MAURY USCG vessel records
← All vessels

CARNIVAL RADIANCE

Built
2000
Last inspected
24 May 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2026
…with no type recorded36
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9172648
Flag
PANAMA
Maury page id
psix-11531

Documentation record

Tonnage as PSIX records it102232 - Convention (Subpart B), Gross Ton
101509 - Simplified, Gross Ton
81645 - Convention (Subpart B), Net Ton
53171 - Displacement, Ton
10033 - Dead Weight, Ton
73744 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 92 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

403 Tank Barge · MISLE 671277 · 18 January 2016 · activity 5804517

Inspection history · 92

24 May 2026 PSC A · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8378232
8 May 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8369643
1 May 2026 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8359206
5 December 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8278395
24 November 2025 COC-CVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8265410
23 May 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8142028
25 November 2024 PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8039724
31 May 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7922435
9 April 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7892709
22 December 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7864632
1 December 2023 COC-CVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7832040
30 October 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7822632
20 June 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7798970
2 June 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7753743
12 May 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7690441
14 April 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7745776
5 December 2022 COC-CVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7604241
25 October 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7584545
11 October 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7579730
10 October 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7577689
27 September 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7571358
27 September 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7572928
12 September 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7560029
19 August 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7541045
9 August 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7558254
6 June 2022 PSC B · Ballast Water Examination · ISPS Exam · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7469830
19 April 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7473170
22 March 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7416886
14 December 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7368030
13 December 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7367603
7 December 2021 COC-CVE Annual
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7361600
15 November 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352404
28 October 2021 COC-CVE Initial
Administrative · Cruise Ship National Center of Expertise · Activity 7341434
16 December 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6872451
23 August 2019 Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6792235
27 June 2019 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6727470
26 June 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6726162
25 June 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6741808
17 June 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6716882
11 June 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6710500
12 May 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683017
3 May 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6676203
22 April 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6667741
29 March 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6651971
12 February 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6632605
11 January 2019 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6608301
12 November 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579578
12 November 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579739
22 October 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6565611
21 September 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6545085
29 June 2018 MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6458169
18 June 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6447583
11 June 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6444043
18 May 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6427574
9 April 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387694
9 March 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370497
29 December 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6330191
18 December 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6325798
5 December 2017 ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6318629
27 November 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6313367
27 October 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6296270
23 October 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6293226
17 October 2017 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294181
9 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6284113
9 October 2017 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6291482
3 October 2017 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6290981
19 September 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6270290
31 July 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228020
28 July 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228122
24 July 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6232916
27 June 2017 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6188506
2 June 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6163297
17 April 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6125985
21 February 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091757
16 January 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6071491
30 December 2016 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6063399
23 December 2016 Security Breach
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6061662
14 November 2016 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6046056
10 November 2016 Administrative Inspection · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6039029
9 November 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038198
23 October 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6136484
4 September 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995377
3 July 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5982135
29 June 2016 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5923430
2 June 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5895395
1 June 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5916483
7 April 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5849136
7 April 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5849908
31 March 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5844535
8 March 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5828955
18 January 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804517
13 January 2016 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5796608

