Records from 2002 to 2012. Most recent: inspection, 23 April 2012.
Inspection history · 15
23 April 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4293297
16 April 2012
Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4287720
14 January 2010
Administration
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3673421
31 January 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3403293
19 December 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3382657
19 December 2008
Administration
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3396522
10 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3294492
10 August 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3295184
10 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3296700
10 August 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3339415
6 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3291133
15 December 2006
MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2841198
29 October 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2232407
8 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2092239
19 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1721152
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 16 April 2012
No resolution recorded
Vessel is not fitted with LRIT system as required.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 16 April 2012
Resolved
Vessel is greater than 300 ITC and does not have a valid COFR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Vessel had valid certificates on board.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 April 2012
Resolved
Vessel is not in compliance with Minimum Safe Manning document. Missing one (1) Navigation Officer and Flag State endorsements for officers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Vessel''s on board crew meets Minimum Safe Manning Document
Stability › Watertight Integrity › General
Issued 16 April 2012
Resolved
Watertight doors do not close properly as designed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: All watertight doors are working as designed.
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2012
Resolved
Vessel is required to have current navigation publications. Vessel has outdated Coast Pilot and does not have any of the required publications.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: All required navigation publication are on board and up to date.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 16 April 2012
Resolved
Vessel does not have a spare bottle or a means to replenish the supplied SCBA for the fireman's outfit.
Due 30 April 2012
Resolved 26 April 2012
Resolution: Vessel has spare tank on board.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 April 2012
No resolution recorded
Crows nest radar is not an approved type. Currently a dome type. Radar needs to meet RTCM standards.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 April 2012
Resolved
Pilot House radar (#2 model # 1932) is not operating properly. A ring appears in the center of the screen leaving a blindspot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Tech repaired the #2 Radar for the vessel. Radar working properly now
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 April 2012
Resolved
Ladder to vessel's crows nest is broken/wasted presenting a hazard to the crew when accessing the crows nest.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Ladder to Crow Nest was repaired and welded back in place.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 April 2012
Resolved
Berthing areas are missing light covers.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Brething area lights covers have been installed.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 16 April 2012
Resolved
Vessel has expired documents as of 19MAR2012:
1. International Tonnage Certificate.
2. Certificate of class.
3. Safety Construction Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Vessel has valid Certs on board.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 16 April 2012
Resolved
Currently there is not enough food onboard to sustain crew to next port of call.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Vessel has enough food to last them to the next port of call
Electrical › Lighting (service) › Lighting Fixture
Issued 16 April 2012
Resolved
Emergency lighting throughout vessel is not operating properly.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Emergency lighting is working properly
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2012
Resolved
Vessel has excessive dead end wires. These wires are not known if live or dead. Remove dead end wires throughout vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Vessels dead end wires have been removed
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2012
Resolved
Port and starboard life rings are not in serviceable condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: New life rings are on board vessel
Engineering › Fuel Oil Service System › Vent Pipe
Issued 16 April 2012
Resolved
Vessel's fuel vent flamescreens need to be replaced.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: New flame screens have been installed.
Fire Fighting › Fire Hoses › Location
Issued 16 April 2012
Resolved
Firehoses are not mounted and readily accessible. Nozzle needs to be variable straight stream / fog.
Due 30 April 2012
Resolved 26 April 2012
Resolution: Fire hoses are mounted and secure. Nozzles have been replaced with correct ones.
Deck/Cargo › Towing › Main Drum
Issued 16 April 2012
Resolved
Gusset frames on the brake hub of the stern whinch are broken or missing. Repair or replace gussets to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Gusset frames have been repaired.
Deck/Cargo › Towing › Tackle
Issued 16 April 2012
Resolved
Third bullwork frame aft, port side has a broken stantion. Repair or replace to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Bullwork frame has been repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 April 2012
Resolved
Missing junction box cover for starboard exhaust fan.
Due 30 April 2012
Resolved 26 April 2012
Resolution: Junction box cover is installed.
Engineering › Fuel Oil Service System › Valve
Issued 16 April 2012
Resolved
Starboard #2 forward fuel tank has valve leaking fuel into the bilges. Repair/replace to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Fuel leak has been fixed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 April 2012
Resolved
OWS does not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: OWS was removed from the vessel
Engineering › Compressed Air System (control) › Valve
Issued 16 April 2012
Resolved
PRVs on air receivers painted over and not functioning as designed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: New PRV have been installed and working properly
Engineering › Steering Gear System › Piping
Issued 16 April 2012
Resolved
Steering pump has hydraulic leak, repair to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2012
Resolution: Hydraulic leak has been repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 April 2012
Resolved
Mount or remove light from port side engine room. Remove broken light fixture on aft bulkhead in engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Lights in the engine room have been fixed or removed.
Engineering › Fuel Oil Service System › Pump
Issued 16 April 2012
Resolved
Repair fuel leak on transfer pump gauge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Transfer pump gauge was removed.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 16 April 2012
Resolved
Gauges on MDE not functioning, repair/replace.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Gauges were removed
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 16 April 2012
Resolved
Missing covers on instrument panel for MDE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2012
Resolution: Light covers were installed