Records from 2006 to 2025. Most recent: inspection, 2 October 2025.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 9.0 ft
Registered tonnagegross 117 / net 94
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLA FORCE SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it117 - Simplified, Gross Ton
94 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
2 October 2025
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8249274
19 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8213635
1 July 2025
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8171985
18 June 2020
Initial Certification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6979977
15 May 2020
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6968658
15 February 2019
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6626413
15 February 2019
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6627796
14 February 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6648654
26 September 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6009459
29 April 2014
Deficiency Check · MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4846341
23 December 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4774189
13 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4151022
25 June 2010
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3776195
14 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362984
16 March 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2900918
5 September 2006
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2769952
30 August 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2763854
24 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2758861
24 August 2006
MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2760173
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 August 2020
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials insofar as practicable. Oil/fuel located in the bilge between fuel tanks and generators. Remove flammable/combustible liquid accumulation to satisfaction of attending surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2020
Resolved 7 August 2020
Resolution: Cleared by TPO
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 August 2020
Resolved
To stop the flow of fuel in the event of a ire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Port side remote fuel cutoff valve is inoperable. Repair to satisfaction of attending surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2020
Resolved 7 August 2020
Resolution: Cleared by TPO
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 August 2020
Resolved
Emergency lighting must be provided for all crew working and living areas. Engine room emergency light inoperable. Repair/replace to satisfaction of attending surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2020
Resolved 7 August 2020
Resolution: Cleared by TPO
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 August 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Engine high cooling water temperature alarm in engine room is continually activated although water temperature is within safe parameters. Troubleshoot & repair alarm, provide technician's report to TPO and USCG.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2020
Resolved 7 August 2020
Resolution: Cleared by TPO