Deficiency record · 43

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 May 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the abandon ship drill PSCO observed frozen hand break cable pulleys for lifeboats #3, #4, #7, #8, #15, #16, #17, #24, and #25. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2026
Resolved 24 May 2026
Resolution: Deficiencies was rectified to the satisfaction of the CG prior to the conclusion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 May 2025 Resolved
07101 - The hull, superstructures,structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent material. Plywood was used as a temporary bulkhead to block elevator doors, adding towards fire load. Temporary bulkhead was removed. 74 SOLAS (97) II-2/23.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: Plywood installations over the elevators on 0 deck was removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 May 2025 Resolved
07120 - In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminscent strip indicators placed not more than 0.3m (300mm) above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify escape exits. Low location lighting on deck 4 amidhships aft near wedding chapel found not illuminating. 74 SOLAS (97) II-2/28.1.10
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: Low location lighting in this area is now operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2025 Resolved
07105 - Fire doors in main vertical zone bulkheads and stairway enclosures shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position on both sides of the door. Fire door 0.108 did not automatically release during fire drill. 74 SOLAS (97) II-2/30.4.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: The doors magnetic holdback release has been repaired and the door now closes automatically as intended.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2025 Resolved
07105 - The construction of all doors and door frames in A class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. Double leaf fire door 0.022, was unable to fully close to prevent the passage of smoke and flame. 74 SOLAS (97) II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: Door was satisfactorily repaired and operated in the presence of a marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2025 Resolved
07105- Electrical installations shall be usch that: the safety of passengers, crew and ship from electrical hazards will be ensured. Dead-end wires were observed back stage in the theatre room, deck 03 starboard side. Dead wires were resolved in accordance with their ship's policies. 74 SOLAS 04 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: Dead end wires were removed and capped in accordance with the ship's policies.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 May 2025 Resolved
11101 - All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. Lifeboat number 15 did not properly operate within 4 minutes, lifeboat was unable to properly function after 20 minutes of troubleshooting. 74 SOLAS (20) III/34 LSA Code 4.4.6.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 May 2025
Resolution: Lifeboat was repaired and proper operation and functionality was tested in the presence of the attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed hanging wire connected to junction box in AC Room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 26 November 2024
Resolution: Photographs porovided of wire connections repaired properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 November 2024 Resolved
Doorways and corridors and intermediate landings included in means of escape shall be not less than 900 mm in clear width. PSCO witnessed improper storage in stairwell.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 November 2024
Resolved 25 November 2024
Resolution: Corrected on spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed broken watertight seal on an exposed electrical outlet on deck 10.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 November 2024
Resolved 25 November 2024
Resolution: Corrected on spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 November 2024 Resolved
The construction of all doors and door frames in ``A'' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed missing gasket on FSD 12.009.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 November 2024
Resolved 25 November 2024
Resolution: Corrected on spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 November 2024 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. Lifeboat 14 failed to start.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 November 2024
Resolved 25 November 2024
Resolution: Corrected on spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2023 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, remote-controlled sliding or power-operated doors shall be equipped with an alarm that sounds at least 5s but no more than 10s before the door begins to move and continues sounding until the door is completely closed. PSCO observed fire screen door 10-012 with an inoperable alarm.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 1 December 2023
Resolution: The door has been repaired and now alarms while closing.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2023 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure. Through numerous operational tests, PSCO observed fire screen door 11.022 not closing at a uniform rate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2023
Resolved 6 December 2023
Resolution: Def Rectified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 December 2023 Resolved
The Load Line ring, lines and letters shall be painted white or yellow on a dark background or black in a light background. They shall also be permanently marked. PSCO observed Load Line marking on the starboard side missing contrasting colors.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 1 December 2023
Resolution: PSCO observed the load line re-painted with contrasting colors upon departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 December 2023 Resolved
Begore the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During operational test of lifeboats, PSCO observed lifeboat 6 ignition key broke in the ignition housing, rendering the lifeboat inoperable.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 1 December 2023
Resolution: Vessel repaired the lifeboats ignition and the lifeboat runs properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2023 Resolved
