MAURY USCG vessel records Sign in
← All vessels

LEGEND

LEGEND is a 1966 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1992, most recently in March 2026, along with 101 deficiencies, 9 operational controls and 3 casualty investigations between 2004 and 2019.

Records from 1992 to 2026. Most recent: inspection, 4 March 2026.

Built
1966
Last inspected
4 March 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8386
236497
Flag
UNITED STATES
368451760
Maury page id
psix-236497

Inspections, by type

…with no type recorded11
Years with a record 30 calendar years (1992–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 16.7 ft × 8.7 ft
Registered tonnagegross 63 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS CRAFT CORPORATION · POMPANO BEACH, FL, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 4 December 2024 · expires 30 November 2025
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ7319MMSI 368451760 · active · compulsorily equipped · granted 9 January 2026, expires 9 January 2036
WDC8386MMSI 367086230 · expired · compulsorily equipped · granted 11 February 2016, cancelled 14 March 2026
WCY9405MMSI not assigned · expired · compulsorily equipped · granted 17 March 1999, cancelled 23 May 2009
WBF3864MMSI not assigned · expired · compulsorily equipped · granted 2 May 1997, cancelled 16 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CLOUD 9 Passenger (Inspected) · MISLE 1126218 · 27 June 2019 · activity 6729068

Inspection history · 72

4 March 2026 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8129259
28 April 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8080988
3 April 2024 Appeal · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7871120
28 February 2024 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7837788
13 March 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624745
13 April 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7407248
16 February 2022 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7396876
9 February 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7134179
13 May 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6952505
13 February 2020 Hull Examination · In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874745
27 June 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6729068
23 April 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6620587
18 April 2018 In-Service Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392747
2 April 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384499
26 March 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6367643
16 January 2018 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340039
29 March 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6108125
29 February 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812279
9 February 2016 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812274
5 December 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4002253
29 November 2010 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3887466
24 March 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3696922
14 January 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3651380
1 December 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3643017
26 March 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3437401
6 December 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3108283
26 November 2007 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3104049
14 November 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3098743
11 January 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2564875
11 November 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2532944
25 October 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2518721
10 December 2004 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2258654
9 December 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2258687
28 September 2004 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2207250
25 September 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2207573
26 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2079959
14 January 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1980513
3 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1805433
19 June 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1635664
9 January 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1477678
22 May 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379449
15 August 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1052825
7 June 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384468
26 January 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423344
11 August 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427705
8 June 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388822
3 June 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368775
14 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1448997
28 July 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1116587
9 June 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421348
6 June 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359173
28 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435729
22 January 1996 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1190064
7 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886038
9 June 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 879140
2 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392122
21 November 1994 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 869779
9 November 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465799
20 September 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1180499
5 July 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370912
14 June 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439519
31 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356686
13 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169472
26 April 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1425442
2 August 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 848687
1 July 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153799
24 May 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 832704
19 May 1993 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841609
1 June 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1260941
29 May 1992 Initial Certification · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1262802
30 April 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1261170
1 April 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952227

