Records from 2011 to 2024. Most recent: inspection, 17 June 2024.
Inspection history · 14
17 June 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7936579
10 December 2021
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7365904
8 December 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364946
2 March 2020
Ballast Water Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6913073
15 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6479907
15 November 2017
PII Safety Exam · ISPS II Exam · COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6302460
29 March 2016
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5841981
29 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5842953
28 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5841909
15 March 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5833398
23 May 2014
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4859719
22 May 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4877135
13 May 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4306556
7 July 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4072762
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 15 November 2017
Resolved
0750-Fire Prevention-Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the double bottoms, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. Vessesl’s MDO service and MDO settling tanks quick closing valves were blocked open-SOLAS 74 (14 Cons.) II-2/4.2.2.3.4
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 15 November 2017
Resolution: Vessel Crew removed block from quick closing valve.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 15 November 2017
Resolved
0735-Personal Equipment-Fire fighter outfits shall protect the skin from the heat radiating from the fire and from burns and scalding by steam. 01 Fire fighting outfit had tear through protective Material-SOLAS 74 (14 Cons.)II-2/10.1.1 FSS Code 3.2.1.1.1
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 15 November 2017
Resolution: Vessel crew replaced fire fighter outfit with a spare.