Records from 2014 to 2022. Most recent: inspection, 1 December 2022.
Inspection history · 16
1 December 2022
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7604800
14 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7431332
29 January 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7387602
26 January 2022
COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7384003
3 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7188106
21 July 2020
COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7008540
28 July 2019
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6753913
18 July 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6476826
13 July 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6478066
6 May 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6407074
3 May 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404419
3 May 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404538
1 July 2017
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6184241
7 August 2016
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5953854
7 June 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5888530
26 March 2014
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4819660
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs identified 04 cargo ullage opening gaskets which were significantly deteriorated as well as twisted and improperly installed.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 April 2022
Resolution: Received satisfactory DNV Class Society documentation attesting to the proper replacement and subsequent testing of COT ullage gaskets.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 7 June 2016
Resolved
On a tankship, each cargo tank must be equipped with an overfill must activate an audible and visible alrm so that it can be seen and heard on the vessel where cargo transfer is controlled. Tank overfill alarm failed to provide visible indication as required. 33CFR155.480(B)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2016
Resolution: Witnessed satisfactory operational test of overfill light and audible alarm from deck.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 7 June 2016
Resolved
Navigational systems and equipment to perform functional requirements of regulations 19 & 20 shall confrom to performance standards not inferior to those adopted by Organization. Captain reported that speed log was not operable while vessel was drifting prior to entering port. Technician onboard repaired system and proved functionality of system prior to completion of exam. SOLAS(14)V/18.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 June 2016
Resolution: Rcvd third party technician report attesting to the proper operation of the speed log.