Records from 2011 to 2025. Most recent: inspection, 17 June 2025.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSANTA MONICA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
17 June 2025
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093567
29 August 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7956145
7 September 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700929
26 July 2023
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700918
16 June 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466187
13 July 2021
Hull Examination · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241899
17 May 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7200390
16 May 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7221862
14 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7059397
13 October 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7076374
1 October 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6721358
26 August 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6721353
27 June 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6729068
27 September 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6538474
15 August 2017
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6200129
6 July 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6190109
13 August 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6013573
12 July 2016
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5923823
24 August 2015
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5225569
5 August 2015
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5207167
2 August 2011
DAPI Audit · Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4150477
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 August 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There is no visual indicator when bilge pump is operating (03 pumps). 46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Indicating lights operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Life Buoy retroreflective tape found to be worn out and in need of replacement. 46 CFR 185.604 (h)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: new retro tape applied
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 August 2024
Resolved
A vessel must carry either a Firs-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's First-aid kit missing a tourniquet and ammonia inhalants. 46 CFR 184.710.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: All items provided
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 June 2022
Resolved
On a vessel of at least 26ft in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space.
"belly compartment" high level visual indicator alarm did not function properly at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 17 June 2022
Resolution: Owner provided objective evidence for correcting deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2021
Resolved
Flexible hose designed for use with hose clamps installed may be installed with two clamps, at both ends of the hose, which may meet USCG A1, A2, B1, B2 in accordance with 33 CFR part 183 Subpart J. Vessel does not have approved hose installed. Vessel to provide approved hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 3 June 2021
Resolution: Vessel installed approved USCG A1 type felxible hose.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 October 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible. Forward fire extinguisher found to be in unmarked cabinet. Provide proper marking to make extinguisher clearly visible/identifiable. 46CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2020
Resolved 29 October 2020
Resolution: Vessel submitted photograph of satisfactory marking for fire extinguisher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel is overdue for its annual inspection. Vessel must complete a satisfactory annual inspection prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 14 October 2020
Resolution: The vessel satisfactorily completed their Annual Inspection. Act #7059397
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 October 2019
Resolved
Each vessel that operates on the high seas must have a float free Category 1 EPIRB. Hydrostatic release expired. Vessel restricted to less than three miles from shore until rectification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 14 October 2019
Resolution: MI verified proper installation of valid hydrostatic release.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 October 2019
Resolved
Vessel must have valid first aid kit. Majority of contents expired. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 14 October 2019
Resolution: MI verified presence of valid first aid kit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2018
Resolved
Missing 01 fire bucket.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 27 September 2018
Resolution: Bucket added
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 September 2018
Resolved
Nylock nut for winch upper furl had back off dur to nylock not being being engaged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 September 2018
Resolution: Nylock tightened.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 August 2017
Resolved
Through-bulkhead penetration in way of electrical not air/watertight. Seal properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 13 October 2017
Resolution: Vessel made proper repairs by sealing all through-bulkhead penetrations.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 August 2017
Resolved
Gasket on watertight hatch held on w/ tape. Permanently affix.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 13 October 2017
Resolution: Loose gasket material had been repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 6 July 2017
Resolved
replace lifering
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 15 August 2017
Resolution: New and marked lifering was installed on board at time of hull exam/ISE.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 July 2017
Resolved
renew COD
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 27 September 2018
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 10 September 2015
Resolved
Provide fire servicing report for fixed pre-engineered gas firefighting system (fireboy) to prove full agent weight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 25 September 2015
Resolution: Receieved new fire servicing report from the vessel's new servicing company, ROSS Fire Extinguisher, Inc., serviced 14SEP2015 - all satisfactory.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 September 2015
Resolved
Provide proof of FCC safety radiotelephony certificate & operator's permit.
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 25 September 2015
Resolution: Receieved proof of FCC radio safety certificate - all satisfactory.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 10 September 2015
Resolved
Provide proper port navigation light cover.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 25 September 2015
Resolution: Verified proper port navigation light cover - all satisfactory.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 10 September 2015
Resolved
Properly mark adult-size lifejacket space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 25 September 2015
Resolution: Verified proper adult lifejacket markings - all satisfactory.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 September 2015
Resolved
Service B:C I fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 25 September 2015
Resolution: Verified portable extinguisher was serviced, on 14SEP2015 by ROSS - all satisfactory.