MAURY USCG vessel records
← All vessels

RTC 62

Built
2011
Last inspected
11 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 11 July 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2012–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX3683
1101489
Flag
UNITED STATES
Maury page id
psix-1101489

Documentation record

Registered dimensions (L × B × D)297.3 ft × 68.0 ft × 24.5 ft
Registered tonnagegross 5,153 / net 5,122
ITC dimensions (L × B × D)297.3 ft × 68.0 ft × 24.5 ft
ITC tonnagegross 4,533 / net 2,942
BuilderSENESCO MARINE · KINGSTOWN, RI, UNITED STATES · built 2011
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8347 - Dead Weight, Gross Ton
4533 - Convention (Subpart B), Gross Ton
5153 - Regulatory (Subpart C or D), Gross Ton
2942 - Convention (Subpart B), Net Ton
5122 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STEPHEN-SCOTT Towing Vessel · MISLE 92038 · 10 December 2013 · activity 4768962

Inspection history · 22

11 July 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182811
2 October 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8004367
26 September 2024 Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8004359
11 June 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932633
1 April 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166796
16 June 2020 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6977964
5 March 2019 Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6636360
6 November 2018 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6575418
14 February 2018 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6355219
17 March 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106444
16 March 2016 Internal Structural Exam · Drydock Exam · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5826217
30 April 2015 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5113748
26 March 2014 Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4823177
27 February 2014 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4806972
28 January 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4790449
10 December 2013 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4768962
2 December 2013 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4766210
30 November 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4493691
2 October 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4455321
7 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4336687
15 March 2012 MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4264074
26 January 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4232461

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 June 2024 Resolved
Fwd rake stbd side frame 3 and fwd rake port side frame 3 crop and renew. 46 CFR 31.10 (C)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 July 2024
Resolution: NDT satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2019 Resolved
The life buoy grab line shall be 3/8"-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The grab line on all eight life buoys were either severed or deteriorated. Replace all life buoy grab lines to original specification.
Action required: 705 - Other - as specified
Due 12 March 2019
Resolved 12 March 2019
Resolution: Replaced all life bouy grab lines.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2019 Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system which provides continuous indication of circuit status. The ground detection lights were inoperable and did not display continuous indication.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 5 March 2019 Resolved
For transfer operations between sunset and sunrise, deck lighting that adequately illuminates transfer operations is required. Deck lighting was inop around the transfer area. Do not conduct transfer operations between sunset and sunrise until cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: All deck lighting was repaired and operational at the time of re-inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 March 2019 Resolved
The last 1.0 meter of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be painted in sequence of red/yellow/red. The width of the red bands must be 0.1 Meter and the width of the yellow band must be 0.8 Meter and labeled with the word "VAPOR". The color scheme of the vapor line did not meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Vapor line was color coded IAW 46 CFR 39.2001 (h).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2019 Resolved
All passageways leading to living quarters, shall have two means of escape. Barge PIC was not able to open second means of escape.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2019
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 January 2014 Resolved
Due to extremely cold temperatures, vessel must satisfactorily complete the hydrostatic pressure testing of each loading arm and each transfer pipe system, including each metallic hose, at earliest opportunity but NLT 60 days. 33 CFR 156.710(c)(4)
Action required: 705 - Other - as specified
Due 28 March 2014
Resolved 27 February 2014
Resolution: Received email from company with copy of hydrostatic testing record of test carried out on 25FEB2014. All SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.