Double-leaf doors equipped with a latch necessary to their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. PSCO observed fire screen door 3.039 did not properly latch when closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 1 December 2023
Resolution: PSCO observed proper operation and latching of the door.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 December 2023 Resolved
The controls required in paragraph 4 and in regulation 15.2.5 shall be located outside the space concerned, where they will not be cut off in the event of fire in the space they serve. PSCO observed quick closing valve for diesel generator #2 did not operate when actuated, preventing proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 1 December 2023
Resolution: PSCO observed proper operation of the quick closing valve.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2022 Resolved
An emergency means comprised of either fixed or portable equipment or both shall be provided for two-way communications between emergency control stations, muster and embarkation stations and strategic positions on board. PSCO found internal communication for stairwell guides on deck 6 in the forward stairwell to be faulty.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 June 2022
Resolved 6 June 2022
Resolution: Telephone replaced. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 December 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. Deck 9, P/S electrical box in passageway had missing front cover and exposed wiring but was corrected before departure. Explosion proof lighting in vicinity of Big Chicken Galley was missing a cover. Handicap door amidships on port side, Deck 5, had exposed wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 9 December 2021
Resolution: Evidence of satisfactory repairs received from Lloyd's Register.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection including fire-resisting division, and protection of openings and penetrations in these divisions. Fire door 11.027 would not adequately close and would bounce off resting surface. Rectified prior to departure. Fire doors 0.052, 0.084, 1.033, 3.012, 3.051, 3.054, and 3.058 were closing too quickly (<10 sec).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 9 December 2021
Resolution: Evidence of satisfactory repairs received from Lloyd's Register.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 December 2021 Resolved
Passenger ships engaged on international voyages which are not short international voyages shall carry partially or totally enclosed lifeboats complying with the requirements of sections 4.5 or 4.6 of the Code...Port Lifeboat #22 was not immediately available for inspection. Lifeboat #22 was delivered from the pier and tested before departure. Port Lifeboat #24 engine failed during evaluation underway. Fault fuel pump is suspected to have failed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 9 December 2021
Resolution: Evidence of satisfactory repairs received from Lloyd's Register.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 7 December 2021 Resolved
Sidescuttels and windows, together with their glasses, deadlights and storm covers if fitted shall be of an approved design and substantial construction. Forward bridge window was shattered but intact. Window is also missing from Cucina del Capitano on the starboard side and has temporary wooden cover in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2021
Resolved 9 December 2021
Resolution: Evidence of satisfactory repairs received from Lloyd's Register.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 October 2021 Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm system of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accommodation and service spaces, including corridors and stariways. Newly constructed space located below the stage (deck 3, MVZ 6) is categorized as 8, this accomodation space has no fixed has no fixed fire detection nor suppression installed. No stowage of any itmes allowed in this space until proper fire detection/supression is installed. SOLAS 20 II-2/10.6.1.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 October 2021 Resolved
Fire integrity of bulkheads and decks of passenger ships, the minimum fire integirty of all bulkheads and decks shall be prscribed in tables 9.1 and 9.2. Forward bulkhead entertainment stores on deck 3, MVZ 6 are missing structural fire protection insulation around new tie-down brackets. This bulkhead is required to meet the requiremetns for an A-15 fire boundary. Additionally, all bulkheads located in the newly constructed space below the stage (deck 3, MVZ 6) are missing insulation around the tie-down brakcets; this bulkhead is required to meet standards for an A-60 fire boundary. SOLAS 20 II-2/9.2.2.3.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2021 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them down when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated, this being determined in accordance with the Fire Test Procedures Code. A-60 fire door (11.004) located in vicinity of "thermal suite", failed to fully close when released, compromising the A-60 boundary. Additionally, A-60 fire door (3.047) located on deck 3, MVZ 6 (galley) magnetic hold-back mechanism is blocked. SOLAS 20 II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2021 Resolved
The sauna door shall open outwards by pushing. Sauna door located on port side, deck 11, MVZ 6 does not open outward. SOLAS 20 II-2/9.2.2.3.4.5
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2021 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated, this being determined in accordance with the Fire Test Procedures Code. A-60 fire door (10.028) locaated in MVZ 2, deck 10 galley located in "Cucina Del Capitano" has an open key hole, and the door does not fully close, not meeting the requirements in the FTP Code for an A-60 boundary. Also, A-60 fire door located in the theater space, deck 5, between MVZ 5 & 6 did not fully close, compromising the A-60 boundary. SOLAS 20 II-2/9.4.1.1.2
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 4 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 October 2021 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of divisions, this being determined in accordance with the Fire Test Procedures Code. Four B-15 fire doors located on deck 10, MVZ 6 are not meeting requirements to meet B-15 fire safety standard; two doors are not fully closing, and the other two doors have open key holes, compromising the "B" class fire division.SOLAS 20 II-2/9.4.1.2.1
