Inspection history · 29
9 June 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8156048
19 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8132039
24 February 2025
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8083997
29 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7989515
27 June 2024
Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7943528
22 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7704583
21 July 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7512690
15 June 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7568076
1 June 2021
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7205686
28 December 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7117010
20 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6544553
4 September 2018
Explosive Handling Operation-Commercial
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6542434
6 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6436786
31 May 2016
Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5893073
9 September 2015
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5720656
9 May 2013
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4586400
3 May 2013
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586352
21 March 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976181
14 April 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3716409
23 March 2010
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701498
14 March 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2602619
26 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2256251
14 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2168646
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978356
19 May 2003
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1879884
21 November 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1709176
16 March 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 24555
15 November 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 70306
6 November 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 111619
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 May 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. MI observed leaking fuel piping connection in engine room at fuel transfer pump. Clean accumulated diesel and repair connection prior to using fuel transfer pump. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2025
Resolved 20 May 2025
Resolution: Operator provided statement attesting to tightening of fitting and application of thread sealant. Confirmed no additional leaks.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2025
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with...33 CFR part 84 as appropriate to its area of operation. Vessel does not have appropriate day shapes on board vessel. 46 CFR 140.720
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 20 May 2025
Resolution: Operator provided photograph of dayshapes onboard vessel
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2025
Resolved
Each EAP education program must include at least the following elements... display and distribution of the employer's policy regarding drug and alcohol use in the workplace. MI found company drug and alcohol policy on board to be dated in 1999, with old chemical testing frequencies listed. Place new company policy on board vessel. 46 CFR 16.401(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 5 June 2025
Resolution: Received updated company policy. Correct testing percentages listed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 May 2025
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. Emergency instructions posted do not cover all required items. Missing provisions include: Flooding, heavy weather, taking action relative to tow, loss of propulsion/steering/control, and management of non-crew. 46 CFR 140.405(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 20 May 2025
Resolution: Operator updated station bill to include missing provisions.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 May 2025
Resolved
A vessel must be operated in accordance with applicable
laws and regulations and in such a manner as to afford
protection against hazards to life, property and the
environment. Vessel had an excessive amount of diesel in
the bilge due to leaking fuel piping. 46 CFR 140.205(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 May 2025
Resolved 20 May 2025
Resolution: Operator provided photographs of cleaned bilge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2024
Resolved
All fire hoses must be inspected for excessive wear, and subjected to a test pressure equivalent to the maximum service pressure. All fire hoses which are defective and incapable of repair must be destroyed. Vessel was found with hose that was leaking at the connection with the fire station making it defective. Vessel Captain destroyed the hose in the presence of a MI and replaced the hose with a new one, and was satisfactorily tested.
46 CFR 142.240 (a)(7)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2024
Resolution: Vessel replaced fire hose during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2024
Resolved
Nature of inspection: The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable statutes and regulations for such vessels. The inspection will include inspections of the structure, pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire detecting and extinguishing equipment, pilot boarding equipment, and other equipment. Vessel fire pump piping inlet before the gate valve was found wasted and deteriorated. Submit temporary repair to the MI, and conduct approved temporary repairs until permanent repairs can be made at the vessels next drydock.
46 CFR 136.212 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Conducted in person def check. All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 August 2024
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Vessel was found with a cable penetration in the fwd bulk head of the engine that the composite material utilized is now deteriorated, effecting the ability of that penetration to be watertight. Repair and seal the penetration to the satisfaction of the MI.
46 CFR 140.605 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Vessel resealed bulkhead penetration, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 August 2024
Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a life jacket meeting requirements in 46 CFR 141.340, an immersion suit meeting requirements in 46 CFR 141.350, or a work vest approved by the Commandant under 46 CFR subpart 160.053. Vessel crew members were found wearing work vests that are not of the approved type. Replace work vest to the approved type or submit for special consideration.
46 CFR 140.430 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 7 November 2024
Resolution: Special Consideration was approved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2024
Resolved
Stowage positions for life jackets stowed in a berthing space or stateroom and all life jacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the life jackets stowed inside the container. Life jacket stowage did not contain markings with the minimum quantity stored. Add markings to the satisfaction of the MI.
46 CFR 141.340 (h)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Vessel was able to apply proper markings on Lifejacket stowage of crew accommodations.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 August 2024
Resolved
The Rules concerning shapes shall be complied with by day. Vessel did not have any day shapes on board. Procure and place day shapes applicable to the vessel on board or submit for special consideration.
33 CFR 83.20 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 10 January 2025
Resolution: Vessel provided dayshapes on board.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 August 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Pressure vessel relief valves need to be tested twice every 5 years, with no more than 3 years elapsing since last test. Port side relief was was tested and failed. Replace port side relief valve to the satisfaction of the marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Vessel replaced relief valve and was tasted satisfactory in the presence of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 August 2024
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency, including: (1) Responding to fires and flooding; (2) Responding to emergencies that necessitate abandoning the vessel; (3) Launching survival craft; (4) Taking action during heavy weather; (5) Taking action in the event of a person overboard; (6) Taking action relative to the tow; (7) Taking action in the event of failure of propulsion, steering, or control system; (8) Managing individuals onboard who are not crewmembers; (9) Managing any other event or condition which poses a threat to life, property, or the environment. Vessel was missing sections as outlined in the regulations on their duty station bill. Update the duty station bill covering all portions as outline to the satisfaction of the MI.
