MAERSK DENVER

MAERSK DENVER is a freight ship. The Coast Guard has recorded 75 inspections since 2014, most recently in August 2026, along with 42 deficiencies, 13 operational controls and 10 casualty investigations between 2013 and 2024.

Records from 2013 to 2026. Most recent: inspection, 5 August 2026.

Built
Not recorded
Last inspected
5 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9332999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1101120
Flag
UNITED STATES
338418000
Maury page id
psix-1101120

Inspections, by type

…with no type recorded28
Years with a record 13 calendar years (2014–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
Registered tonnagegross 74,642 / net 44,243
ITC dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
ITC tonnagegross 74,642 / net 44,243
BuilderHANJIN HEAVY INDUSTRIES & CONSTRUCTION · KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 7 August 2026 · expires 30 September 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74642 - Convention (Subpart B), Gross Ton
44243 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WMDQMMSI 338418000 · active · compulsorily equipped · granted 4 January 2023, expires 20 March 2033
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HIGH PERFORMANCE Tank Ship · MISLE 801572 · 11 April 2016 · activity 5851821

Inspection history · 75

5 August 2026 MSP Select Annual Oversight · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8455692
5 August 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8455964
29 April 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8358120
31 July 2025 MSP Select Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8199121
21 July 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8191245
13 August 2024 Type not recorded
No type recorded · Activities Europe · Activity 7982959
11 July 2024 Deficiency Check · MTSA/ISPS Verification · MSP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7956304
28 December 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7843220
28 December 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7845022
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7807010
20 July 2023 MSP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7741048
24 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626481
8 December 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7606484
31 May 2022 Drydock Exam · Administrative Inspection
Physical examination · Activities Europe · Activity 7510794
12 May 2022 MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7448695
3 May 2022 Administrative Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7443151
7 April 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7427992
18 September 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7346143
7 September 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7306398
3 September 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7303518
2 July 2021 Administrative Inspection · ISM Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7246598
25 June 2021 Deficiency Check · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7235486
22 April 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7180848
22 January 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7128870
26 October 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7084204
17 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7036770
15 August 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7033601
13 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7031920
3 August 2020 Ballast Water Examination · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7023528
20 June 2019 Administrative Inspection · Deficiency Check · Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6751707
16 March 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6645481
1 March 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6635035
8 February 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6632390
20 December 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6600625
14 July 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6497961
13 July 2018 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6469054
26 June 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6456704
26 June 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6457219
26 June 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6467602
23 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6342121
18 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339859
28 July 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6223206
25 July 2017 Type not recorded
No type recorded · Activities Europe · Activity 6222072
14 June 2017 MTSA/ISPS Verification · MSP Select Handover Survey · Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6167362
4 April 2017 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Activities Europe · Activity 6117289
13 March 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6103530
24 February 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6094050
22 February 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6093105
8 February 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6084740
9 December 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072677
17 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6043128
15 September 2016 Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6002601
6 September 2016 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5995537
10 July 2016 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5936979
11 April 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5851821
8 April 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5849926
4 April 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847326
30 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5843975
29 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5807918
22 January 2016 In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5801988
19 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5799552
14 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5797457
11 January 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5794865
27 December 2015 Type not recorded
No type recorded · Activities Europe · Activity 5813209
20 November 2015 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5767577
9 November 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5760064
2 November 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5755965
2 November 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5756515
28 October 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5752588
28 October 2015 MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5754214
17 August 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5214571
20 October 2014 Deficiency Check
Physical examination · Activities Europe · Activity 5008306
13 August 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4953620
13 June 2014 Administrative Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4887513
8 May 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4853341

