Records from 2011 to 2025. Most recent: inspection, 11 July 2025.
Documentation record
Registered dimensions (L × B × D)297.3 ft × 68.0 ft × 24.5 ft
Registered tonnagegross 5,153 / net 5,122
ITC dimensions (L × B × D)297.3 ft × 68.0 ft × 24.5 ft
ITC tonnagegross 4,533 / net 2,942
BuilderSENESCO MARINE · KINGSTOWN, RI, UNITED STATES · built 2011
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8347 - Dead Weight, Gross Ton
4533 - Convention (Subpart B), Gross Ton
5153 - Regulatory (Subpart C or D), Gross Ton
2942 - Convention (Subpart B), Net Ton
5122 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
11 July 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182811
2 October 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8004367
26 September 2024
Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8004359
11 June 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932633
1 April 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166796
16 June 2020
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6977964
5 March 2019
Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6636360
6 November 2018
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6575418
14 February 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6355219
17 March 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106444
16 March 2016
Internal Structural Exam · Drydock Exam · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5826217
30 April 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5113748
26 March 2014
Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4823177
27 February 2014
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4806972
28 January 2014
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4790449
10 December 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4768962
2 December 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4766210
30 November 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4493691
2 October 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4455321
7 June 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4336687
15 March 2012
MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4264074
26 January 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4232461
17 February 2011
MARPOL Annex I Examination · Construction Oversight · MARPOL Annex VI Survey · Initial Certification · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3947433
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 June 2024
Resolved
Fwd rake stbd side frame 3 and fwd rake port side frame 3 crop and renew.
46 CFR 31.10 (C)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 July 2024
Resolution: NDT satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2019
Resolved
The life buoy grab line shall be 3/8"-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds.
The grab line on all eight life buoys were either severed or deteriorated. Replace all life buoy grab lines to original specification.
Action required: 705 - Other - as specified
Due 12 March 2019
Resolved 12 March 2019
Resolution: Replaced all life bouy grab lines.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2019
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system which provides continuous indication of circuit status.
The ground detection lights were inoperable and did not display continuous indication.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 5 March 2019
Resolved
For transfer operations between sunset and sunrise, deck lighting that adequately illuminates transfer operations is required.
Deck lighting was inop around the transfer area. Do not conduct transfer operations between sunset and sunrise until cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: All deck lighting was repaired and operational at the time of re-inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 March 2019
Resolved
The last 1.0 meter of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be painted in sequence of red/yellow/red. The width of the red bands must be 0.1 Meter and the width of the yellow band must be 0.8 Meter and labeled with the word "VAPOR".
The color scheme of the vapor line did not meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Vapor line was color coded IAW 46 CFR 39.2001 (h).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2019
Resolved
All passageways leading to living quarters, shall have two means of escape.
Barge PIC was not able to open second means of escape.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2019
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 January 2014
Resolved
Due to extremely cold temperatures, vessel must satisfactorily complete the hydrostatic pressure testing of each loading arm and each transfer pipe system, including each metallic hose, at earliest opportunity but NLT 60 days. 33 CFR 156.710(c)(4)
Action required: 705 - Other - as specified
Due 28 March 2014
Resolved 27 February 2014
Resolution: Received email from company with copy of hydrostatic testing record of test carried out on 25FEB2014. All SAT.