46 cfr 140.405 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Vessel updated station bill, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 August 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Alarm setpoints need to be tested twice every 5 years, with no more than 3 years elapsing since last test. Vessel was unable to provide testing records. Provide record of testing to the satisfaction of the MI.
46 CFR 143.245 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 27 September 2024
Resolution: Provided alarm setpoint testing records, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 August 2024
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. 06 signage markings were missing on the watertight doors. Signage was fixed in the presence of the marine inspector.
46 CFR 144.160 (e)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 August 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel filter site glass was found leaking. Repaired in the presence of the MI during inspection.
46 CFR 143.220
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 August 2024
Resolved
Annual inspections will be similar to the inspection for certification but will cover less detail unless the marine inspector finds deficiencies or determines that a major change has occurred since the last inspection. If the marine inspector finds deficiencies or finds that a major change to the vessel has occurred, he or she will conduct a more detailed inspection to ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. During annual inspection, hole in the bulkhead was identified behind the starboard air compressor. Repair prior to next credit drydock.
46 CFR 137.200 (b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 27 September 2024
Resolution: Vessel was able to properly weld the effected area in the superstructure bulkead. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 June 2024
Resolved
Closure devices must be provided for deckhouse or hull penetrations. Wooden doors on port and starboard side of bridge, and from berthing rooms are not weathertight. 46 CFR 144.320(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 31 July 2024
Resolution: Operator refurbished doors and installed weatherstripping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2024
Resolved
Each lifebuoy on a towing vessel must... Be marked in block capital letters with the name of the vessel. Ring buoy on forward main deck found without name of the vessel. 46 CFR 141.360(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 31 July 2024
Resolution: Operator marked lifering with vessel name.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2023
Resolved
Each operator or agent of a vessel with a capacity of 250 or more barrels of fuel oil...shall designate, either by name or by position in the crew, the person in charge (PIC) of each transfer to or from the vessel. Vessel must designate a PIC of fuel oil transfers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 28 June 2023
Resolution: Witnessed PIC list of employees
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2023
Resolved
Each towing vessel must have...a self-priming, power-driven, fixed fire pump, a fire main, and hoses. Fire main pump is leaking must repaired to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 28 June 2023
Resolution: Gasket replaced, and proper psi maintained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2023
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series..., for each person on board. Two lifejackets must be added IAW vessels COI. Vessel is permitted to carry 7 total persons at this time.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 July 2023
Resolution: Received satisfactory photograph of missing two lifejackets.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 22 June 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Damaged weathertight door in berthing space must be repaired to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 28 June 2023
Resolution: Door repaired satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2023
Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy. Port and starboard operating station lifebuoy water lights must have satisfactory lanyards added.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 9 July 2023
Resolution: Received satisfactory photographs of life buoys with acceptable floating light lanyards.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 22 June 2023
Resolved
Verify that bilges and other spaces are free of excessive accumulation of oil. Oil and debris must be cleaned and removed from engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 9 July 2023
Resolution: Received satisfactory photographs of cleaned bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Fuel filters are missing heat deflector bowls. Install bowls to satisfaction of MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 28 June 2023
Resolution: Heat shields installed properlly.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 21 July 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Watertight doors affixed to house and engine room failed to adequately secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 28 July 2022
Resolution: Watertight doors have been serviced and re-inspected by Marine inspector
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2022
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to every towing vessel of 7.8 meters (26 feet) or over in length, measured from end to end over the deck excluding sheer, while navigating. Vessel requires a bridge-to-bridge radio certificate on board and was unable to present such certificate.
47 CFR 80.1001(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 28 July 2022
Resolution: Recieved proof of bridge to bridge certificate
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 June 2021
Resolved
Each watertight door and hatch must be marked on both sides in clearly legible letters at least 1" high: "Watertight Door- Keep Closed". Vessel's two doors on the main deck leading from the accommodation space were not labeled on both sides.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 June 2021
Resolved 1 June 2021
Resolution: Deficiency corrected on the spot. Vessel added label to both sides of the doors.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 June 2021
Resolved
Means must be provided for stopping and closing each fan in a ventilation system servicing machinery spaces in case of fire. Vessel's two exhaust fans for the engine room do not have a ventilation closure installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 14 June 2021
Resolution: Operator installed ventilation closures for the engine room exhaust fans.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2021
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by bulkheads. Vessel's doorway leading to the machinery space from the main deck accommodation space has penetrations in the overhead that need to be sealed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 14 June 2021
Resolution: Operator sealed the penetrations in the bulkhead.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 1 June 2021
Resolved
Each Mattress must comply with either: (a) the Consumer product safety commission standard for mattress flammability (FF 4-72) or (b) IMO Resolution A.688(17). Vessel must have approved mattresses for it's 3 overnight accommodations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 3 June 2021
Resolution: Operator submitted documentation verifying that the new mattresses that he ordered mmet 16 CFR 1632, which meets part (a) of the regulation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018
Resolved
IMO: Vsl is broadcasting no IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 December 2020
Resolution: Verified vessel was no longer broadcasting AIS errors through NAVCEN's verification database.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010