Records from 2017 to 2026. Most recent: inspection, 8 July 2026.
Documentation record
Tonnage as PSIX records it115727 - Dead Weight, Metric Ton
134335 - Displacement, Metric Ton
35879 - Convention (Subpart B), Net Ton
35879 - Regulatory (Subpart C or D), Net Ton
61241 - Regulatory (Subpart C or D), Gross Ton
61241 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 17
8 July 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8433014
21 June 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8409263
3 December 2025
PSC B · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8276655
8 November 2025
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8267840
6 November 2025
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8264980
6 November 2025
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8265714
4 May 2025
PSC B · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8128021
3 May 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8128075
4 December 2024
COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8042424
8 March 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7877431
4 December 2023
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7833046
9 October 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7574148
16 October 2021
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7334023
28 December 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6591140
5 August 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6500941
3 August 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6499784
11 December 2017
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6320641
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO rcvd report that the vessel was unable to come up to the speed when requested by pilot while transiting in the COTP zone.
74SOLAS (20) 1/11(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2025
Resolution: Accepted class report from RINA and verified on board that the M/E is fully operational and the issue was communication on the pilot card.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 December 2017
Resolved
0750-fire fighting-For tankers 20,000 tonnes and upwards, the protection fo the cargo tanks shall be achieved by a fixed inert gas system in acordance with the requirements of the FSS CODE. Proper operation of vessel's IGS could not be verified by PSCO due to trouble shoting and repairs being made by technician at time of COC exam. IGS must be fully operational prior to dischargin cargoes having a flash point not exceeding 60 degrees Celsius. 74 SOLAS (2016)II-2/5.5.1.1 15AC
Action required: 15 - Rectify deficiencies by next port
Resolved 12 December 2017
Resolution: Received technician and class survey report stating that IGS has been repaired and is fully operational.