← All vessels
HUEMUL
HUEMUL is a 2008 tank ship. The Coast Guard has recorded 22 inspections since 2017, most recently in February 2025, along with 9 deficiencies and 1 operational control.
Records from 2017 to 2025. Most recent: inspection, 26 February 2025.
- Built
- 2008
- Last inspected
- 26 February 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9371775 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EUB7
1104698
Flag
PANAMA
—
Maury page id
psix-1104698
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2017–2025)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13666 - Convention (Subpart B), Gross Ton
6687 - Convention (Subpart B), Net Ton
22062 - Dead Weight, Metric Ton
29414 - Displacement, Metric Ton
6687 - Convention (Subpart B), Net Ton
22062 - Dead Weight, Metric Ton
29414 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
26 February 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8083106
20 May 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7455111
18 May 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7453858
2 May 2022
PSC B · COC-CHEM & TVE Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7440868
3 September 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7303444
14 July 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7256375
19 May 2021
COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7198057
6 February 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7136811
15 May 2020
COC-CHEM Annual
Type not classified · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6949322
3 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6802989
25 July 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6763257
25 July 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6766246
23 April 2019
Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6668409
19 March 2019
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6638001
13 November 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6579632
29 October 2018
Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6570619
31 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6347328
19 January 2018
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS III Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6340263
2 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6137349
25 April 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6132567
25 April 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6132578
26 January 2017
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6072048
Deficiency record · 9
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 19 May 2021
Resolved
The comapany and ship shall comply with the requirtements of the ISM Code. The comapny should establish procedures to ensure that the e ship is mantianed in conformity with the provisions of the relevant rules and regiualtions which may be eatablished by the company. In meeting these requirements , the comapny should enaure that; inspectionss are held at appropairate intervals , any non coformity is reported, appropriate corrective action is taken, and records of these activities are maintianed. In accordance with the vessel's PMS [381.01,850.9508, and 850.95.03] Electrical installations on the deck are to be inspected every 90 days. Addtionally, tank gauging is to be inspected every 30 days. As delineated in the following deficieciencies, the vessel's comapny failed to ensure that maintenance and inspections of electrical installations, gauging systems, and deck water spray were being held at appropraite intervals. Note: comapny implimented a new PMS system on 11May, but vessel's crew was unable to provide records of prevention PMS records since the company's aquireing of the vessel in Jan21.
An internal audit, focusing on maintenance and inspections, is required within 30 days.
74SOLAS(14) IX/5.1
ISM Code 10.1
ISM Code 10.2
50C
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 19 May 2021
Resolved
Means shall be provided for montiroing ullage spaces contiaing a gas blanket to ensure that the correct atmosphere is being maintained. When overheating or overcooling could result in a adangerous condition, an alarm system wahich monitirs, the cargo temperature shall be provided. PSCO obseraved instrumentation on the cargo control room cargo monitoring system were inoperable. The system was producing a "Failure" code for the ullage, temp., and pressure. Accurate readings were not provided.
74SOLAS(14) VII/10.1
IBC 9.1.3.4
IBC 7.1.5.4
15AC
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2021
Resolved
Electrical equipment, cables, and wiring shall not be installed in the hazardous locatons unless it conforms with the standards not inferior to those acceptable to the organization. PSCO observed multiple electrical installations susceptaible to mechanical damage. The electircal lighting above #6 Center port is cracked. Note: light is in a hazardous locaton. Glan packing in mutliple electrical installations are losse rendering electrical not explosion proof.
74SOLAS (14) VII/ 10.1
IBC 10.1.4
40AC
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 May 2021
Resolved
A water-spray system of sufficient capacity shall be provided to blanket effectively the area surrounding the loading manifiold, the exposed deck piping associated with product handling , and the tank domes. PSCO observed 2 hooles in the water-spray systme piping. Each hole was two to three inches wide. In addition, multiple noxzzle heads were clogged cuasing insufficient coverage.
74SOLAS (14) VII/ 10.1
IBC 15.8.29
40ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 May 2021
Resolved
Each vessel vapor connection flange must have a permanently attached .05 inch diameter stud atleast 1.0 inch long projecting outward from the flange face. PSCO observed vapor connection flange stud projecting inward.
46CFR39.2001(e)
40ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 25 July 2019
Resolved
the company and the ship shall comply with the requirements of the ISM Code. The company shouldensure that the polict is implemented and maintained at all levels of the organization, both ship-based and shore-based. Vessel unaware of transfer procedures and failed to follow procedures and arrangement manual as well asthe cargo operations plan from the integrated managment systems which caused the cargo tank to over fill and discharge oil. Recommend ISM Audit.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 March 2019
Resolved
SELF-CLOSING FIRE DOORS OF THE SAME FIRE INTEGRITY STANDARDS SHALL BE FITTED IN THE ENCLOSURE.
THE SELF-CLOSING FIRE DOORS LEADING TO THE MEANS OF ESCAPE FROM THE MACHINERY SPACE OF CATAGORY A WERE ALL FOUND TO BE MISSING THE LOCK, LEAVING A HOLE IN THE DOOR COMPROMISING THE A-60 FIRE-BOUNDARY RATING. 74SOLAS(14)II-2/13.4.2.1.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 29 October 2018
Resolved
01 - 02134 - To discharge ballast water into the water of the United States, the master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2030(a)(3), or ballast with water from a U.S public water sustem, according to the schedule in paragraph (b) of this section. Subject vessel, of a keel laid date 09OCT06 and ballast water capacity of 9610.90 meters cubed, is past its compliance daate per the implementation schedule in 33CFR151.2035(b). Currently vessel's installed BWTS is inoperable. - 33CFR151.2035
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 19 January 2018
Resolved
Conditions of the ship and its equipment shall be maintained to conform. PSCO noted approximitly 10 nozzles not providing water as designed. IBC 1.5.3 40 a/c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.