MAURY USCG vessel records
← All vessels

ECO EVOLUZIONE

ECO EVOLUZIONE is a 2010 tank ship. The Coast Guard has recorded 50 inspections since 2016, most recently in August 2022, along with 14 deficiencies — 1 with no resolution recorded — and 11 operational controls.

Records from 2016 to 2022. Most recent: inspection, 14 August 2022.

Built
2010
Last inspected
14 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 August 2022
…with no type recorded25
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9471123
1107521
Flag
LIBERIA
Maury page id
psix-1107521

Documentation record

Tonnage as PSIX records it22618 - Dead Weight, Metric Ton
37108 - Displacement, Metric Ton
6893 - Convention (Subpart B), Net Ton
22977 - Regulatory (Subpart C or D), Gross Ton
6893 - Regulatory (Subpart C or D), Net Ton
22977 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MATTHEW K Towing Vessel · MISLE 10093 · 28 June 2021 · activity 7240926ORION IH-2201 Freight Barge · MISLE 43147 · 28 June 2021 · activity 7240926MISS AIMEE Towing Vessel · MISLE 196723 · 28 June 2021 · activity 7240926ANDREW K Towing Vessel · MISLE 349103 · 28 June 2021 · activity 7240926GAS AQUARIUS Tank Ship · MISLE 1485492 · 28 June 2021 · activity 7240926

Inspection history · 50

14 August 2022 PSC B · COC-GAS Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7531434
4 August 2022 COE-Administrative
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7524586
4 August 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7524794
2 August 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7522929
18 June 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7480843
17 May 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7452890
14 May 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7450443
17 March 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7413595
15 March 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7412081
22 December 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7373900
7 September 2021 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7306235
27 August 2021 PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7297969
26 August 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7295968
28 June 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7240926
30 May 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7210257
23 May 2021 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7199130
10 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7153807
4 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7150214
4 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7150242
30 January 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7136759
26 January 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7131308
20 January 2021 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7124429
20 January 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7128499
19 January 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7127056
12 August 2020 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7030852
11 August 2020 PSC B · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7024054
1 August 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7021672
31 July 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7020746
14 April 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6939160
9 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6937493
8 January 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6885446
8 January 2020 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7014251
3 November 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6848590
2 November 2019 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6844496
2 November 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6847546
16 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6627054
10 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6724355
9 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6622891
18 November 2018 Administrative Inspection · COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579448
3 October 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6554659
3 October 2018 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6554660
29 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6551475
28 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6550657
9 August 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6499754
1 September 2017 COE-Administrative · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6254395
1 September 2017 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6256780
11 August 2017 COE-Offshore
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6237544
26 July 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6219406
21 July 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6216062
1 February 2016 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5803469

