Records from 2012 to 2024. Most recent: inspection, 5 November 2024.
Inspection history · 28
5 November 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8029064
16 May 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7913914
6 May 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7907345
20 April 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7667048
30 August 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7546868
24 March 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7417694
14 October 2021
PSC B · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7329514
22 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7293498
20 February 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7143332
19 February 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7143199
19 February 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7155020
18 September 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7060651
20 April 2019
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6666534
8 September 2017
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6262456
23 July 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6219030
11 July 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6196892
5 July 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6198157
30 April 2017
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6136426
7 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6101300
26 February 2017
Administrative Inspection · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091440
17 October 2016
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6023800
9 September 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5996230
15 April 2016
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5854749
13 April 2016
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5853421
30 December 2015
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5787746
18 October 2015
COE-Dockside
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5745090
25 August 2015
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5225867
19 June 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4345031
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 5 November 2024
No resolution recorded
The master, owner, operator, agent, or PIC, of any vessel equipped with ballast water tanks that operates in the waters of the United States, must remove fouling organisms from the vessel's hull on a regular basis, and dispose of any removed substances in accordance with local, state, and federal regulations. PSCO observed excessive growth of fouling organisms on the STBD side of the vessel's hull. Provide Class documents or the certificate issuing authority attesting the removal of fouling organisms.
33 CFR 151.2050 (f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 14 October 2021
Resolved
Each operation described in paragraph 2 of this regulation shall be recorded without delay in the oil record book part I, so that all entries in the book are completed. Prior crew made numerous mistakes in oil record book. Mistakes were the throughput of the oily water seperator which was exceeded placing too much bilge water in the tank and capacity of the tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 31 December 2021
Resolution: Received RO report
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 14 October 2021
Resolved
Oil filtering Equipment shall have regard to the specification recommended by the organization. Ship staff training should include familiarization in the operation an maintenance of the equipment. Chief Engineer was unfamiliar with procedures for showing history of oily water seperator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 31 December 2021
Resolution: Recieved RO Report
Documentation › Certificates/Documents › IOPP Certificate
Issued 9 September 2016
Resolved
The International Oil Pollution Prevention Certificate shall be drawn up in the form corresponding to the model given. Form A supplement to the International Oil Pollution Prevention Certificate 2.4 is missing the maximum throughput of the system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 12 September 2016
Resolution: Received Class Survey verifying deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 September 2016
Resolved
Oil filtering equipment shall be of design such as will ensure that any oil discharged into the sea after passing an oil content not exceeding 15ppm. Observed SIM card required to record the log on the oil content meter selected to off.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 9 September 2016
Resolution: Observed oil content meter's SIM card selected to ON.
Construction/Loadline › Markings › Load Line Mark
Issued 25 August 2015
Resolved
The ring, lines and letters shall be printed in white or yellow on a dark ground. Vessels load line markings are not plainly visible. ICLL (88 Prot.) Reg. 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2015
Resolved 30 December 2015
Resolution: Vessel loadline marks have been renewed to be in compliance with ILLC (prot) reg 8.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 25 August 2015
Resolved
Emergency generating set shall be capable of being readily started. The second source of energy, which are batteries, were unable to start the emergency generator due to low voltage. '74(2004 Cons.) Ch. II-1/Reg. 44.1.
Action required: 705 - Other - as specified
Resolved 26 August 2015
Resolution: Vessel master contacted vessel agent who brought on board a new set of batteries. The E-Gen was satisfactorily tested using first and second means of starting.