Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Net Ton 80 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 26 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 October 2021Resolved
Vessel shall provide means for closing each ventilator and other openings into the machinery space in case of fire. The port and starboard Engine Room Vents were inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Ventilation closure was operational to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 October 2021Resolved
Bilges , storage areas, and void spaces shall be free from accumulating combustible/ flammable materials or liquids. Oily rags and excessive oil was observed in the bilge and must be disposed IAW 33CFR155.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Vessel's bilge was cleaned to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021Resolved
Electrical systems and equipment must function properly and minimize system failures. The starboard generator was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: The stbd generator was operational and MI witnessed the generator able to take ship's load.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 October 2021Resolved
Emergency lighting and power shall function as designed and be tested every 3 months. Neither the emergency lighting or the emergency power operate when the vessel turned off the power from the operating generator.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Emergency lighing was installed and tested to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 October 2021Resolved
Vessel shall have at least a Rigid Buoyant Apparatus while operating on a Lake, Bays, and Sounds route; properly stowed; and properly equipped. Vessel did not have any survival craft installed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vsl had installed 6 man life float with light & painter with weak link for float free deployment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021Resolved
Lifejackets shall be properly marked with the vessels name and equipped with lifejacket light and whistle. Vessel's lifejackets did not have vessel's name stenciled and the lifejackets lights did not work.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Check all six (6) lifejackets on board. All marked properly and had whistle with current chem. light.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 October 2021Resolved
Vessels operating within 3 miles from shore on a Lakes, Bays, and Sounds route shall have 3 day and 3 night Visual Distress Signals. The 3 day and 3 night Visual Distress Signals onboard expired in 2014.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vessel had six (6) new red hand day/night flares on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 October 2021Resolved
The electrical system shall function properly and minimize system failures, fire hazards & shock hazards. The frequency gauge on the port generator showed 65Hz indicating that either the gauge was faulty or the port generator was being overspeed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: The gauge was replaced to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021Resolved
The electrical system shall function properly and minimize system failures, fire hazards & shock hazards. The port generator battery charger was hanging from the outlet and stretched to the battery.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Port Generator battery charger was mounted to horizontal beam, off the deck, with a power cord of sufficient length from outlet to battery.
Watertight or weathertight integrity shall be maintained for cabins or hull penetrations which open to the exterior of the vessel. One of the galley weathertight door did not seal properly and light was seen from the outside.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Replaced lower damaged section of door and re-gasketed. Conducted chalk test with seal to satisfaction of MI. (Photos attached in Def. documents)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 October 2021Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel had charts dated 2011 and were not updated; Vessel did not have current or updated publications of Coast Pilot, light list, river stages or tide tables.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vessel had current Coast Pilot, light list, tide tables and navigation chart of operating area. Instructed vessel rep and crew on maintaining charts up to date based on LNMs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 October 2021Resolved
Fire Detection System shall be installed, tested, and maintained IAW manufacturer's manual and arranged so fire in ER automatically notifies operating station. Vessels' Fire Detection System was disabled by crew by removing leads to battery and panel until MIs questioned the operation of the Fire Detection System. Master connected the battery and leads; system was operational when MIs left the vessel. Update: Vessel's fire detection failed and was replaced during the week of 14 FEB 2022. MI waiting on tech report and PE letter.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Conducted test of fire alarm panel with Heat detector in E/R and smoke in berthing, both sat and with audible/visual alarm. Crew demonstrated knowledge of fire alarm panel functions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2021
Resolved 12 October 2021
Resolution: Vessel completed Initial COI Inspection.
Recorded names · 1
CANAVERAL (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.