Records from 2016 to 2026. Most recent: inspection, 22 May 2026.
Inspection history · 29
22 May 2026
COE-Administrative
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8378487
25 February 2026
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8316881
31 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8304481
17 December 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8278688
1 October 2025
COE-Administrative
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8244248
4 June 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8148373
18 May 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8138672
18 May 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8139694
10 November 2024
Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8032452
16 April 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7663026
5 April 2023
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7662980
27 January 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7624631
13 July 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500598
7 February 2022
Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7388903
23 December 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7372161
22 August 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7293300
20 August 2021
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7285596
27 December 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6873692
28 November 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6583238
2 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6296613
30 May 2017
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6159911
22 April 2017
PI Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6130675
22 April 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6137229
2 March 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6097645
11 October 2016
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6018817
26 September 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6009359
18 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5799062
17 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5799916
7 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5793364
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 April 2023
Resolved
PSCO notified by attending river pilot that the main engine was unable to start. PSCO attended vessel to corroborate pilot's report and confirmed with crew that main engine is unable to start. Cause of failure is undetermined.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2023
Resolution: Received Class report attesting to repair of M/E main air starting valve and subsequent successful operation of the M/E.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 27 January 2023
Resolved
A record shall be kept, to the satisfaction of the administration and as required by the Radio Regulations of all incidents connected with the radiocommunuication service which appear to be of importance to safety of life at sea. GMDSS logbook did not have two weekly tests recorded.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 January 2023
Resolved 27 January 2023
Resolution: Tested all weekly equipment for GMDSS and ensured crew was familiar with requirements to log tests.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 February 2022
Resolved
The Coast Guard will not allow the discharge of ballast if the vessel is required to have a USCG approved ballast water treatment system. PSCO observed non-approved ballast water operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2022
Resolution: Sec.Charleston received photos of proper chemical treatment requried for ballast water operations on board the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 7 February 2022
Resolved
The angular position of the rudder shall be indicated on the navigation bridge. PSCO observed rudder off in steering gear room by 05 degrees.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Sec. Charleston received class report, vessel will contact installation company to have def. corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to remain fi to proceed to sea without danger to ship or persons on board. PSCO observed excessive oil in purifier room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 July 2022
Resolution: PSCO went onboard to verify fix and saw class documentation.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 7 February 2022
Resolved
Fire control plans shall be kept up to date. PSCO observed fire fighting appliances not in accordance with fire control plan.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 July 2022
Resolution: PSCO went onboard to verify fix and saw class documentation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 February 2022
Resolved
The position of the load line of the ship shall correspond to the certificate. Load line does not match certificate.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 July 2022
Resolution: PSCO went onboard to verify fix and saw class documentation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 February 2022
Resolved
Fire protection systems shall be maintained and ready for use. PSCO observed water mist system in local control.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2022
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 February 2022
Resolved
Fire protection systems shall be maintained and ready for use. PSCO observed CO2 head forward port main engine taped over
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 7 February 2022
Resolved
Safety management system shall be maintained. PSCO observed alterations to deck piping on port side not reported to company as per SMS.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 February 2022
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance. PSCO observed hold backs on 03 class A doors.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed maintenance pins inserted in all CO2 bottles, rendering them inoperational. Vessel departed drydock on 22JUL21. - 74 SOLAS (20) II-2/14.2.1.2 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2021
Resolved 20 August 2021
Resolution: Crew removed maintenance pins from the CO2 bottles, restoring the system to an operational status.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 August 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed a soft patch on the A/C piping below the waterline. - 74SOLAS (20) I/11.a - 15ac
Action required: 15 - Rectify deficiencies by next port
Due 20 August 2021
Resolved 24 August 2021
Resolution: Received class report, cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 August 2021
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. PSCO observed crew utilizing inappropriate equipment to test flame detetors. UV lamp required to test as per manufacturer. - 74 SOLAS (20) II-2/14.2.2.1 - 15ac
Action required: 15 - Rectify deficiencies by next port
Due 20 August 2021
Resolved 29 August 2021
Resolution: Flame detector lamp was ordered and delivered to the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 23 April 2017
Resolved
The machinery and fittings shall be of a design and construction for the service for which they are intended. The expansion rubber joint on the raw water intake failed, causing the ME to over heat. Additionally causing the gasket between the cylinder head and liner to fail, allowing water into the #8 cylinder. SOLAS 14 Ch. II-I Reg. 26.1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 24 April 2017
Resolution: Received Class report attesting to the proper repairs.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 April 2017
Resolved
The VRP must have the Geographic-specific appendix for each COTP Zone in which the vessel operates. The VRP does not have the correct information, for any Ports listed on the East Coast. 33 CFR 155.5030 (c) 9 40c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 April 2017
Resolved 30 May 2017
Resolution: vessel submitted updated information for VRP.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 11 October 2016
Resolved
0725-Fixed fire extinguishing installation-Fire fighting systems shall be kept in good working order and readily available for immediate use. PSCO observed the manual system supply valve prior to the soleniod manifold on the vsl's hypermist system closed rendering the system unable to operate automatically. Attached sign on valve stated:"KEEP THIS VALVE OPEN ALWAYS".SOLAS74(2014cons)II-2/14.2.1.2
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 12 October 2016
Resolution: Vessel has been release from SOLAS Detention. Recieved class report and documentation that training was given to the crew on operation of the hyper-mist system and new SMS procedures were implemented by the company & vsl.