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 26 August 2016
Resolution: Fan previously removed to replace the faulty galley fan has been placed back in proper service.
Electrical › Electric Generation Source (service) › Generator
Issued 15 June 2016
Resolved
Vessel reported tripping of #2 generator due to high voltage, condition of class is issued. Submit class report attesting proper repair and operation of the affected system.
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 17 July 2016
Resolution: Received class report lifting condition of class for this issue, it is verified that the #2SSDG is operating properly after parts replacement and functional test.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 17 March 2016
Resolved
Voyage data recorder not functioning as intended, in that while the system is recording to the main unit, it is not recording to the exterior capsule. The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained (46CFR90.05-10/SOLAS 2009 Cons Ed, Chap. V Reg 16.1).
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 28 March 2016
Resolution: Received a satisfactory operational test report from service technician.