Deficiency record · 101

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI discovered port main diesel engine oil filter actively leaking.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI discovered excessive oil accumulation in the engine room bilge and drip trays underneath the port and starboard main diesel engine breathers. Engine room is to be cleared of all oil accumulation prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2025 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed excessive oil accumulation outboard of the starboard engine. Clean area of oil and determine source. 46 CFR 182.01-5
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2025
Resolution: Vessel cleaned off oil, no noticeable oil leaks detected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 April 2025 Resolved
Except as otherwise provided in this section, all fixed fire extinguishing systems shall be of an approved carbon dioxide type and installed to the satisfaction of the Officer in Charge, Marine Inspection. MI observed the firefighting system eng. override switch not working. 46 CFR 181.20-5 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 7 May 2025
Resolution: Vessel master was able to demonstrate proper operation of the engine override switch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 April 2025 Resolved
he intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed oil soaked lagging on the starboard side engine's exhaust. Replace oil soaked lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 28 April 2025
Resolution: Oil on lagging insulation was superficial and was cleaned off.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 April 2024 Resolved
Vessel conducted a temporary repair to hull below the weather deck to facilitate watertight integrity of hull so passengers could be carried following inspection on 03APR2024 and cleared item #1. Repair was considered temporary and a permanent one shall be completed. Repair by either re-fastening port light to hull penetration or closing the hull penetration with the same wood material as hull shall include: verification of condition of port lights if chosen method, detailed process and list of materials that will be utilized to re-attached port light to hull or sealing/decommissioning hull penetration with wood. Once repair proposal is approved repairs can commence and will be verified by attending Marine Inspector. Guidance for wood repairs can be found in NVIC 7-95 or other recognized good marine practice publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 23 July 2024
Resolution: Port lights re-installed with new fasteners and adhesive.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 April 2024 Resolved
Each port light must be constructed so that it can be secured watertight. In the engine room port bulkhead there was port light without the proper closing devices and in the same bulkhead had another port light missing altogether compromising the hull’s watertight integrity.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2024
Resolution: Temporary repairs completed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 April 2024 Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Engine room dampers do not fit as designed. 705: 7 days
Action required: 705 - Other - as specified
Due 10 April 2024
Resolved 11 April 2024
Resolution: Received photo. Engine room dampers rectified to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
Separation of machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The bulkhead separating the E/R from the accommodation space has a hatch cover with a missing gasket affecting the vapor tight integrity of the space. Additionally, a trash compactor installed in the same bulkhead had light penetrating around the outer edge of the trash compactor, thus creating an open space for the passage of vapor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified no light penetration to prevent the passage of vapors.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 3 April 2024 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. Hatch cover to aft accommodation space contains no hardware to secure hatch or attach to deck to prevent overboard loss.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified the aft hatch secured to prevent overboard loss.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Outlet receptacles in engine room missing outlet covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified outlet covers on outlets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
All electrical installations shall be to the satisfaction of the OCMI. The alternator panel on the engine room aft bulkhead was not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified that alternator panel was properly secured in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
Flexible or portable cords such as SO, STO and similar types cannot be used for permanently installed wiring. Remove all portable extension cords currently in use throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified there were no extension cords in use throughout the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2024 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. The orange ring life buoy was not marked with the vessel’s name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Ring buoy labeled
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Electrical cable for A/C power located on overhead near starboard fuel tank not marine grade.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified electrical cable was marine grade.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2024 Resolved
