Records from 2004 to 2026. Most recent: inspection, 4 March 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI discovered port main diesel engine oil filter actively leaking.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI discovered excessive oil accumulation in the engine room bilge and drip trays underneath the port and starboard main diesel engine breathers. Engine room is to be cleared of all oil accumulation prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2026
Resolved 10 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2025
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed excessive oil accumulation outboard of the starboard engine. Clean area of oil and determine source. 46 CFR 182.01-5
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2025
Resolution: Vessel cleaned off oil, no noticeable oil leaks detected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 April 2025
Resolved
Except as otherwise provided in this section, all fixed fire extinguishing systems shall be of an approved carbon dioxide type and installed to the satisfaction of the Officer in Charge, Marine Inspection. MI observed the firefighting system eng. override switch not working. 46 CFR 181.20-5 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 7 May 2025
Resolution: Vessel master was able to demonstrate proper operation of the engine override switch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 April 2025
Resolved
he intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI observed oil soaked lagging on the starboard side engine's exhaust. Replace oil soaked lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 28 April 2025
Resolution: Oil on lagging insulation was superficial and was cleaned off.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 April 2024
Resolved
Vessel conducted a temporary repair to hull below the weather deck to facilitate watertight integrity of hull so passengers could be carried following inspection on 03APR2024 and cleared item #1. Repair was considered temporary and a permanent one shall be completed. Repair by either re-fastening port light to hull penetration or closing the hull penetration with the same wood material as hull shall include: verification of condition of port lights if chosen method, detailed process and list of materials that will be utilized to re-attached port light to hull or sealing/decommissioning hull penetration with wood. Once repair proposal is approved repairs can commence and will be verified by attending Marine Inspector. Guidance for wood repairs can be found in NVIC 7-95 or other recognized good marine practice publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 23 July 2024
Resolution: Port lights re-installed with new fasteners and adhesive.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 April 2024
Resolved
Each port light must be constructed so that it can be secured watertight. In the engine room port bulkhead there was port light without the proper closing devices and in the same bulkhead had another port light missing altogether compromising the hull’s watertight integrity.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2024
Resolution: Temporary repairs completed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 April 2024
Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Engine room dampers do not fit as designed.
705: 7 days
Action required: 705 - Other - as specified
Due 10 April 2024
Resolved 11 April 2024
Resolution: Received photo. Engine room dampers rectified to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024
Resolved
Separation of machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The bulkhead separating the E/R from the accommodation space has a hatch cover with a missing gasket affecting the vapor tight integrity of the space. Additionally, a trash compactor installed in the same bulkhead had light penetrating around the outer edge of the trash compactor, thus creating an open space for the passage of vapor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified no light penetration to prevent the passage of vapors.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 3 April 2024
Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. Hatch cover to aft accommodation space contains no hardware to secure hatch or attach to deck to prevent overboard loss.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified the aft hatch secured to prevent overboard loss.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Outlet receptacles in engine room missing outlet covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified outlet covers on outlets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
All electrical installations shall be to the satisfaction of the OCMI. The alternator panel on the engine room aft bulkhead was not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified that alternator panel was properly secured in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
Flexible or portable cords such as SO, STO and similar types cannot be used for permanently installed wiring. Remove all portable extension cords currently in use throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified there were no extension cords in use throughout the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2024
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. The orange ring life buoy was not marked with the vessel’s name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Ring buoy labeled
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Electrical cable for A/C power located on overhead near starboard fuel tank not marine grade.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Team verified electrical cable was marine grade.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2024
Resolved
The material used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1). MI unable to inspect Starboard fuel tank due to widespread scaling rust on top of tank. Remove scaling rust and make starboard fuel tank ready for re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 22 April 2024
Resolution: team verified that scaling was corrected on fuel tank.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024
Resolved
Nozzles, flanges, or other fittings for pipe connections
shall be welded or brazed to the tank. The tank opening in way of pipe connections shall be properly reinforced where necessary. Where liquid level indicating gauges are installed, they shall be of heat resistant materials, adequately protected from mechanical damage and provided at the tank connections with devices which automatically close in the event of rupture of the gauge or gauge lines. Fuel level indication not of suitable material and valves to allow fuel to flow into sight glass require manual means of closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 10 May 2024