Deficiency record · 42

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 21 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Received report that two heeling tanks (#4SWBT Port and Stbd) have been contaminated by fuel oil. The mitigation plan submitted by MLL DPA to Sector NY on 23 July 2025 has been reviewed. Vessel shall gain acceptance of said plan by Lloyd's as a condition of class. 74 SOLAS (20) I/11 (a) 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2025
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 21 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Identify the cause and affect permanent repairs to the satisfaction of the OCMI and the RO, prior to next US port after sailing foreign. 74 SOLAS (20) I/11 (a) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 October 2025
Resolution: See attached class report.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 July 2024 Resolved
Before a ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Crew was unable to start rescue boat. 74SOLAS(2020) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2024
Resolution: Lloyd's attended vessel and witnessed proper operation of rescue boat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 12 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea. Inset on side shell with structural damage observed starboard side of engine room, vessel unable to provide evidence showing damage was surveyed and documented by class. 74 SOLAS (04) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2024
Resolution: LLyods attended vessel and issued condition of class due 13OCT2024.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 July 2024 Resolved
Each boiler must be provided with a safety trip control system that automatically closes the master and all burner fuel oil valves upon inadequate boiler air flow to support combustion. Low combustion air safety inoperable on auxiliary generator. 46 CFR 62.35-20 (i)(1) (ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2024
Resolution: See attached report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. Number 4 steering pump breaker remote operator broken requiring opening of cabinet for de-energization. 74 SOLAS(04) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2024
Resolution: See attached report.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 12 July 2024 Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe. Pollution for containment on port side main deck for boiler tank clarified oil holed. 74 SOLAS(04) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2024
Resolution: See attached report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 12 July 2024 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship ans protection of the the environment. Vessel was found to have expired medication in the hospital space cabinet and fridge. Vessels crew has no clear instructions on how to properly maintain inventory logs and when to dispose and replace medication. Company shall establish procedures for maintaining medical inventory and implement these in the vessels SMS. 74SOLAS(2020) IX/3.1 ISM Code Part A/7
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2024
Resolution: See attached report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel reported an issue with their primary electrical power distribution and is currently running off the emergency source of electrical power.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2023
Resolved 28 December 2023
Resolution: Received class survey report stating a condition of class issued and a contingency plan approved until final repair w/ finding number to be rectified 31DEC2023. The documentation is attached it to this activity.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 May 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company, in meeting these requirements, the company should ensure that: records of these activities are maintained. Multiple Lockout-TagOut tags were identified during the course of the inspection that were either completely void of the information or missing significant portions of information required by Maersk Line, Limited (MLL) Lockout-Tagout procedure. Records reviewed during the inspection showed that the [name withheld] had never completed an Audit of the Lockout-Tagout log as per MLL requirements. During the inspection, the MLL procedure presented to the inspectors, Document ID 07-03-04-900 dated 22 September 2017 was found to be out of date as per the procedure in DNV Ship Manager. Vessel is to conduct an audit of Lockout-Tagout procedures and current tags in place. In addition, training shall be held with applicable crewmembers of the proper Lockout- Tagout procedures to be followed. 74 SOLAS (20) IX/3.1 ISM Code 10.2.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2022
Resolution: Successfully completed audit. Sec Virginia recieved, reviewed and cleared def.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2021 Resolved
In a ship in which oil fuel is used, the arrangements for storage, distribution and utilization shall ensure safety of ship and persons onboard. Identified the following leaks: Main engine at fuel pumps, oil leaks at crank case doors on all cylinders, lube oil purifier for #3 seal, #2 generator lube oil leak at outlet gasket, #1 generator at piping aft of filter housing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 7 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 June 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performace if a fire occurs: Fire detection and fire alarm systems. Flame detector in purifier room rendered inoperable by ship's staff while testing. Vessel engineer used heat gun instead of required light as per approved testing procedures.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 7 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2021 Resolved