The material used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1). MI unable to inspect Starboard fuel tank due to widespread scaling rust on top of tank. Remove scaling rust and make starboard fuel tank ready for re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: team verified that scaling was corrected on fuel tank.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
Nozzles, flanges, or other fittings for pipe connections shall be welded or brazed to the tank. The tank opening in way of pipe connections shall be properly reinforced where necessary. Where liquid level indicating gauges are installed, they shall be of heat resistant materials, adequately protected from mechanical damage and provided at the tank connections with devices which automatically close in the event of rupture of the gauge or gauge lines. Fuel level indication not of suitable material and valves to allow fuel to flow into sight glass require manual means of closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 10 May 2024
Resolution: Proper sight glass and valves that automatically close installed on Port fuel tank
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2024 Resolved
A vessel less than 100 gross tons operating on exposed or partially protected water permitted to have an opening port light below the weather deck shall have an inside, hinged dead cover. The port lights did not have inside, hinged dead covers. Submit plan for installing dead covers or any documentation that the vessel does not have to comply with the requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 15 May 2024
Resolution: O/O submitted invoices for Lexan material that was installed in the 30 portlights on the vessel. See Vessel Documents for invoices of Lexan from Company: Plexi Fab, Inc. located in Anaheim CA.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2024 Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: Bulwarks; Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Provide plan prior to installation to Marine Inspector for the installation of rail courses that meet the standard listed above.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 4 August 2024
Resolution: OCMI granted request for reconsideration.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI Observed excessive items being stored in the engine room creating unsafe fire load condition.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 April 2022
Resolved 13 April 2022
Resolution: O/O removed items being stored in engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a mannner as to avoid chafing and other damage.Electrical wiring within the engine space was found to be supported with plastic zip ties.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Electrical zip ties replaced with metal hangers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2021 Resolved
46CFR181.410(a)(3): Fixed gas fire extinguishing system design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. 46CFR181.410(d)(3): Piping, valves, and fittings must be securely supported, and where necessary, protected against damage. Piping for the fixed CO2 fire extinguishing system within the engine space was found to be supported with plastic zip ties.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: CO2 piping properly supported with metal hangers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. An electrical outlet located in vicinity of the interior steering console was found to have the hot and neurtral wires reversed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Electrical outlet corrected by a licensed electrician.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2020 Resolved
Each Inflatable liferaft required on a vessel by this part must have a capacity of 6 persons or more. Vessel is required to have a 50 man life raft. Prior to inspection vessels life raft failed inspection at avalon rafts. Owner purchased new raft and is waiting for it to arrive by mail. Owner provided invoice for new raft.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: Properly installed required life raft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2020 Resolved
All cables and wires must be protected by metal coverings or other suitable means. Junction box for a missing light has dead end wires hanging from it. Provide means to remove or cover dead end wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 27 May 2020
Resolution: Installed metel junction box covering.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2020 Resolved
A vessel must carry a first aid kit approved under 160.041 or equivalent. Vessels first aid kit had very few items and was not to 160.041 standards. Provide a first aid kit IAW 160.041 or equivalent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 27 May 2020
Resolution: Provided approved first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2019 Resolved
six life jackets found to have wasted retroreflective material. Replace retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019 Resolved
Vessel missing EPIRB Log. Provide an EPIRB Log with monthly EPIRB tests documented.
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2019 Resolved
Bildge in compartment aft of engine space contained excessive oil. Remove oil from bilge.
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 April 2018 Resolved
SUPERVISORY PERSONNEL NEED TO COMPLETE 60 MINUTES EAP TRAINING + ENSURE ALL CREWMEMBERS RECEIVE EAP TRAINING. 46CFR16.401(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 25 April 2018
Resolution: Received proof of Supervisory EAP Training and Crew EAP Training.
Communications › Radio Communications › EPIRB
Issued 26 March 2018 Resolved
Provide proof of replacing EPIRB battery. Vessel route limited to 3 NM from baseline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 27 March 2018
