Records from 2012 to 2026. Most recent: inspection, 18 August 2026.
Documentation record
Registered dimensions (L × B × D)287.0 ft × 60.0 ft × 26.5 ft
Registered tonnagegross 2,897 / net 2,897
ITC dimensions (L × B × D)287.0 ft × 60.0 ft × 26.5 ft
ITC tonnagegross 3,435 / net 2,035
BuilderSENESCO MARINE · NORTH KINGSTOWN, RI, UNITED STATES · built 2012
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3435 - Convention (Subpart B), Gross Ton
7278 - Dead Weight, Gross Ton
2897 - Regulatory (Subpart C or D), Gross Ton
2035 - Convention (Subpart B), Net Ton
2897 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
18 August 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8467451
21 July 2025
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8190725
29 May 2025
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8147030
30 October 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8026614
14 July 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742276
6 February 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7633527
20 September 2022
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7562197
9 August 2022
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528672
23 August 2021
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7294058
3 March 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7149796
30 July 2020
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7202555
15 August 2019
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6783953
11 September 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6537630
18 July 2018
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6483140
10 October 2017
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6284390
23 August 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249207
9 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6043234
22 August 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5979507
26 January 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848275
28 July 2015
Internal Structural Exam · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5198435
4 August 2014
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4943832
31 July 2013
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4670205
2 October 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4455548
24 September 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4448964
20 August 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4416841
7 August 2012
MTSA Verification · Initial Certification · MARPOL Annex VI Survey · Construction Oversight · MARPOL Annex I Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4403693
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 August 2021
Resolved
The frame of support of each required semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck.
The semi-portable extinguisher was not permanently attached to the deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 31 August 2021
Resolution: Def corrected. No further action required.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 August 2019
Resolved
No stowage position or muster and embarkation station for a survival craft on a tank vessel may be located on or above a cargo tank, slop tank, or other tank containing explosive or hazardous liquids.
Liferaft is stowed on a cradle directly above #05 cargo tank.
46CFR199.290(c)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2019
Resolved 19 September 2019
Resolution: Liferaft stowage position moved from cargo tank top to above after void space.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 4 August 2014
Resolved
Each ungrounded system must be provided with a ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground. Ground detection bulb is out, vessel must repair bulb ensuring there are no grounds on board. (46CFR111.05-25)
Condition: Improper/Lack of Maintenance
Due 19 August 2014
Resolved 6 August 2014
Resolution: Vessel repaired bulbs and ensured there were no grounds on board.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 4 August 2014
Resolved
Each tank must have an alarm in the vent of loss of power to the alarm system of failure of electrical circuitry to the tank level sensor. Loss of power alarm is inoperable, repairs must be made ensuring blue visual alarm acknowledges loss of power to tank level sensors. (46CFR39.20-7(b)(2))
Due 19 August 2014
Resolved 6 August 2014
Resolution: Repairs made by Electrician to the loss of power alarm. Inspectors tested alarm, confirmed blue visual alarm.
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 August 2012
Resolved
Obtain IOPP/Obtain approval for accidental outflow calculations IAW MARPOL Annex I, Reg 23 prior to engaging on international voyage.
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 24 September 2012