Records from 2011 to 2017. Most recent: inspection, 15 June 2017.
Inspection history · 7
15 June 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6174216
14 June 2016
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5906713
21 May 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5877996
22 June 2012
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4352369
22 June 2012
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4398246
15 August 2011
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4120047
8 July 2011
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4171179
Engineering › Steam Boiler (propulsion) › Piping
Issued 21 May 2016
Resolved
The Condition of the ship and its equipment shall be maintained to conform with the provisions of the regulations to ensure ship remains fit to proceed to sea without danger to the ship or persons on board. Multiple systems (general service pump, boiler, emergency fire pump) have leaks allowing for water ingress into the spaces. 74 SOLAS (14)I/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2016
Resolved 13 June 2016
Resolution: The attending surveyor confirmed that general service pump, boiler and emergency fire pump already repaired in oerder without leaking, and relevant spaces already cleaned and maintained with satisfaction. Funtion test of pumps carried out with satisfacti
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 June 2012
Resolved
ENTRIES IN THE OIL RECORD BOOK INDICATED 5 OVERBOARD DISCHARGES THROUGH A NON-FUNCTIONING OILY WATER SEPARATER. UPON INSPECTION OF THE INSIDE OF THE OVERBOARD DISCHARGE PIPE, THICK OILY RESIDUE WAS FOUND. MARPOL 73/78 (CONS 2006) ANNEX I REG 14.6
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2012
Resolved 7 July 2012
Resolution: New ORB established w/ effect on 30JUN12. All necessary entries were properly recorded and signed by the C/E and the Master... ORB was endorsed by NKK Surveyor.
Documentation › Logs/Records › Oil Record Book
Issued 22 June 2012
Resolved
ANY FAILURE OF THE OIL FILTERING EQUIPMENT SHALL BE RECORDED IN THE OIL RECORD BOOK PART 1. VESSEL DID NOT LOG THE FAILURE OF THE OILY WATER SEPARATOR PUMP INTO THE OIL RECORD BOOK.
MARPOL 73/78 (CONS 2006) ANNEX I REG 17.5
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2012
Resolved 7 July 2012
Resolution: New ORB established w/ effect on 30JUN12. All necessary entries were properly recorded and signed by the C/E and the Master... ORB was endorsed by NKK Surveyor.
Documentation › Logs/Records › Oil Record Book
Issued 22 June 2012
Resolved
EVERY SHIP OF 400 GROSS TONNAGE AND ABOVE SHALL BE PROVIDED WITH AN OIL RECORD BOOK PART ONE WHICH SHALL BE IN THE FORM SPECIFIED IN APPENDIX III TO ANNEX I. VESSEL FAILED TO PROPERLY CONDUCTED WEEKLY TANK SOUNDINGS ACCORDING TO PARAGRAPH (C ) OF THE ITEMS TO BE RECORDED IN THE OIL RECORD BOOK. MARPOL 73/78 (CONS 2006) ANNEX I REG 17.2.3
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2012
Resolved 7 July 2012
Resolution: New ORB established w/ effect on 30JUN12. All necessary entries were properly recorded and signed by the C/E and the Master... ORB was endorsed by NKK Surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 June 2012
Resolved
THE OILY WATER SEPARATOR PUMP MECHANICAL GEARING HAD BEEN ATTEMPTED TO BE TEMPORARILY REPAIR WITHOUT PROPER APPROVAL FROM CLASS FOLLOWING THE REPAIRS.
MARPOL 73/78 (CONS 2006) ANNEX I REG REG 6.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2012
Resolved 7 July 2012
Resolution: New parts were installed and proper operation of pump was witnessed by NKK Class Surveyor and USCG PSCO.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 June 2012
Resolved
FIRE PROTECTION SYSTEMS SHALL KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. STRUCTURAL FIRE PROTECTION, INCLUDING FIRE RESISTING DIVISION, PROTECTION OF OPENING AND PENETRATION SHALL BE MAINTAIN IN GOOD WORKING ORDER. NUMEROUS CLASS "A" FIRE DOORS DID NOT CLOSE SHUT. SOLAS 2004 (Cons. Ed.) Chapter II-2/14.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2012
Resolved 7 July 2012
Resolution: Witnessed proper operation on fire doors in attendance with NKK Class Surveyor.