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 26 March 2018 Resolved
Remove excessive oil from engine room bilge.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 2 April 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 March 2018 Resolved
Replace stern light bulb prior to night or low visibility operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 2 April 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 29 March 2017 Resolved
Did not have Class "D" DSC Radio installed onboard. Provide and install Class "D" DSC Radio to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 6 April 2017
Resolution: Installed Class "D" DSC Radio; All Satisfactory.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 March 2017 Resolved
Owners could not provide proof of valid FCC Radio Operator's Permit. Provide proof of valid FCC Radio Operator's Permit to the satisfaction of the attending marine inspector. 47CFR80
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 25 April 2017
Resolution: Vessel representative provided proof of valid FCC radio operator's permit; all satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 16 February 2016 Resolved
Closure devices for supply duct openings to engine rooms missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Provided closure devices for the supply duct openings to engine rooms.
Communications › Radio Communications › EPIRB
Issued 9 February 2016 Resolved
Hydrostatic release on EPIRB was not serviced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Owner purchasd new hydrostatic release.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 December 2010 Resolved
Provide working waterlight IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Performed function test.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 December 2010 Resolved
Provide safety lanyard for rescuer.
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Provided lanyard.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 17 December 2010 Resolved
Crankcase breather lines are lead to canister that collects oil and is overflowing into the bilges. Remove excess oil and drain canisters prior to getting underway.
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Removed and cleaned
Engineering › Fuel Oil Service System › Piping
Issued 17 December 2010 Resolved
Provide clamps for flexible fuel hose lines in way of generator IAW 46 CFR 182.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Fuel clamps added.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 December 2010 Resolved
Provide suitable piping for raw water cooling sys. in way of generator. IAW 46 CFR 182.720.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Hose with manufacturer fittings installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 December 2010 Resolved
Provide shielding for hazardous rotating machinery for starboard main engine in way of engine room IAW 46 CFR 177.960
Action required: 705 - Other - as specified
Due 15 January 2011
Resolved 29 December 2010
Resolution: Clear plexi-glass added
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2010 Resolved
Renew as original lifeline, in way of ring lifebuoy IAW 46 CFR 180.70(c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2010
Resolved 17 December 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 November 2010 Resolved
Provide 3' lanyard for waterlight on Ring lifebuoy IAW 46 CFR 180.70(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2010
Resolved 29 December 2010
Resolution: Lanyard and corrosion resistant clip provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 November 2010 Resolved
Replace degraded retroreflective tape for 19 Lifejackets discussed during inspection, IAW 46 CFR 185.604 Vessel restricted to carrying no more than 30 Passengers until complete.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Communications › Radio Communications › EPIRB
Issued 29 November 2010 Resolved
Provide new disposable Hydrostatic Release unit IAW 46 CFR 185.740. Vessel restricted to no more than 3 miles from coastline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2010 Resolved
Prove proper operation of all around white light (anchor light). Vessel restricted to daylight operations until complete.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 November 2010 Resolved
Provide tide and current tables.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 29 December 2010
Resolution: Provided tide and current tables.
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 November 2010 Resolved
Provide Coast Pilot.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Resolution: Provided Coast Pilot
Communications › Radio Communications › EPIRB
Issued 29 November 2010 Resolved
Provide updated EPIRB registration with the correct call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 29 December 2010
Resolution: Registration reflected correct call sign
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 29 November 2010 Resolved
Provide name and hailing port in way of transom, IAW 46 CFR 185.602
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 31 January 2011
Resolution: Name and hailing port have been provided on the transom.
Documentation › Logs/Records › Drug Test Records
Issued 29 November 2010 Resolved
Provide proof of pre-employment drug testing and results, for crewmembers operating in a safety sensitive function. IAW 46 CFR 16.210
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Resolution: Completed satisfactory DAPI Audit
Documentation › Logs/Records › Drug Test Records
Issued 29 November 2010 Resolved
