Records from 2015 to 2025. Most recent: inspection, 21 November 2025.
Inspection history · 18
21 November 2025
COC-CHEM Renew · Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8272426
11 December 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8046527
6 December 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8041617
4 June 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7926717
10 November 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7822645
26 July 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7515982
20 August 2021
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7283462
20 July 2020
COC-CHEM Renew · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7011543
29 June 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6460027
10 August 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6236002
25 July 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6220527
7 July 2017
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6195952
1 July 2017
Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6192485
14 April 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6134089
21 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108645
3 September 2016
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5990921
13 July 2016
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5939211
22 July 2015
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5190618
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 November 2023
Resolved
At least two inert gas blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by paragraph 2.2.1.2. Vessel's number two inert gas generator blower is inoperable. Repair to the satisfaction of the vessels class and the USCG prior to conducting cargo operations.
Cite 74 SOLAS(20)II-2/4.5.5.1.1 Action code 17AC
FSS 15.2.3.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2023
Resolved 13 November 2023
Resolution: Received class report from vessel. Team lead reviewed, briefed ACID and cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 20 August 2021
Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code.
Ships carrying toxic or flammable products or both shall be equipped with at least two instruments designed and calibrated for testing for the specific vapours in question.
Both portable instruments had low flow alarms, rendering them inoperable.
74 SOLAS (20) VII/10.1 & IBC Code 13.2.1 - 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 August 2021
Resolution: Vessel changed filter on portable instrument.
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 7 July 2017
Resolved
To discharge ballast into the waters of the United States, subject to 151.2025 of this subpart must either it meets either 151.2030(a) or 151.2025(a)(3). Vessel is a new vessel whose compliance date is on delivery. Vessel is utilizing an AMS to meet these requirements. The installed AMS is currently inoperable and has been since at least DEC2016. 33 CFR 151.2035- 40ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 July 2017
Resolution: Received technician report attesting to fact that AMS has been repaired and is fully operational at this time.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 7 July 2017
Resolved
Must maintain a ballast water management plan that will allow those responsible for the plan's implementation to comply with the requirements of this part. BWM Plan does not include instructions for compliance with current US regulations, actions for implementing mandatory BWM requirements, or procedures for coordinating BWM strategy with Coast Guard authorities. 33 CFR 151.2050(g)- 40ac
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 10 August 2017
Resolution: Received objective evidence in form of revised Appendix A5 (Management of Ballast Water and Sediments in U.S. Waters) that the BWMP meets the requirements of 33 CFR 151.2050 (g).
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 1 July 2017
Resolved
See Narative for full Deficiency write up
Action required: 15 - Rectify deficiencies by next port
Resolved 7 July 2017
Resolution: Verified vessel conducted ballast exchange 200 nm from shore on Houston ballast reports.