Records from 2011 to 2024. Most recent: inspection, 23 October 2024.
Inspection history · 7
23 October 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8020289
1 September 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7040765
26 September 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6009459
21 September 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5996588
8 June 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4340724
8 June 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4349797
8 September 2011
PII Safety Exam · Ballast Water Examination · COE-Dockside · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4132758
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 September 2016
Resolved
Oily water separator was inopperable after multiple attempts to test it.
MARPOL Annex I Reg. 14.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2016
Resolved 26 September 2016
Resolution: MSU Baton Rouge received class report regarding deficiency. PSCO attended vessel to verify proper operation.
Documentation › Logs/Records › Oil Record Book
Issued 21 September 2016
Resolved
2230-- Any failure of the oil filtering equipment shall be recorded in the Oil Record Book Part 1. Chief Engineer stated that on July 9 2016 he discovered the OWS had broken filters during routine maintenance that needed replaced. Inoperable OWS was not logged into Oil Record Book. MARPOL Annex I Reg. 17.5
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Attending PSCO verified the entry into ORB during exam.
Construction/Loadline › Structures › Door
Issued 21 September 2016
Resolved
0745--The following fire protection systems shall be kept in good order so as to ensure required performance if a fire occurs.(1.) structural fire protection, including fire resisting divisions, and protection of openings and penetrations in these divisions. PSCO discovered that the boundry door to the fuel oil purifier room would not properly close. 74SOLAS14 II/14.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2016
Resolved 26 September 2016
Resolution: MSU Baton Rouge received class report regarding deficiency. PSCO attended vessel to verify proper operation.
Fire Fighting › Combustible Materials › Insulation
Issued 21 September 2016
Resolved
0750--Means shall be provided to control leaks of flammable liquids. PSCO discovered excessively oil soaked lagging on port side fuel oil service pump piping in engine room. 74SOLAS14 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: PSCO verified that the lagging was replaced.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 8 September 2011
Resolved
9900 - Other (not clearly hazardous) Vessel has no VGP, master was unaware of VGP and there is no record of submission of eNOI. Submit confirmation of receipt of VGP onboard to the Coast Guard and submit eNOI to EPA immediately. Clean Water Act, 40 CFR 122
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 9 September 2011
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. Master emailed copies of VGP and submission acceptance from the EPA for eNOI.