Records from 2011 to 2026. Most recent: inspection, 30 January 2026.
Documentation record
Registered dimensions (L × B × D)67.5 ft × 26.0 ft × 8.5 ft
Registered tonnagegross 99 / net 79
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Simplified, Gross Ton
79 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
30 January 2026
Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8304285
20 January 2026
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299074
14 January 2026
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8303151
1 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8172165
30 April 2025
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8119995
11 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8091828
26 February 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8083938
26 September 2023
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7798562
9 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7648329
26 January 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385951
29 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7373416
24 November 2020
Damage Survey · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7101161
24 November 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7123562
20 May 2020
Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6956376
2 June 2017
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6164132
23 February 2015
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5074889
19 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4755208
19 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4770464
25 July 2011
Industry Initiated Exam · MARPOL
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4096020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 January 2026
Resolved
A CLEAN AGENT EXTINGUISHING SYSTEM MUST BE ABLE TO BE AUTOMATICALLY OPERATED BY A PNEUMATIC HEAT ACTUATOR AS WELL AS A REMOTE MANUAL CONTROL. INSTALLED SYSTEM DOES NOT AUTOMATICALLY ACTUATE. RETURN SYSTEM TO ORIGINAL SPECIFICATIONS.
46 CFR 136.110,
46 CFR 95.16-20(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 4 March 2026
Resolution: Automatic activation system was reinstalled IAW manufacturer's specifications. Vessel provided pictures of report and installed system. Pictures and report uploaded in the documents tab.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 February 2025
Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals: A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel's drydock and internal structural exam was due 31DEC2024.
//46 CFR 137.300(a)//
Action required: 705 - Other - as specified
Resolved 30 April 2025
Resolution: COI inspection conducted, satisfactory
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 February 2025
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel's annual exam is overdue.
//46 CFR 137.200//
Action required: 705 - Other - as specified
Resolved 30 April 2025
Resolution: COI inspection complete, DD/ISE dates edited.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 January 2022
Resolved
"A towing vessel that is certificated for coastwise, whose construction was executed on or after August 27,2003, must be equipped with both: An approved 160-B semi-portable fire-extinguishing system to protect the engine room, and a fixed fire-extinguishing system installed to protect the engine room."
Due to low availability of the clean agent bottles for the fixed system, the vessel is unable to complete installation of the fixed system. Vessel is able to operate with the 160-B semi portable extinguisher, until the clean agent bottles are installed for the fixed system by March 31st.
46 CFR 142.315(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2022
Resolved 30 March 2022
Resolution: Clean Agent bottles were installed on board
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 November 2020
Resolved
Starboard side gunnel and tow bits were damaged (bent and crushed) from the mid ship bits to the stern most bits. Crop and renew damaged gunnel and broken tow bits to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 10 December 2020
Resolution: All damage to bulwarks and gunwale have been satisfactorily repaired with new steel. See uploaded photos for details.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 24 November 2020
Resolved
The Stbd side bulkhead, forming the super structure just above the engine room and above the bulkhead deck, was punctured compromising the watertight integrity of the structure. Crop and renew to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 10 December 2020
Resolution: All damage to superstructure and bulkheads have been satisfactorily repaired with new steel. See uploaded photos for details.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 November 2020
Resolved
The vsl owner,operator or master of a towing vsl must ensure that the vsl's lifesaving, fire suppression and detection system is in good working order. The fire detection system panel status showed battery and trouble fault indicators. Have authorized technician trouble shoot, correct errors and provide technician's report attesting to the proper operation of the fire detection system alarm panel to the USCG New Orleans inspection office.
Action required: 705 - Other - as specified
Due 1 December 2020
Resolved 30 November 2020
Resolution: Received, reviewed and accepted third party tech report attesting to faulty connection as cause of the fire detection panel fault. Connection repaired and system tested satisfactorily. See uploaded tech report for details.