Records from 2011 to 2026. Most recent: inspection, 18 May 2026.
Documentation record
Registered dimensions (L × B × D)157.0 ft × 48.0 ft × 11.3 ft
Registered tonnagegross 825 / net 561
ITC dimensions (L × B × D)157.0 ft × 48.0 ft × 11.3 ft
ITC tonnagegross 1,095 / net 328
BuilderGULF ISLAND LLC · HOUMA, LA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKIN, WV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1095 - Convention (Subpart B), Gross Ton
825 - Regulatory (Subpart C or D), Gross Ton
328 - Convention (Subpart B), Net Ton
561 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
18 May 2026
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8376532
24 February 2026
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8298954
6 August 2025
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8204449
8 July 2025
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8178537
5 February 2025
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8075449
5 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7996887
23 August 2024
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7987517
7 May 2024
Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7908232
6 May 2024
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7907623
16 February 2024
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7866554
16 February 2024
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7867769
13 January 2024
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7849883
13 January 2024
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7849897
23 October 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7813007
18 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7381914
8 April 2021
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7171031
15 September 2020
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7064155
23 February 2020
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6914632
5 February 2019
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6638094
27 June 2018
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6463951
5 February 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6351695
19 January 2016
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5799518
31 October 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5758229
28 September 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5743662
14 May 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4858766
31 May 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4333411
26 April 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4296552
13 March 2012
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4389332
7 March 2011
DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3961478
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 24 February 2026
Resolved
Alarms must have a means to test actuation at each operating station. Unable to test low hydraulic steering fluid and Low fuel level on day tank. Install means to test these alarms IAW company TSMS.
46CFR143.230(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2026
Resolved 5 March 2026
Resolution: Received objective evidence of satisfactory repairs from TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 February 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessels starboard generator failed. Diagnose issue and repair to the satisfaction of an attending Marine Inspector.
46 CFR 143.205(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2025
Resolution: Received close out letter from TPO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel reported a loss of propulsion on the starboard wheel. Repairs to be completed to the satisfaction of the attending marine inspector.
The vessel is authorized to transit to National Maintenance Paducah at mile marker 930 of the Ohio river for repairs. Vessel must submit a transit plan to MSU Paducah and Sector Ohio Valley for approval prior to transit.
The vessel's TPO has the option to clear this deficiency with notification to the local OCMI within 72-hours in accordance with CG-CVC Policy Letter 17-10.
46 CFR 143.205(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2024
Resolution: Vessel provided objective evidence of a wire wrapped around the prop. Removed and tested all propulsion, reported working as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 February 2024
Resolved
On 15 February 2024 at approx. 19:15 the vessel experienced a port turbocharger malfunction while maintaining station at the Rockport Power Plant fleet at mile 745.5 Ohio River RDB. Vessel operator required to repair/replace port turbocharger before placing the vessel back into service. Contact Coast Guard duty marine inspector at [phone withheld], when repairs are completed.
TPO can verify repairs and provide documentation to the OCMI listed above to clear deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 January 2024
Resolved
On 12 January 2024 at approx. 20:45 the vessel
experienced a port generator burnout while maintaining
station as a high water safety contingency at the
Rockport Power Plant fleet at mile 745.5 Ohio River RDB.
Vessel operator required to repair generator before
placing the vessel back into service and verify the
required number of portable fire extinguishers are on
board. Contact Coast Guard duty marine inspector at
[phone withheld], when repairs are completed.
TPO can verify repairs and provide documentation to the
OCMI listed above to clear deficiency.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2024
Resolved 15 January 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Civil Liability for Oil Pollution Damage Cert.
Issued 23 October 2023
Resolved
Requirement to establish and maintain evidence of financial responsibility. The COFR Operator of a vessel must establish and maintain (or cause to be established and maintained) evidence of financial responsibility acceptable to the Director using any one of the methods specified in § 138.110, in an amount equal to or greater than the total applicable amount determined under § 138.100 and, in the case of a financial guarantor, as further provided under § 138.110(c)(2) (aggregation of total applicable amounts). The evidence of financial responsibility required by this paragraph must be—
(1) Established as of the date they become a responsible party; and
(2) Continuously maintained for so long as they remain a responsible party.
Vessel’s COFR expired on January 5th, 2023. Provide documentation of COFR renewal.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 24 October 2023
Resolution: Received proof of COFR renewal.