MAURY USCG vessel records Sign in
← All vessels

DECK BARGE 101

DECK BARGE 101 is a 1969 tank barge. The Coast Guard has recorded 44 inspections since 1985, most recently in April 2004, along with 23 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2004. Most recent: inspection, 21 April 2004.

Built
1969
Last inspected
21 April 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-46303

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 20 calendar years (1985–2004)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it736 - Regulatory (Subpart C or D), Gross Ton
736 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CARIBE MERCHANT Freight Ship · MISLE 257495 · 17 March 2003 · activity 1758457CARNIVAL RADIANCE Passenger (Inspected) · MISLE 11531 · 9 June 2002 · activity 1631801MISS RAMONA Towing Vessel · MISLE 107858 · 19 December 1994 · activity 173887MISS RAMONA Towing Vessel · MISLE 107858 · 20 April 1993 · activity 60678

Inspection history · 44

21 April 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2049317
14 May 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1793229
17 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1758457
9 June 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1631801
9 May 2002 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1614795
21 April 2002 Security Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1607860
16 April 2002 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1605468
17 May 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382244
29 September 2000 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449381
18 August 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433712
24 May 2000 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446930
15 June 1999 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461982
9 October 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364894
3 August 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 10537
21 May 1998 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416711
24 April 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445197
30 May 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1377731
12 September 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185460
2 June 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1192781
19 December 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 173887
2 June 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1014825
13 August 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 847001
22 April 1993 Damage Survey · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 829593
20 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 60678
6 April 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 837524
8 June 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 957800
24 July 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308278
16 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930663
13 July 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902301
13 July 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932766
13 July 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1269125
18 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925982
12 March 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1218112
1 February 1990 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1235460
5 April 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 895754
29 March 1989 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1197334
17 February 1989 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1351770
17 May 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1194841
5 March 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1313843
1 May 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001549
26 February 1986 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 985268
18 December 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301449
15 March 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1291870
13 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 975997

Deficiency record · 23

Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002 Resolved
REPAIR AND PROVE PROPER OPERATION OF HIGH LEVEL ALARM SYSTEM. UNTIL ITEM CLEARED BY ATTENDING COAST GUARD MARINE INSPECTOR THE BARGE LOADING IS RESTRICTED TO 80% OF CAPACITY AND 2 QUALIFIED TANKERMAN ARE TO BE ON BOARD FOR ENTIRE LOADING EVOLUTION. LEGACY COMPONENT DESC: Emergency Control Systems (tank barges)
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 13 May 2002
Personnel
Issued 21 April 2002 Resolved
Watchman was found asleep twice within two hours. Verified Coastal policy that the watchman shall be awake at all times.
Action required: 705 - Other - as specified
Resolved 9 May 2002
Construction/Loadline
Issued 17 May 2001 No resolution recorded
At next drydock or internal exam, demonstrate that 3 doubler plates on maindeck aft starboard side are reinforcement plates, not doublers. If determined to be doublers then they should be removed.
Condition: Unknown
Due 30 October 2003 — due date passed with no resolution recorded
Construction/Loadline
Issued 17 May 2001 Resolved
SUBMIT REPAIR PROPOSAL FOR ITEM #NA01 TO [name withheld] 25MAY01.
Condition: Unknown
Due 25 May 2001
Resolved 21 May 2001
Deck/Cargo
Issued 17 May 2001 Resolved
PROVE OPERATION OF DECK LIGHTS.
Condition: Unknown
Due 25 May 2001
Resolved 17 May 2001
Deck/Cargo
Issued 17 May 2001 Resolved
PROVE OPERATION OF HIGH LEVEL/OVERFILL ALARMS.
Condition: Unknown
Due 25 May 2001
Resolved 17 May 2001
Navigation
Issued 24 May 2000 Resolved
Make permanent repair to fwd starboard navigational light stanchion. Prior to night time operations.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Navigation
Issued 24 May 2000 Resolved
Paint Navigation light screens matt black. Prior to night time operations.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Repair holed portside butterworth coaming in way of number 2 cargo tank, prior to loading cargo into number 2 tank.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Deck/Cargo
Issued 24 May 2000 Resolved
Make repairs to port and starboard cargo containment, used for loading cargo. Prior to loading cargo.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Deck/Cargo
Issued 30 May 1996 Resolved
CARGO HOSES TO BE PRESSURE TESTED AT 225 PSI PRIOR TO TRANSFERING CARGO WITH HOSES OR BY COMPLIANCE DATE.
Condition: Unknown
Due 30 May 1996
Resolved 30 May 1996
Deck/Cargo
Issued 30 May 1996 Resolved
CARGO PUMP ENGINE EMERGENCY SHUTDOWN FAILED TO WORK PROPERLY.
Condition: Unknown
Due 15 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 24 July 1991 Resolved
PAINT IN DRAFT MARKS ON VESSEL'S BOW TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1991
Resolved 24 July 1991
Construction/Loadline
Issued 1 February 1990 Resolved
NAME ON STERN FADED.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 1 February 1990 Resolved
MISSING DOG FWD HATCH.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 1 February 1990 Resolved
FWD EXPANSION TRUNK PORT HATCH HAS SMALL HOLE AND WASTAGE AT ITS BASE.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Deck/Cargo
Issued 1 February 1990 Resolved
CARGO PIPING EXTERNALLY PITTED. REQUIRED GAUGING NEXT DDX.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 29 March 1989 Resolved
UPON OFFLOADING CARGO TANK #4, CARGO TANK #4 IS TO REMAIN EMPTY OF ANY CARGO UNTIL ACCEPTABLE REPAIRS HAVE BEEN EFFECTED TO THE DAMAGED AREA.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 17 February 1989 Resolved
POST OIL DISCHARGE PLACARD.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Construction/Loadline
Issued 17 February 1989 Resolved
FINISH WELDING ON TWO DECK HATCHES AND STERN RAKE FRAMES.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Deck/Cargo
Issued 17 February 1989 Resolved
FINISH INSTALLING NEW FLAME SCREENS.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Fire Fighting
Issued 17 February 1989 Resolved
PROVIDE TWO FULLY-CHARGED, B-II FIRE EXTINGUISHERS, IN APPROVED BRACKETS, ON BOARD.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Documentation
Issued 17 February 1989 Resolved
PROVIDE OIL TRANSFER PROCEDURES AND PERSON-IN-CHARGE DESIGNATION ON BOARD.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989

Ownership record