Records from 2023 to 2026. Most recent: inspection, 19 August 2026.
Inspection history · 15
19 August 2026
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8467999
27 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8340245
16 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8269177
9 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8250170
2 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8225179
26 July 2025
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8208085
25 July 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8194237
5 July 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8175928
10 May 2025
Canadian Vsl Safety Exam (D9 only) · PSC B
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8131888
24 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8118673
25 March 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8099583
17 September 2024
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8008447
27 February 2024
Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7870764
2 November 2023
PSC A · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7809067
7 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7809027
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 May 2025
Resolved
The integrity of a stairwell shall br maintained by "A" class doors at every level. The doors shall be of self closing type.
Each self closing door in the stairtower at the upper deck, poop deck, boat deck, and captain's office deck would not fully self close. Crew adjusted all door's closing devices to fully close to meet regulation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2025
Resolved 10 May 2025
Resolution: Crew adjusted all door's closing devices to fully close to meet regulation.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 17 September 2024
Resolved
If a vessel's voyage is less than 96 hours, then the vessel must submit an NOA before departure but at least 24 hours before arriving at the port or place of destination. While vessel was en route from Meldrum Bay, Canada to Bay City, MI, a voyage of less than 96 hours, the vessel submitted their ENOA to the National Vessel Movement Center on September 17, 2024 @ 14:55 GMT (10:55 EST) with an ETA of September 17, 2024 @ 16:00 EST. Additionally, on September 17, 2024, when Port State Control Examiners were able to screen the vessel's NOA, the vessel was seen to be already in U.S. Waters in process of docking in Bay City, MI. Vessel arrived in Bay City, MI with only 6 hours notice.
33 CFR 160.212(4)(ii)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 September 2024
Resolved 17 September 2024
Resolution: Deficiency was rectified on the spot.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 November 2023
Resolved
The routine maintenance of the oily water separating equipment and the bilge alarm must be clearly defined by the manufacturer in the associated operating and maintenance manuals. All routine and repair maintenance must be recorded.
PSC Examiners found the piping and valves bewteen the oily water separator and overboard discharge to be disassembled, preventing the system from being tested or operating as designed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2023
Resolved 2 November 2023
Resolution: Received a Letter of Dispensation from Class.