Inspection history · 23
13 February 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8306478
2 May 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8127504
29 January 2024
Deficiency Check · COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7857464
26 January 2023
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7627359
31 October 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7586583
9 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7348803
18 October 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7338157
15 September 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7059797
18 August 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7036484
30 May 2019
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6704735
20 March 2017
Industry Initiated Exam · Administration
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6108716
22 February 2017
Administration
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6093505
19 September 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4445530
31 May 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4333411
5 September 2007
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3049486
20 November 2006
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2825393
24 March 2005
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2318911
5 November 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 423865
31 August 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 420310
19 December 1995
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 703624
12 October 1995
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 204295
29 September 1994
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 703625
9 September 1994
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 20750
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2025
Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be fitted with isolation valves. Fuel oil return lines at the fuel tank, for the main engine's and generator's, do not have any isolation valves. Install isolation valves to the satisfaction of an attending Marine Inspector.
46 CFR 143.250(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 5 May 2025
Resolution: Received photgraphic evidence of satisfactory repairs. Uploaded to def docs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 March 2024
Resolved
The control panel includes: (iii) Visual alarm alarms to identify the zone or zones of origin of the fire. During operational test of the 2nd deck smoke detector, the fire panel showed an alarm at zone 1. The panel listed the 2nd deck as zone 2. Test all zones and re-label.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 15 March 2024
Resolution: Received statement from [name withheld] attesting to proper fire zone locations matching detectors feeding fire panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 March 2024
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Starbord, forward engine room hatch cover was bent and not forming a proper watertight seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 15 March 2024
Resolution: Received photos showing proper seal on e/r deck hatch.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2024
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. Portable fire extinguisher in 2nd deck compartment was installed on a j-bracket, which is not suitable for the type and size.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 15 March 2024
Resolution: Received photo of new, proper bracket for fire extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 March 2024
Resolved
Each storage container containing a work vest must be marked “WORK VEST”. Work vests and lifejackets were found to be stored together in same cabinet on 2nd deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 15 March 2024
Resolution: Received photo of work vests stored seperately from PFDs, and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 October 2022
Resolved
The water light must be attached by the lanyard with a corrosion-resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip must have a strength of at least 22.7 kilograms (50 pounds). Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 1 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2021
Resolved
Port MDE has a cracked cylinder Liner. Engine tagged out OOC. Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:
(1) Be maintained to ensure proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 9 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021
Resolved
Hydraulic Steering hoses outer casing cracked and brittle exposing inner core of hose to weather. Replace hydraulic hoses in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 21 October 2021
Resolution: Hoses replaced. System tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021
Resolved
Steering gear rudder stock bracket missing bolts. Ensure bolts replaced in accordance with manufactuers instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 21 October 2021
Resolution: Bolts replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2021
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 21 October 2021
Resolution: Metal chain installed to secure BV.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention - High Bilge Levels. Unable to test high bilge level alarm due to no power at the alarm panel. Prove proper operation of high bilge level alarm to the satisfaction of the attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 August 2020
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting located in compressor room and engine room were not illuminating. Prove proper operation of the emergency lighting to the satisfaction of the attending CG marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 August 2020
Resolved
Each towing vessel must be equipped with navigation lights. PORT side light (red) and stern light were not illuminating. Prove proper operation of all navigation lights to the satisfaction of the attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2020
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. Vessel only had 06 lifejacket on board and carriage required IAW COI is 12 lifejacket. Vessel is restricted to only 06 total persons allowed on board until proper prove of the total 12 lifejackets are on board to the satisfaction of the attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 August 2020
Resolved
The original COI must be framed under glass or other transparent material and posted in a conspicuous place on board the towing vessel. Original COI not on board. Prove original COI is posted on board to the satisfaction of the attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 August 2020
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. Did not conduct drills due to underway restrictions (deficiencies). Conduct underway drills to the satisfaction of the attending CG marine inspector prior to operating the vessel.
Action required: 705 - Other - as specified
Resolved 15 September 2020
Resolution: Conducted MOB drill to satisfaction of CG marine inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 27 August 2020
Resolved
The owner or managing operator must implement a health and safety plan. "Safe use and storage of hazardous materials and chemicals" is missing from the training requirements within the health and safety plan. Prove to the satisfaction of the CG marine inspector that said section is added to the health and safety plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 2 September 2020
Resolution: Cleared to the satisfaction of the CG marine inspector.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 31 August 1998
Resolved
SHIPS FOG BELL WAS MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Markings/Placards › Oil Discharge Placard
Issued 31 August 1998
Resolved
PROHIBITED DISCHARGE WARNING PLACARD WAS MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 August 1998
Resolved
VESSEL DID NOT HAVE AN ADEQUQTE MAENS OF REMOVING OILY WASTE FROM BILGE.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Markings/Placards › Official Number (US)
Issued 31 August 1998
Resolved
OFFICIAL NUMBER NOT VISABLE ON VESSEL.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Markings/Placards › Warning Signs
Issued 31 August 1998
Resolved
TOW LIGHTS WERE NOT WORKING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 31 August 1998
Resolved
NOT THE PROPER NUMBER OF PFD'S FOR EACH PERSON ABOARD.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 August 1998
Resolved
PFD'S ARE NOT READILY ACCESSIBLE FOR CREW.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 31 August 1998
Resolved
RETROREFLECTIVE MATERIAL MISSING FROM PFD'S.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Markings/Placards › Vessel Number (state)
Issued 31 August 1998
Resolved
NAME AND HAILING PORT WAS NOT DISPLAYED ON VESSEL.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Certificates/Documents › FCC SSL
Issued 31 August 1998
Resolved
FCC RADIO LICENSE WAS MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 31 August 1998
Resolved
MARINE CHARTS MISSING FROM VESSEL.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 August 1998
Resolved
COAST GUARD LIGHT LIST WAS MISSING FROM VESSEL.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Logs/Records › Logbook (official)
Issued 31 August 1998
Resolved
VESSEL TEST AND INSPECTION LOG WAS MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 31 August 1998
Resolved
LOCAL NOTICE TO MARINERS MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 August 1998
Resolved
MAGNETIC COMPASS OR SWING METER MISSING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 August 1998
Resolved
NAVIGATION LIGHTS NOT WORKING.
Condition: Unknown
Due 1 October 1998
Resolved 5 September 2007