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 4 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2021 Resolved
Aids for escape shall be provided as necessary to ensure accessability, clear marking, and adequate design for emergency situations. Escape signage missing in the four following areas: MVZ 1, deck 5 stbd side fwd; MVZ 7, Deck 10 port & stbd fwd; MVZ 6, Deck 11 port side in vicinity of "thermal suite"; and between deck 5 and deck 4, frames 276-284. SOLAS 20 II-2/13.1.3
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 4 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 October 2021 Resolved
Manually operated call points complying with the Fire Safety Systems Code shall be installed throughout the accomodation spaces, service spaces, and control stations. The manual call point located on deck 4, leading to the arcade has a broken cover that needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2021
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 16 December 2019 Resolved
In meeting there requirements, the Company should ensure that...appropriate corrective action is taken. The vessel submitted urgent non conformity to replace 22 lifeboat canopies on 30MARCH2019. As of 16DEC2019 the Company has not provided the requested canopy covers for the lifeboats. 74 SOLAS (14 cons.) CH IX Reg 13.1 ISM Code Part A Reg 10.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2020
Resolved 7 December 2021
Resolution: Evidence of satisfactory repairs received during COC exam (MISLE# 7361600)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2019 Resolved
The construction of all doors and door frames in "A-Class" divisions...shall provide resistance to fire...as fas as practicable equivalent to that of the bulkheads. PSCOs observed Fire Safety Doors 3.001, 3.008, 4.015, 8.023, not closing properly. 74 SOLAS (97 Cons.) Chapter II-2, Reg. 30.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 14 January 2020
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 26 August 2019 Resolved
14699- Other - Whenever... A defect is discovered that substantially affects the efficiency or completeness of its equipment covered by this ANNEX, the Master or owner of the ship shall report at rhe earliest opportunity to the Administration, a nominated surveyor or recognized reponsible for issuing the relevant certificates. PSCOs witnessed a substantiol amount of particulate suspended in the emission gas cleaning system discharge creating areas of siscoloration in the surrounding water. MARPOL (17 CONS.) ANNEX VI/REG.5.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2019
Resolved 25 September 2019
Resolution: Classification society conducted a survey of the system and found the system to be operating as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2019 Resolved
On 25Jun2019 at approximately 1737 eastern time the vessel reported that while underway departing the Port of Key West and approximately 6 nautical miles from port and close to the sea buoy they temporarily loss power and propulsion. Prior to arrival to the next US Port, the vessel is required to submit a report from the recognized organization attesting to fully operational propulsion, steering, main source of electrical power systems
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2019
Resolved 28 June 2019
Resolution: Class conducted a survey and verified satisfactory operation of the vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 October 2018 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The #1 DG turbocharger sufferd a catastrophic failure. Additionally, the #4 DG suffered damage to the exhaust gas cylinder cam. 74 SOLAS (14) I/11(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2018
Resolved 26 October 2018
Resolution: Received class report attesting to repair.
Communications › Radio Communications › Satellite Communications Capability
Issued 9 October 2017 Resolved
Every ship shall be provided with radio installations capable of complying with the functional requirements prescribed by regulation 4 throughout its intended voyage, complying with the requirements of regulation 7, and as appropriate for the sea areas through which it will pass during its intended voyage, the requirements of either regulation 8, 9, 10, or 11. Vessel reported that the primary INMARSAT C, #2 GPS, HF radio, and MF radio were out of service. 74 SOLAS (14Cons) Chapter IV, Reg 6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2017
Resolution: Received clas report attesting to the correction of the issue.
Fire Fighting › Means of Escape › Stairways
Issued 30 June 2017 Resolved
There is a room in room construction, the crew training center on deck 0, that does not have audible alarms as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 25 August 2017
Resolution: Class report received, cleared def.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 30 June 2017 Resolved
Multiple penetrations discoverd in crew gym deck and fire screen door 0089 was modified affecting the prevention capability.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 July 2017
Resolved 5 August 2017
Resolution: Received Class atestation to proper correction of deficiency
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 June 2017 Resolved
The crew training room is not accurately reflected on the fire control plan, there is a "B" class division not shown.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 July 2017
Resolved 5 August 2017
Resolution: Received Class Attestion to proper correction of deficiency.
Lifesaving › Lifeboat › Propulsion Engine
Issued 17 April 2017 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order. Lifeboat # 4 engine is inoperable. 74SOLAS(14)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2017
Resolution: Class Report provided
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 14 November 2016 Resolved
Failure to provide advance Notice of Arrival.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 November 2016
Resolved 22 November 2016
Resolution: Issuing an NOV.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 30 June 2016 Resolved
0730- The construction of all doors in "A" class divisions, with the means of securing when closed shall provide resistance equivalent to the bulkhead in which situated. Fire screen doors 4.058, 10.007, and C015 were each found to be incapable of properly latching- 74 SOLAS (97 Consd) II-2 Reg 30.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: PSCOs verified proper operation of each identified door prior to the conclusion of the exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.