Provide documentation for background checks for crewmembers enrolled in a random drug testing program under a different marine employer. IAW 49 CFR 40.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Resolution: Completed satisfactory DAPI Audit
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 November 2010 Resolved
Provide proof crewmembers are properly trained before assuming safety sensitive position. IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Resolution: Completed satisfactory DAPI Audit
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 November 2010 Resolved
Provide proof supervisor has received one (1) hour EAP training. IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 17 December 2010
Resolution: Completed satisfactory DAPI Audit
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 March 2010 Resolved
Light attach to life ring did not function. Need to replace bulb or battery.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Witnessed light working
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 March 2010 Resolved
Hydrostatic release for the life raft has expired. Must replace.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Saw new hydrostatic release.
Lifesaving › Inflatable Liferafts › Servicing
Issued 24 March 2010 Resolved
Servicing date for life raft expires in less than a week. Need to show proof of servicing.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Witnessed servicing paper work.
Lifesaving › Hand Flares › Quantity
Issued 24 March 2010 Resolved
Vessel does not have the proper number of flares on board.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Has all reqiured flares on board
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2010 Resolved
Need to get corrected charts of operating area along with all publications required. (US Coast Pilot, CG Light List, Tide and Tables)
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Went through all pubs and charts. All satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 March 2010 Resolved
Engine room fixed fire fighting system inspection date expires in 7 days. Show proof of fixed FF system being serviced.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Inspected servicing record. All satisfactory
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 24 March 2010 Resolved
Bilge pump inoperative. Prove proper operation of bilge pump and all dewatering valves.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Witnessed bilge pump work and all valves operate.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 March 2010 Resolved
No alcohol test strips on board.
Action required: 705 - Other - as specified
Due 24 May 2010
Resolved 12 May 2010
Resolution: Inspected new test strips
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2009 Resolved
Provide proof of annual servicing to fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2009
Resolution: Vessel''s CO2 system was serviced on 27 March faxed service report.
Electrical › Electric Supply System (service) › Cable
Issued 26 March 2009 Resolved
Remove dead end wire in bulkhead in main passenger parlor.
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 14 January 2010
Resolution: Dead end wire verified removed.
Lifesaving › Inflatable Liferafts › Servicing
Issued 6 December 2007 Resolved
Provide proof of annual service for inflatable liferaft, route is restricted to no more than 3 miles from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 13 December 2007
Resolution: Recived annual service certifcate #167651 dated 12/11/2007 as prrof of annual service.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 November 2007 Resolved
1. YOU MUST UNDERGO A SATISFACTORY HULL INSPECTION PRIOR TO CARRYING PASSENGERS FOR HIRE AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 14DEC07.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2007
Resolved 6 December 2007
Resolution: Completed Satisfactory hull exam.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 November 2007 Resolved
VSL MUST UNDERGO A SATISFACTORY ANNUAL EXAM PRIOR TO CARRYING PASSENGERS FOR HIRE AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NLT 29DEC07.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2007
Resolved 6 December 2007
Resolution: Annual exam completed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 November 2005 Resolved
Vessel's last annual inspection was conducted on 26 May 04. Vessel is restricted from carrying passenger until a satisfactory examination is conducted.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2005
Resolved 26 December 2005
Resolution: Completed COI.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 25 October 2005 Resolved
Develop provision to close all supply & exhaust openings to space protected by fixed gas extinguishing system. 46 C.F.R. 182.465(h)
Due 25 November 2005
Resolved 25 November 2005
Resolution: Received phone call from [name withheld] atesting that now the vessel has means to secure vent openings to engine room.
Engineering › Reduction Gearing/Clutches › Gear
Issued 10 December 2004 Resolved
Clutching system locked up on starboard engine and could not be disengaged. Repairs need to be made prior to sailing.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 March 2005
Resolution: Cleared
Construction/Loadline › Hull › Side Shell
Issued 10 December 2004 Resolved
The wooden hull was breached just forward of the collision bulkhead on the starboard side after alliding with two sail boats. Repairs are needed prior to sailing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 March 2005
Resolution: Repaired
Lifesaving › Inflatable Liferafts › Servicing
Issued 10 December 2004 Resolved
Provide approved service to liferaft. Route restricted to LBS until cleared.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2005
