MAURY USCG vessel records
← All vessels

MSC JOANNA

MSC JOANNA is a 2006 freight ship. The Coast Guard has recorded 32 inspections since 2016, most recently in May 2024, along with 18 deficiencies and 11 operational controls.

Records from 2016 to 2024. Most recent: inspection, 1 May 2024.

Built
2006
Last inspected
1 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2024
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9304435
1148261
Flag
PANAMA
Maury page id
psix-1148261

Documentation record

Tonnage as PSIX records it157367 - Displacement, Metric Ton
121138 - Dead Weight, Metric Ton
108930 - Convention (Subpart B), Gross Ton
61479 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

1 May 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7901985
25 July 2023 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7751500
19 January 2023 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7622985
5 January 2023 PSC A · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7616417
27 October 2022 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7584714
23 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7564871
7 June 2022 PSC A · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7470701
4 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6806945
2 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6801845
18 June 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6718408
13 June 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6712621
4 April 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6655569
3 April 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6655475
29 March 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6651908
26 January 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6615435
10 January 2019 COE-Administrative · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6608449
12 January 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6336788
6 November 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6296080
1 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298958
27 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6296198
27 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6296290
23 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249930
18 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6244709
13 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6175186
9 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6170433
6 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6119500
2 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6115893
17 January 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072660
13 January 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6070462
3 November 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6034397
1 November 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6033658
28 October 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6031209