Fire doors in main vertical zones and stairway enclosures shall be self-closing. Fire door from stairway to F Deck and door leaking to ECR failed to self closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 25 June 2021
Resolution: Class report submitted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 25 June 2021 Resolved
Alarms shall be maintained until accepted and the visual indications of individual alarms shall remain until the fault has been corrected, when the system shall automatically reset to the normal operating condition. 2 active alarms onboard that crew is unable to identify and resolve; "WHR Boiler Operation Abnormal" and "Overload Sludge Burning Pump".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 25 June 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 25 June 2021 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules/regulations. Based on the overall material condition of the vessel as substantiated by the objective evidence cited above, and 117 overdue maintenance items related to machinery. An additional external verification is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2021
Resolved 7 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 June 2021 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Starboard lifeboat culd not start. Rectified by permanent repair of new fuel intake hose. Rectified on the spot.
Action required: 10 - Deficiency Rectified
Resolved 25 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 22 January 2021 Resolved
When in use, the lower end of the accomodation ladder, as well as the pilot ladder, shall rest firmly against the ship's side. Vessel did not implemented procedures and equipment (magnets and rigging) designed for securing combination ladder to the ship's side prior to taking pilots for its inbound transit to Charleston.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 January 2021
Resolution: Company took immediate corrective actions in our presence which enabled both ladders to rest firmly against the hull and made available the holds between the last rung and the trap door.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 July 2019 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. In crew laundry room there is a washer and dryer incorrectly installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2019
Resolved 2 August 2019
Resolution: Received report from LR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2019 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. The lines on the lifebuoys that connect the self igniting lights are deteriorated on a majority of the lifebuoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2019
Resolved 2 August 2019
Resolution: Received report from LR.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 18 July 2019 Resolved
Maintenance shall be carried out to ensure reliability of lifesaving appliances. Embarkation ladders on majority of launching stations are deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2019
Resolved 2 August 2019
Resolution: Received report from LR.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 28 July 2017 Resolved
The #5 Injector Control Unit (ICU) has been found faulty on the main propulsion engine. Upon completion of the repairs to the #5 ICU, and after operational tests have been completed, forward the technician’s report to this office for review prior to the due date.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 29 July 2017
Resolution: Vessels master provide attestation that repairs were completed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 February 2017 Resolved
It was reported that the vessel's S-Band radar failed while in port due to a malfunctioning power unit. MSU Savannah issued an LOD to depart the Port of Savannah. The vessel will make a coastal voyage to Norfolk where a new power unit will be deilivered and replaced.
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 22 February 2017
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 July 2016 Resolved
3 cm Radar is out of commission. Prove proper operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 19 July 2016
Resolution: Received 3rd party tech report stating the radar was repaired and tested.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 22 January 2016 Resolved
Redundant vital auxiliaries must automatically transfer to the backup units upon failure of operating units. Vessel's main engine secondary jacket water pump (stbd) is currently inoperable (motor bearings). Deficiency must be addressed to the satisfaction of CG marine inspector or vessel's classification society.
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 28 January 2016
Resolution: Received class report attesting to proper repairs and operation.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 11 January 2016 Resolved
One of the Gyro Compass Repeater failed.
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 12 January 2016
Resolution: Received class report attesting to repairs.
Documentation › Logs/Records › Oil Record Book
Issued 2 November 2015 Resolved
Page 26 of the Oil Record Book has been signed with pages not completed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 November 2015
Resolved 2 November 2015
Resolution: Ships Master instructed in proper use, deficeincy corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2015 Resolved
Galley fire door will not close properly, fire doors shall hatch close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2015
Resolution: Door adjusted and tested to the satisfaction of the attending Marine Inspector.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 2 November 2015 Resolved
SOLAS training manual missing from crew lounge. Provide training manual in "D"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 8 November 2015
