Records from 1993 to 2024. Most recent: inspection, 15 February 2024.
Inspection history · 26
15 February 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7885217
2 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7631059
12 October 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7331370
13 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7196000
8 December 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4203905
31 May 2009
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3492131
20 November 2008
Administration
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3366671
5 October 2006
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2794363
11 February 2005
Hawser Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2290810
11 February 2005
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2349410
10 February 2005
MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2290783
4 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1950278
20 November 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 154232
9 June 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 61574
17 May 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 112083
7 February 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 110162
10 July 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 95026
19 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 173887
19 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 221528
3 December 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 498
23 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 150115
23 September 1993
Type not recorded
No type recorded · Commandant (CG-INV) · Activity 220669
27 August 1993
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 664377
16 August 1993
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 87976
20 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 60678
20 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 214878
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 October 2021
Resolved
Vessel shall provide means for closing each ventilator and other openings into the machinery space in case of fire. The port and starboard Engine Room Vents were inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Ventilation closure was operational to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 October 2021
Resolved
Bilges , storage areas, and void spaces shall be free from accumulating combustible/ flammable materials or liquids. Oily rags and excessive oil was observed in the bilge and must be disposed IAW 33CFR155.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Vessel's bilge was cleaned to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures. The starboard generator was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: The stbd generator was operational and MI witnessed the generator able to take ship's load.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 October 2021
Resolved
Emergency lighting and power shall function as designed and be tested every 3 months. Neither the emergency lighting or the emergency power operate when the vessel turned off the power from the operating generator.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: Emergency lighing was installed and tested to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 October 2021
Resolved
Vessel shall have at least a Rigid Buoyant Apparatus while operating on a Lake, Bays, and Sounds route; properly stowed; and properly equipped. Vessel did not have any survival craft installed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vsl had installed 6 man life float with light & painter with weak link for float free deployment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
Lifejackets shall be properly marked with the vessels name and equipped with lifejacket light and whistle. Vessel's lifejackets did not have vessel's name stenciled and the lifejackets lights did not work.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Check all six (6) lifejackets on board. All marked properly and had whistle with current chem. light.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 October 2021
Resolved
Vessels operating within 3 miles from shore on a Lakes, Bays, and Sounds route shall have 3 day and 3 night Visual Distress Signals. The 3 day and 3 night Visual Distress Signals onboard expired in 2014.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vessel had six (6) new red hand day/night flares on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 October 2021
Resolved
The electrical system shall function properly and minimize system failures, fire hazards & shock hazards. The frequency gauge on the port generator showed 65Hz indicating that either the gauge was faulty or the port generator was being overspeed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 February 2022
Resolution: The gauge was replaced to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
The electrical system shall function properly and minimize system failures, fire hazards & shock hazards. The port generator battery charger was hanging from the outlet and stretched to the battery.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Port Generator battery charger was mounted to horizontal beam, off the deck, with a power cord of sufficient length from outlet to battery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 October 2021
Resolved
Watertight or weathertight integrity shall be maintained for cabins or hull penetrations which open to the exterior of the vessel. One of the galley weathertight door did not seal properly and light was seen from the outside.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Replaced lower damaged section of door and re-gasketed. Conducted chalk test with seal to satisfaction of MI. (Photos attached in Def. documents)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 October 2021
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel had charts dated 2011 and were not updated; Vessel did not have current or updated publications of Coast Pilot, light list, river stages or tide tables.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
Resolution: Vessel had current Coast Pilot, light list, tide tables and navigation chart of operating area. Instructed vessel rep and crew on maintaining charts up to date based on LNMs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 October 2021
Resolved
Fire Detection System shall be installed, tested, and maintained IAW manufacturer's manual and arranged so fire in ER automatically notifies operating station. Vessels' Fire Detection System was disabled by crew by removing leads to battery and panel until MIs questioned the operation of the Fire Detection System. Master connected the battery and leads; system was operational when MIs left the vessel. Update: Vessel's fire detection failed and was replaced during the week of 14 FEB 2022. MI waiting on tech report and PE letter.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2022
Resolution: Conducted test of fire alarm panel with Heat detector in E/R and smoke in berthing, both sat and with audible/visual alarm. Crew demonstrated knowledge of fire alarm panel functions.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 May 2021
Resolved
Vessel is required a COI IAW 46CFR136.202
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2021
Resolved 12 October 2021
Resolution: Vessel completed Initial COI Inspection.