Records from 2011 to 2026. Most recent: inspection, 4 May 2026.
Documentation record
Registered dimensions (L × B × D)84.5 ft × 35.0 ft × 10.7 ft
Registered tonnagegross 287 / net 195
ITC dimensions (L × B × D)84.5 ft × 35.0 ft × 10.7 ft
ITC tonnagegross 368 / net 110
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGIBSON, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it110 - Convention (Subpart B), Net Ton
195 - Regulatory (Subpart C or D), Net Ton
368 - Convention (Subpart B), Gross Ton
287 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
4 May 2026
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8361583
24 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8287002
5 September 2025
TPO Audit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8227909
28 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8146162
4 December 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8043215
29 May 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7939053
28 May 2024
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7922748
8 August 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763507
13 April 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7668114
29 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7614170
29 November 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7647937
17 August 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7538226
17 August 2022
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7568602
10 November 2021
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7348933
7 July 2021
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7249999
12 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7124033
12 January 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7135696
3 June 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6967359
22 January 2020
Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6893864
10 April 2018
Administration · MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6388619
2 March 2014
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4810335
11 December 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4502434
23 September 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4448469
17 August 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4413596
5 October 2011
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4161791
5 October 2011
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4165531
28 July 2011
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4096813
28 July 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4120810
23 June 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4054555
23 May 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4021702
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 December 2025
Resolved
Vessel reported a loss of propulsion and loss of power, due to coolant leak on port generator. Vessel shall enact permanent repairs to the satisfaction of the TPO.
Ensure TPO report is submitted to MSU Texas City Domestic Inspections E-Mail: [email withheld]
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 December 2025
Resolved 24 December 2025
Resolution: It was found area of the gasket missing. Cleaning both surfaces made sure the housing was flat and revealed with new gasket,
Thermostats, and hose. Topped system off with coolant and ran. No other issues at this time.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 20 December 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components.
MI observed missing as well as burnt lagging on top of the port engine.
46 CFR 143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2025
Resolution: Received and accepted TPO report attesting to rectification of deficiency. See attached report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 December 2024
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised.
MI observed penetrations on both port and starboard bulkheads within the steering flat.
46 CFR 140.605(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2025
Resolution: Received and accepted TPO report attesting to rectification of deficiency. See attached report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be suitable for route and service. Vessel reported loss of STBD M/E. Vessel may proceed to Turn Services by assist tow for permanent repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2024
Resolution: Tech report provided. It was found that there was a lack of contact from the power cable to the terminal due to a broken lug. The damaged terminal lug was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2024
Resolved
Objective evidence attesting to root cause & satisfactory repair(s) IAW company TSMS must be submitted to local [name withheld] authorization of 835 clearance is required prior to being cleared to depart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2024