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 November 2015 Resolved
Provide proof of vessel Salvage and Marine Fire-fighting contract. 33 CFR 155.4045
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 3 November 2015
Resolution: Company representative supplied a copy of the required contract on-board the vessel.
Lifesaving › Rescue Boat Equipment › Boat-hook/Safety Boat-hook
Issued 2 November 2015 Resolved
Rescue boat to have the following items that need to be corrected. Sufficient fuel, engine does not remain running, release/brake mechanism missing, control box broken, out dated fire extinguisher(serviced due 2012), broken davit gear guard. SOLAS 73/78 (09) CONS. chp III, reg 20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2015
Resolution: Class report submitted and repairs conducted to the satifactions of attending Marine Inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 October 2015 Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date, the expiration date (anniversary date) for the Certificate of Inspection is 23 July 2017. The 3 month window was 23 October 2015. Prior to departing the Port of NY/NJ, your vessel must go through a USCG Examination
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 3 November 2015
Resolution: Completed annual inspection.
Engineering › Fuel Oil Service System › Piping
Issued 28 October 2015 Resolved
Replace oil saturated lagging on MDE and purifier fuel oil lines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 13 November 2015
Resolution: Cleared by Class (LR).
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 October 2015 Resolved
Fire doors in #1 diesel gen room and #2/#3 diesel gen room do not close properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2015
Resolved 3 November 2015
Resolution: CG-835 onboard indicates deficiency was cleared by SEC NY on this date but not cleared in MISLE.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 28 October 2015 Resolved
Structural fire protection insulation missing from bulkhead above door exiting #2 and #3 diesel gen room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2015
Resolved 8 November 2015
Engineering › Bilge Water Management System › Not Operational
Issued 28 October 2015 Resolved
Replace or repair broken float in stbd tunnel fwd of eng rm door entry.
Condition: Improper/Lack of Maintenance
Due 8 November 2015
Resolved 8 November 2015
Engineering › Steam System (auxiliary) › Piping
Issued 28 October 2015 Resolved
Repair flange steam leak on aux boiler and HFO heater in purifier room.
Condition: Improper/Lack of Maintenance
Due 8 November 2015
Resolved 8 November 2015
Engineering › Feedwater/Condensate Water System › Pump
Issued 28 October 2015 Resolved
Replace mechanical seal on #1 boiler feed water pump.
Condition: Invalid
Due 8 November 2015
Resolved 8 November 2015
Electrical › Electrical Distribution System (service) › Cable
Issued 28 October 2015 Resolved
Armored cable are required to be continous in order to maintain bonding. Throughout engineering spaces, armored cable are not continous to maintain bonding.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 23 November 2015
Resolution: Lloyd's Register surveyor attended vessel and cleared wiring to #1 and #2 feed water pumps def issued 02 Nov.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 28 October 2015 Resolved
Repair emergency generator and prove proper operation of its starting requirements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2015
Resolution: Vessel replace battery sets and reinstalled all new batteries. Batteries are excepting a charge, tested emergency generator. Test satisfactory.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 28 October 2015 Resolved
Vessel failed to give immediately notification to the nearest Coast Guard Marine Safety Office of a Hazardous Condition, as per 33 CFR 160.215.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 28 October 2015
Resolution: Coast Guard cleared deficiencies relating to the known hazard the vessel posed to the Port of New York during its transit into APM Terminal.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 13 August 2014 Resolved
Provide proof of properly operating main engine and start air system to the satisfaction of an attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2014
Resolution: Received Class survey report stating that the start air system is operating properly and the main engine is fully operational.
Engineering › Lubricating Oil Service System › Pump
Issued 13 June 2014 Resolved
Vessel must have a means to restore propulsion after the failure of an essential auxiliary. Following damage and subsequent failure to #2 ME L.O. pump vessel does not have redundancy of main L.O. system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2014
Resolution: Deficiency previously cleared by [name withheld], Activities Far East.

Casualty record · 10

14 June 2013Routine · role: Involved in a Marine Casualty · activity 4648001
22 November 2013Routine · role: Involved in a Marine Casualty · activity 4757548
21 January 2014Routine · role: Involved in a Marine Casualty · activity 4795591
27 December 2015Routine · role: Involved in a Marine Casualty · 1 injured · activity 5813209
11 April 2016Routine · role: Involved in a Marine Casualty · activity 5851821
25 July 2017Routine · role: Involved in a Marine Casualty · activity 6222072
26 June 2018Routine · role: Involved in a Marine Casualty · activity 6467602
18 September 2021Routine · role: Involved in a Marine Casualty · activity 7346143
28 December 2023Routine · role: Involved in a Marine Casualty · activity 7845022
13 August 2024Routine · role: Involved in a Marine Casualty · activity 7982959
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.