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 July 2023 Resolved
STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST A-0 CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. PER REGULATION AND APPROVED FIRE CONTROL PLAN, STAIRWAY DOOR LEADING TO BRIDGE SHALL BE SELF-CLOSING AND WAS NOT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 July 2023
Resolved 25 July 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 January 2023 Resolved
The safety management system should ensure compliance with mandatory rules and regulations; and that applicable codes, guidelines and standards recommended by the Organization, Administrations, classification societies and maritime industry organizations are taken into account. The combination of deficiencies below indicates a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit shall be carried out by the Administration or the RO before the ship may be released from detention. SOLAS 74 (94 Amend.) IX/3.1 ISM Code 1.2.3
Action required: 30 - Ship detained
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 January 2023 Resolved
Life-saving appliances shall be in working order and ready for immediate use. PSCO observed STBD lifeboat/rescue boat failed to engage propulsion during operational test. Upon further examination, the lifeboat’s gearbox bolts attaching it to drive shaft were sheared. (ISM Related) SOLAS 74 (2020 Amend.) III/ 20.2 SOLAS 74 (2020 Amend.) IX/3.1 ISM Code PART A 10.3
Action required: 30 - Ship detained
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 5 January 2023 Resolved
The fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed the fire detection panel in the bridge was in fault status and could not be cleared. (ISM Related) SOLAS 74 (2009 cons.) II-2/14.2.1.1.2 SOLAS 74 (2009 cons.) IX/3.1 ISM code Part A 10.3
Action required: 30 - Ship detained
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 January 2023 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self-closing doors at all levels. Per regulation and approved fire control plan, stairway door leading to bridge shall be self-closing and was not. 74 SOLAS (2009 cons.) CH II-2/9.2.3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 5 January 2023 Resolved
The company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. Missing/inaccurate/outdated records for: annual lifeboat/ rescue boat servicing, certification of life raft servicing personnel, lifeboat weekly test, GMDSS radio weekly test, portable fire extinguisher checks, medicine storage inventory (narcotics mixed with over the counter), SOLAS training manual,SOPEP inventory and maintenance of line throwing appliances. 74 SOLAS (2020 cons.) IX/3.1 ISM Code 11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 5 January 2023 Resolved
Every ship of 100 gross tonnage and above shall carry a garbage management plan which the crew shall follow. Crews garbage was not segregated in accordance with the plan; plastics were found in food waste. MARPOL 73/78 (2022 cons.) V/10.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 January 2023
Resolution: Class DNV provided survey reports clearing deficiency, attached in Documents
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 September 2022 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO identified fuel leaking from the number 3 and 8 fuel injectors. Leaks from these fuel injectors produced a high volume of exposed flammable liquid collecting on each cylinder head and aerated vapors significantly elevating flammability. Additionally, oily substances were identified leaking from the encoder on the engine and the alpha lubricator for the cylinder oil. 74 SOLAS (04)II-2/4.1.1 30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 September 2022
Resolution: Attached Class survey attests to satisfactory repair of all items mentioned.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 September 2022 Resolved
Precautions shall be taken to prevent oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces. PSCO identified saturated lagging around the fuel pipe assembly on the main engine. This lagging was so saturated that fuel was leaking from it. The same condition was found in large portions of the lagging in the purifier room. 74 SOLAS (04) II-2/4.2.2.6.2 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 September 2022
Resolution: Attached Class survey attests to satisfactory repair of all items mentioned.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 September 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Multiple flammable liquid leaks, incomplete repairs and expansive areas of oil-saturated lagging onboard demonstrate that current procedures for engineering maintenance are not being implemented adequately enough to keep the vessel’s equipment in properly functioning service. An ISM audit is required. 74 SOLAS (20) IX/3.1 ISM CODE 10.1 30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 September 2022
Resolution: ISM Audit was conducted and recommendations were provided. Audit report is attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 September 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce a minimum any danger to persons on board. Due regard being paired to moving parts, hot surfaces and other hazards. Several motors in the purifier space were missing protective guards. Thus leaving high speed rotating machinery exposed. SOLAS (04) II-1/26.1 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2022
Resolution: Attached Class survey attests to satisfactory repair of all items mentioned.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 September 2022 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. A steam pipe for the #2 main circulation pump was found to be steadily leaking water demonstrating its inadequacy in withstanding required working stresses. 74 SOLAS (04) II-1/33.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2022
Resolution: Attached Class survey attests to satisfactory repair of all items mentioned.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 23 September 2022 Resolved
The condition of the ship and it’s equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. An emergency light fixture in the purifier room was identified to be broken and loosely supported by metal wire. A section of overhead piping in the purifier room was found to be patched with tape and oil saturated rags. SOLAS (04) I/11 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2022
Resolution: Attached Class survey attests to satisfactory repair of all items mentioned.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 June 2022 Resolved
15109- The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The vessel's SMS states that the second engineer is responsible for the maintenance of the lifeboat engines and reporting any discrepancy to the Chief engineer. As stated in deficiency #2 third engineer was not able to provide any records supporting that the weekly checks were conducted. Furthermore, the SMS states Chief Engineer shall promptly inform the Master of any machinery damage. Neither the Chief Engineer or the Master were aware of the condition of the lifeboat engine as described in deficiency #3. Deficiencies #2-#5 provide evidence of a serious lack of effectiveness of the planned maintenance system and required routine inspections/rounds by the ship's crew. Due to objective evidence in the above deficiencies the vessel is not in substantial compliance with the relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An internal audit is required within 3 months to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the audit report to the USCG when completed. 74 SOLAS (20) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 9 June 2022
Resolution: An internal audit is required within 3 months to determine whether the shp is operating in accordance with the ISM.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 7 June 2022 Resolved
15110-In meeting these requirements, the company should ensure that inspections are held at appropriate intervals. Vessel Crew was not able to provide evidence to support that engineer's weekly checks were conducted on the lifeboats. 74 SOLAS (20) IX/3.1 ISM Code 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2022
Resolved 9 June 2022
Resolution: checklist was formed by Chief Engineer considering the lifeboat engine manufacturer manual weekly checklist and agreed to be added to the SMS system officially.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 June 2022 Resolved
11103-Each survival craft shall be stowed in a state of continuous readiness. PSCO observed broken Jacket water cap on the Port Side lifeboat and the starboard side lifeboat Jacket water reservoir empty. 74SOLAS(20) III/13.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2022
Resolved 9 June 2022
Resolution: Port side jacket water cap and coupling mechanism were found repaired by welding and found in order. Both side lifeboat jacket cooling reservoirs were checked and found full levels.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 June 2022 Resolved
041114-Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of power. Vessel Captain disclosed emergency generator batteries were not functional. Vessel Company was notified on 01 June 22 but the vessel have not received timeframe for resolution from the company. 74SOLAS(20) III/ 13.1.4 LSA Code 3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2022
Resolved 8 June 2022
Resolution: New batteries were supplied on board and connected by ship electrician. Emergency gen operationally tested and found in order
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 June 2022 Resolved
11103-The hand held flares shall be contained in a water resistant casing. PSCO observed excessive corrosion on lifeboat hand flares which were not stored on a water resistant casing. 74 SOLAS(20) III/13.1.4 LSA Code 3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2022
Resolved 9 June 2022
Resolution: existing handheld flares for both side lifeboats were placed inside the watertight bags in the lifeboats accordingly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.