MAURY USCG vessel records
← All vessels

STAR RUNNER

STAR RUNNER is a 2011 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in July 2025, along with 7 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 7 July 2025.

Built
2011
Last inspected
7 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 July 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9441415
1153092
Flag
LIBERIA
Maury page id
psix-1153092

Documentation record

Tonnage as PSIX records it57809 - Displacement, Metric Ton
68970 - Dead Weight, Metric Ton
33064 - Convention (Subpart B), Gross Ton
20094 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TORM DAPHNE Tank Ship · MISLE 1333857 · 14 April 2017 · activity 6134089

Inspection history · 13

7 July 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8178301
11 June 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8152947
27 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7921108
21 April 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7672836
9 October 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6831795
5 October 2019 COE-Administrative · Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6828821
8 November 2018 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6577165
26 June 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6456760
25 June 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6454953
15 April 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6124856
14 April 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6134089
26 January 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5803873
23 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5802229

Deficiency record · 7

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 June 2025 Resolved
ALL SHIPS OF 500 GROSS TONNAGE AND UPWARD SHALL...HAVE: RUDDER, PROPELLER, THRUST, PITCH, AND OPERATIONAL MODE INDICATORS, OR OTHER MEANS TO DETERMINE AND DISPLAY RUDDER ANGLE,..., ALL TO BE READABLE FROM THE CONNING POSITION. PSCO OBSERVED STARBOARD BRIDGE WING RUDDER ANGLE INDICATOR INDICATING AN ERROR OF TEN DEGREES DIFFERENCE FROM ACTUAL RUDDER POSITION. 74SOLAS(AMEND)V/19.2.5.4 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 15 June 2025
Resolution: Received and accepted class report attesting to repairs and satisfactory test conducted on affected equipment.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 June 2025 Resolved
EACH FIRE DRILL SHALL INCLUDE: CHECKING OF FIREMANS OUTFIT AND OTHER PERSONAL RESCUE EQUIPMENT. PSCO OBSERVED SCBA AIR CYLINDERS NOT OPENED ADEQUATELY AND LEAKING REGULATOR DURING FIRE DRILL. 74SOLAS(AMEN)III/19.3.5.2.3 60ac
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 15 June 2025
Resolution: Received and accepted report from company superintendent attesting to satisfactory drills and training conducted.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 June 2025 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED THE EMERGENCY FIRE PUMP TOOK 15 MINUTES TO BE BROUGHT ON LINE BY THE CREW AND PRODUCE FIREFIGHTING WATER AT THE DECK HOSES. CREW WAS ABLE TO IMMEDIATELY BRING THE SYETEM TO SERVICE UPON SUBSEQUENT ATTEMPT AFTER VERIFYING VALVE ALIGNMENT. 10c 74SOLASII-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2025
Resolved 11 June 2025
Resolution: Crew verified valve alignment and were able to bring system online and into immediate working condition. Attending PSCO observed system functioning before concluding examination.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 June 2025 Resolved
ALLEYWAYS, STAIRWAYS, AND EXITS GIVING ACCESS TO THE MUSTER AND EMBARKATION STATIONS SHALL BE LIGHTED. PSCO OBSERVED 06 EMERGENCY LIGHTS ON DECK NOT ILLUMINATED DUE TO EXTINGUISHED BULBS. 74SOLAS(AMEND)III/11.5 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2025
Resolved 15 June 2025
Resolution: Received and accepted class report attesting to repairs and satisfactory test conducted on affected equipment.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 June 2025 Resolved
STAIRWAYS AND LADDERS SHALL BE SO ARRANGED AS TO PROVE READY MEANS OF ESCAPE TO THE LIFEBOAT AND LIFERAFT EMBARKATION DECK FROM PASSENGER FROM PASSENGER AND CREW ACCOMMODATION SPACES IN WHICH THE CREW IS NORMALLY EMPLOYED, OTHER THAN MACHINERY SPACES. PSCO OBSERVED A WATER BARREL BLOCKING THE LADDER LEADING TO THE EMBARKATION DECK. CREW REMOVED BARREL. 74SOLAS(AMEND)V/19.2.5.4 10c
Action required: 10 - Deficiency Rectified
Due 11 June 2025
Resolved 11 June 2025
Resolution: Crew removed barrel from escape route to the satisfaction of attending PSCO.
14 - Pollution Prevention › 148 - Ballast Water › Extraordinary Condition Claims
Issued 10 June 2024 Resolved
"THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF A VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST EMPLOY ONE OF THE FOLLOWING BALLAST WATER MANAGEMENT METHODS: (1) INSTALL AND OPERATE A BALLAST WATER MANAGEMENT SYSTEM (BWMS) THAT HAS BEEN APPROVED BY THE COAST GUARD UNDER 46 CFR PART 162. ...FOLLOWING INSTALLATION, THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF THE VESSEL SUBJECT TO THIS SUBPART MUST PROPERLY MAINTAIN THE BWMS IN ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS." THE VESSEL'S BALLAST WATER MANAGEMENT SYSTEM WAS REPORTED AS INOPERABLE DUE TO SYSTEM FAILURE. 33CFR151.2025(a)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2025
Resolution: Rcvd Tech report from August 5th, 2024 stating repair was made and system is operational
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 26 January 2016 Resolved
As stated in the dispensation letter from the flag state, the vessel has an inoperable echo sounding device.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 January 2016
Resolution: Received tech report stating that the echo depth sounder was repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.