Deficiency record · 14

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 14 August 2022 Resolved
Recommend internal safety audit on board to verify whether safety activities comply with the safety management system. The crew, with Captain's knowledge, are using trash bag with duct taped tube to capture cargo vapor at desk tank sampling point. Cargo vapor is then used to test fixed gas detection sampling points in motor room, compressor room and void spaces. Captain acknowledged this is not an approved procedure. Prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2022
Resolved 14 August 2022
Resolution: Class, Llyod's Register, supplied report acknowledging testing procedure and attesting to capability of gas detection system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 14 August 2022 No resolution recorded
Testing should be carried out at regular intervals. Suitable equipment and span gas for this purpose should be carried on board. Span gas bottle are too small to test fixed gas detection sampling points in motor room, compressor room and void spaces.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 August 2022 Resolved
The container shall be marked with date last serviced. Starboard side life raft did not have an updated marking with recent service date.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 August 2022
Resolved 14 August 2022
Resolution: Ship's crew placed marking into service on liferaft container.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 August 2021 Resolved
The deck water spray system should be capable of covering all areas mentioned in 11.3.1 with uniformly distributed water-spray of at least 10 l/m2 per min... Vessel had numerous clogged sprinkler heads on cargo tank domes #1 and #3 causing ineffective coverage. This deficiency was satisfactorily rectified on board in presence of PSCO's. - IGC Code 93/ 11.3.2
Action required: 17 - Rectify deficiencies prior to departure
Due 27 August 2021
Resolved 27 August 2021
Resolution: Vessel crew was able to satisfactorily clear out clogged sprinkler heads prior to PSCO's departure.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 August 2021 Resolved
If cargo control room is designed to be a gas-safe space, instrumentation should... be designed to prevent any escape of gas into the atmosphere of that space. Gas detection cabinet had a fan installed. - IGC Code 3.4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 7 September 2021
Resolution: Class report issued. Wooden pallets were placed beneath cylinders.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2021 Resolved
Cylinders must always be secured and when not in use, must be stowed in a rack. 03 oxygen and 03 acetylene cylinders were found stowed on the deck, not in a rack. - 46 CFR 147.60
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 7 September 2021
Resolution: The fan on cabinet cover (incl. electrical cables) was removed, all holes were blinded with thin steel plates and rubber gasket on this cabinet for the panel to be gastight. The arrangement considered satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 May 2021 Resolved
07126-Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces. PSCO found oil leaks and excessive pooling of oil on and around the main engine #6 cylinder.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2021
Resolved 30 May 2021
Resolution: Vessel submitted class report attesting to repairs of #6 cylinder safety relief valve.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 23 May 2021 Resolved
14199-The condition of the ship ands its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting and unreasonable threat of harm to the marine environment. PSCO observed a patch on the water supply line on the gravity tank for the Oily Water Separator. The patch was removed by the crew, revealing a pin hole leak in the line.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2021
Resolved 30 May 2021
Resolution: Vessel submitted class report attesting to replacement of T connection on OWS line.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 August 2020 Resolved
The company should ensure that the appropriate corrective action is taken for any reported non-conformity. The ship reported a malfunctioning relay module of the burner controller on the Inert Gas Generator on February 25th 2020. The relay module was not ordered until July 16th 2020. The hold spaces have not been inerted as required in the ICG code 9.2.1 since January 7th 2020. There were no additional mitigating safety measures implemented for the ship to follow and maintain an inert atmosphere in hold spaces. Also, the crew was unable to provide documentation attesting to the proper notification to the vessel's classification society in regards to the malfunctioning relay module of the burner controller on the Inert Gas Generator. Deficiencies #2 through #4 make up a systematic breakdown of the vessel's Safety Management System. An external audit is required. 74 SOLAS (14) IX/3.1 ISM 10.2.3
Action required: 30 - Ship detained
Resolved 14 August 2020
Resolution: External audit was received and accepted.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 11 August 2020 Resolved
The condition of the ship and it's equipment should be maintained to conform with the provisions of the Code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The Inert Gas Generator oxygen content meter cannot operate properly without bypassing the flow regulator for the sample gas tubing. Subsequently the hold spaces have not been inerted IAW IGC Code 9.2.1 since 07JAN2020 as per their Dry Inert Gas Generator Operations Log. 74 SOLAS (14) VII/13.1 93 IGC 1.5.3.1
Action required: 30 - Ship detained
Resolved 14 August 2020
Resolution: Vessel receieved parts and system was operating properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2020 Resolved
Electrical equipment, cables and wiring should not be installed in hazardous locations unless it conforms with the standards. Bonding cabling for lighting near Cargo Tank #3 was missing. 74 SOLAS (14) VII/13.1 93 IGC 10.1.4
Action required: 10 - Deficiency Rectified
Resolved 11 August 2020
Resolution: Bonding strap was fixed on the spot.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 11 August 2020 Resolved
The gas detection equipment should be capable of sampling and analyzing for each sampling head location sequentially at intervals not exceeding 30 minute. The fixed gas detection sampling heads located at the top and bottom of the cargo compressor room were equipped with valves which would allow for isolation of the sampling heads. Due to the arrangement the sampling heads did not allow for each sampling head location to be sequentially analyzed at intervals not exceeding 30 minutes per the IGC code. 74 SOLAS (14) VII/13.1 93 IGC 13.6.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2020
Resolution: Procedures for gas detection system were posted in the appropriate areas and training was provided to the crew.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 9 August 2018 Resolved
06105-Atmosphere testing instruments- Detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column f in the table of chapter 19. PSCO observed fixed gas detection not correctly calibrated and no reading concurrent with span gas levels. SOLAS 74 a 2014 Cons. CH VII Reg 12 IGC 1993 ed 13.6.1 a-Prior to Cargo
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 August 2018
Resolution: Witnessed sat calibration and operation of fixed gas detection prior to disembarking the vessel
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 August 2018 Resolved
01305-log-books/compulsory entries- changes in set pressures should be recorded in the ship log and a sign posted in the cargo control room, if provided, and at each relief valve, stating the set pressure. Vessel has not been logging MARV changes from sea .25 bar to harbor condition .45 in ships logbook. SOLAS 74 a 2014 Cons. CH VII Reg 12 IGC 1993 ed 8.2.7 40a
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2018
Resolution: PSC NOLA received class report from LR satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.