Resolution: Proper sight glass and valves that automatically close installed on Port fuel tank
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2024
Resolved
A vessel less than 100 gross tons operating on exposed or partially protected water permitted to have an opening port light below the weather deck shall have an inside, hinged dead cover. The port lights did not have inside, hinged dead covers. Submit plan for installing dead covers or any documentation that the vessel does not have to comply with the requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 15 May 2024
Resolution: O/O submitted invoices for Lexan material that was installed in the 30 portlights on the vessel. See Vessel Documents for invoices of Lexan from Company: Plexi Fab, Inc. located in Anaheim CA.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2024
Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: Bulwarks; Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Provide plan prior to installation to Marine Inspector for the installation of rail courses that meet the standard listed above.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 4 August 2024
Resolution: OCMI granted request for reconsideration.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI Observed excessive items being stored in the engine room creating unsafe fire load condition.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 April 2022
Resolved 13 April 2022
Resolution: O/O removed items being stored in engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a mannner as to avoid chafing and other damage.Electrical wiring within the engine space was found to be supported with plastic zip ties.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Electrical zip ties replaced with metal hangers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2021
Resolved
46CFR181.410(a)(3): Fixed gas fire extinguishing system design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. 46CFR181.410(d)(3): Piping, valves, and fittings must be securely supported, and where necessary, protected against damage. Piping for the fixed CO2 fire extinguishing system within the engine space was found to be supported with plastic zip ties.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: CO2 piping properly supported with metal hangers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. An electrical outlet located in vicinity of the interior steering console was found to have the hot and neurtral wires reversed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Electrical outlet corrected by a licensed electrician.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2020
Resolved
Each Inflatable liferaft required on a vessel by this part must have a capacity of 6 persons or more. Vessel is required to have a 50 man life raft. Prior to inspection vessels life raft failed inspection at avalon rafts. Owner purchased new raft and is waiting for it to arrive by mail. Owner provided invoice for new raft.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: Properly installed required life raft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2020
Resolved
All cables and wires must be protected by metal coverings or other suitable means. Junction box for a missing light has dead end wires hanging from it. Provide means to remove or cover dead end wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 27 May 2020
Resolution: Installed metel junction box covering.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2020
Resolved
A vessel must carry a first aid kit approved under 160.041 or equivalent. Vessels first aid kit had very few items and was not to 160.041 standards. Provide a first aid kit IAW 160.041 or equivalent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 27 May 2020
Resolution: Provided approved first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2019
Resolved
six life jackets found to have wasted retroreflective material. Replace retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019
Resolved
Vessel missing EPIRB Log. Provide an EPIRB Log with monthly EPIRB tests documented.
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2019
Resolved
Bildge in compartment aft of engine space contained excessive oil. Remove oil from bilge.
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 April 2018
Resolved
SUPERVISORY PERSONNEL NEED TO COMPLETE 60 MINUTES EAP TRAINING + ENSURE ALL CREWMEMBERS RECEIVE EAP TRAINING. 46CFR16.401(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 25 April 2018
Resolution: Received proof of Supervisory EAP Training and Crew EAP Training.
Communications › Radio Communications › EPIRB
Issued 26 March 2018
Resolved
Provide proof of replacing EPIRB battery. Vessel route limited to 3 NM from baseline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 27 March 2018
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 26 March 2018
Resolved
Remove excessive oil from engine room bilge.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 2 April 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 March 2018
Resolved
Replace stern light bulb prior to night or low visibility operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 2 April 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 29 March 2017
Resolved
Did not have Class "D" DSC Radio installed onboard. Provide and install Class "D" DSC Radio to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 6 April 2017
Resolution: Installed Class "D" DSC Radio; All Satisfactory.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 March 2017
Resolved
Owners could not provide proof of valid FCC Radio Operator's Permit. Provide proof of valid FCC Radio Operator's Permit to the satisfaction of the attending marine inspector. 47CFR80
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 25 April 2017
Resolution: Vessel representative provided proof of valid FCC radio operator's permit; all satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 16 February 2016
Resolved
Closure devices for supply duct openings to engine rooms missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Provided closure devices for the supply duct openings to engine rooms.
Communications › Radio Communications › EPIRB
Issued 9 February 2016
Resolved
Hydrostatic release on EPIRB was not serviced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Owner purchasd new hydrostatic release.