Resolved 18 March 2005
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 September 2004 Resolved
Repair all fire damaged circuits IAW approved repair proposal and IAW 46 CFR Part 183 prior to carrying passengers and to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Due 28 September 2004
Resolved 18 March 2005
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 28 September 2004 Resolved
Repair/demonstrate to the satisfaction of the Marine Inspector; the proper operation, maneuverability, and shut-down of both main engines prior to carrying passengers.
Condition: Improper Installation
Due 28 September 2004
Resolved 18 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 September 2004 Resolved
Remove all unapproved household/temporary wiring that is used for permanently mounted equipment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2004
Resolved 18 March 2005
Electrical
Issued 22 May 2001 Resolved
Install metallic wire supports IAW 46 CFR 183.340(b)(4).
Condition: Unknown
Due 21 June 2001
Resolved 9 January 2002
Resolution: Deficiency cleared, metallic wire supports installed. All satisfactory.
Lifesaving
Issued 22 May 2001 Resolved
Replace EPIRB hydrostatic release & ensure expiration dates are shown. To be completed prior to carrying passengers for hire.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Documentation
Issued 22 May 2001 Resolved
Provide copy of latest MIS form IAW 46 CFR 16.500.
Condition: Unknown
Due 21 June 2001
Resolved 7 June 2001
Lifesaving
Issued 7 June 2000 Resolved
Replace broken lifefloat paddle.
Condition: Unknown
Due 21 June 2000
Resolved 27 June 2000
Navigation
Issued 7 June 2000 Resolved
Ensure port side steering gear packing is tightened.
Condition: Unknown
Due 21 June 2000
Resolved 27 June 2000
Construction/Loadline
Issued 8 June 1999 Resolved
Replace all PVC bilge piping in engine room with ferrous material in compliance with 46 cfr 182.710 to the satisfaction of marine inspectore.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Construction/Loadline
Issued 8 June 1999 Resolved
Place metallic fittings on all plastice penetrations of watertight bulkheadin compliance with 46 CFR 182.720.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Lifesaving
Issued 8 June 1999 Resolved
Post Emegency Broadcast instruction near radio.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Construction/Loadline
Issued 22 January 1996 Resolved
Make vessel available for hull inspection by a qualified marine inspector.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Navigation
Issued 9 June 1995 Resolved
Provide Notice to Mariners updates to Light List.
Condition: Unknown
Due 23 June 1995
Resolved 22 June 1995
Lifesaving
Issued 9 June 1995 Resolved
Relable children's PFD locker.
Condition: Unknown
Due 23 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 5 July 1994 Resolved
CLEAN AND TREAT DRYROT IN WAY OF THE PORT ENGINEROOM NATURAL VENTILATION AND IN THE BILGE OF THE AFT COMPARTMENT.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 14 June 1994 Resolved
MAKE PORT AND STARBOARD ENGINEROOM ELECTRIC SUPPLY VENTILATION OPENINGS _x001C_ WATERTIGHT. REROUTE OPENING WELL ABOVE THE WEATHER DECK. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Construction/Loadline
Issued 31 May 1994 Resolved
MAKE PORT & STARBOARD HULL SIDE OPENINGS BELOW THE WEATHER DECK WATERTIGHT.(ENGINEROOM NATURAL VENTS).PROVIDE ADEQUATE VENTILATION FOR THE ENGINEROOM.VENTILATION OPENING TO BE ABOVE THE WEATHER DECK. _x001C_ _x001C_
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Engineering
Issued 24 May 1993 Resolved
RENEW STARBOARD FUEL TANK VENT SCREEN.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Lifesaving
Issued 24 May 1993 Resolved
PROPERLY SECURE THE LIFEFLOAT FLOAT-FREE LINK TO THE DECK.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Lifesaving
Issued 24 May 1993 Resolved
PROPERLY STORE THE NINE (9) ADDITIONAL PASSENGER LIFEJACKETS TO MAKE ACCESSIBLE FOR PASSENGERS AND LABEL STORAGE FOR SAME.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 24 May 1993 Resolved
PROVIDE EMERGENCY LIGHTING FOR ALL BELOW DECK PASSENGER SPACES. VESSEL IS RESTICTED TO THE CARRIAGE OF PASSENGERS ABOVE DECK DURING AFTER HOURS UNTILCOMPLIANCE WITH THIS REQUIREMENT.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Lifesaving
Issued 24 May 1993 Resolved
PROVIDE ONE (1) ADDITIONAL CG APPROVED TYPE 1 ADULT LIFEJACKET PRIOR TO CARRYING MORE THAN 54 ADULT PASSENGERS.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Documentation
Issued 24 May 1993 Resolved
PROVIDE PROOF OF CHEMICAL TESTING FOR REQUIREMENTS IN 46 CFR 16, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Lifesaving
Issued 29 May 1992 Resolved
PROVIDE ONE (1) WATERLIGHT AND 4-FT PADDLES FOR EACH LIFE FLOAT. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Lifesaving
Issued 29 May 1992 Resolved
PROVIDE ONE (1) ADDITIONAL 6-MAN COAST GUARD APPROVED LIFE FLOAT. VESSEL _x001C_IS LIMITED TO 40 PERSONS ON BOARD UNTIL REQUIREMENT IS COMPLETED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Fire Fighting
Issued 29 May 1992 Resolved
PROVIDE CERTIFICATION THAT A SIPHON TUBE IS INSTALLED AS PART OF THE 75 _x001C_ LB CO2 BOTTLE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Fire Fighting
Issued 29 May 1992 Resolved
PROVIDE A MEANS TO SECURE THE NATURAL VENTILATION IN THE ENGINE ROOM UPON _x001C_ACTIVATION OF THE FIXED CO2 SYSTEM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992

Casualty record · 3

25 September 2004Routine · role: Involved in a Marine Casualty · activity 2207573
9 December 2004Routine · role: Involved in a Marine Casualty · activity 2258687
27 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6729068
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.