Records from 2002 to 2025. Most recent: inspection, 9 June 2025.
Documentation record
Registered dimensions (L × B × D)250.0 ft × 50.0 ft × 12.0 ft
Registered tonnagegross 1,260 / net 1,260
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 March 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1260 - Simplified, Gross Ton
1260 - Simplified, Net Ton
4070 - Displacement, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 45
9 June 2025
Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8150413
9 October 2024
Examination of Repairs · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8016699
28 November 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7607803
16 July 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7510086
12 May 2022
COI Inspection · MTSA Verification · Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7444426
10 April 2020
Administrative Inspection · Annual Inspection · MTSA Verification · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6937906
28 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6938606
28 June 2018
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6514870
12 June 2017
MTSA Verification · COI Inspection · Hull Examination · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6168600
25 August 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5997081
22 December 2015
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5823165
9 March 2015
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5081064
18 August 2014
MTSA Verification · Administrative Inspection · In-Service Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4958610
27 June 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4901503
24 October 2013
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4740479
21 September 2012
Hull Examination · Administrative Inspection · COI Inspection · Cargo Tank Internal · Internal Structural Exam · Load Line/Change of Employment
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4446596
30 August 2012
Load Line/Change of Employment
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4424439
6 December 2011
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4202457
29 August 2011
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4129920
21 September 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3855762
5 April 2010
Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3712018
14 September 2009
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3594081
22 June 2009
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3511048
31 May 2009
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3492131
22 September 2008
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3330272
8 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3179953
17 January 2008
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3132576
14 September 2007
Internal Structural Exam · Hull Examination · COI Inspection · Load Line/Change of Employment
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3061207
11 September 2007
Load Line/Change of Employment
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3055194
15 August 2007
Load Line/Change of Employment
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3029046
9 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2817877
8 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2816785
23 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2806022
17 January 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2568183
15 January 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2567245
19 April 2005
Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2331471
11 February 2005
MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2344546
10 February 2005
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2290745
7 November 2004
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2236305
15 October 2004
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2221471
4 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1956849
30 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1917267
21 January 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1734967
9 November 2002
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1707674
24 October 2002
COI Inspection · Initial Certification · Internal Structural Exam · Construction Oversight · Hull Examination · Deadweight Survey · Cargo Tank Internal
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1692269
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 6 December 2011
Resolved
Stowage of diesel fuel (used for cleaning/wiping up HFO) observed in un-suitable type containers. Provide suitable containers for diesel fuel.
Action required: 705 - Other - as specified
Due 6 December 2011
Resolved 3 January 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2011
Resolved
Unsuitable type of wiring found installed for sensor to tachometer on port side prime mover. Renew wiring with wiring type recommended by prime mover/tachometer manufacturer.
Action required: 705 - Other - as specified
Due 6 December 2011
Resolved 3 January 2012
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 21 September 2010
Resolved
Starboard cargo transfer pump prime mover noted with inoperable RPM gauge. Renew and ensure proper operation.
Due 21 September 2010
Resolved 21 September 2010
Resolution: Corrected prior to completion of inspection.
Operations/Management › Cargo Transfer/Lightering › Making a Connection
Issued 21 September 2010
Resolved
Two-block preventing counter-weight installed on the crane not operational. Ensure properly functions to prevent damage.
Due 21 September 2010
Resolved 21 September 2010
Resolution: Corrected prior to completion of inspection.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 23 October 2006
Resolved
Vessel is to renew wasted injector lines for the starboard side cargo pump prime mover NLT 23NOV06.
Action required: 705 - Other - as specified
Due 23 November 2006
Resolved 9 November 2006
Resolution: Cleared this date.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 23 October 2006
Resolved
Vessel is to renew wasted diesel fuel return line for the starboard side cargo pump prime mover NLT23NOV06.
Action required: 705 - Other - as specified
Due 23 November 2006
Resolved 9 November 2006
Resolution: Cleared this date.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 23 October 2006
Resolved
Vessel is renew wasted pressure lines to the engine turbo on the starboard side cargo pump primer mover NLT 23NOV06.
Action required: 705 - Other - as specified
Due 23 November 2006
Resolved 9 November 2006
Resolution: Cleared this date
Pollution Prevention/Response › Prevention Equipment › Emergency Control Systems (tank barges)
Issued 23 October 2006
Resolved
Vessel is to renew wasted sections of oil spill containment boom IAW it's approved VRP requirements or remove from vessel NLT 23NOV06.
Action required: 705 - Other - as specified
Due 23 November 2006
Resolved 24 October 2006
Resolution: Unserviceable boom has been removed from the vessel since there is no regulatory requirement for an inland tank barge to carry it.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 October 2006
Resolved
Vessel is to provide evidence of user fee payment NLT 23NOV06.
Action required: 705 - Other - as specified
Due 23 November 2006
Resolved 24 October 2006
Resolution: User fee has been paid.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 17 January 2006
Resolved
Demonstrate proper operation of the #1 port cargo tank P/V valve to the satisfaction of the attending marine inspector prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2006
Resolved 18 January 2006
Resolution: P/V valve housing was loose - once resecured P/V''s operated properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 January 2006
Resolved
Cargo piping pressure gauges are to be calibrated prior to conducting cargo operations and to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2006
Resolved 18 January 2006
Resolution: Gauges were calibrated.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 17 January 2006
Resolved
Provide valid cargo handling gear inspection report prior to using crane to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2006
Resolved 18 January 2006
Resolution: Valid crane inspection certificate was provided.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 15 October 2004
Resolved
The port shut down was repaired and several satisfactory test were conducted. Issued CG-835 to replace shutdown.
Due 19 October 2004
Resolved 18 October 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 September 2003
Resolved
REPAIR EMERGENCY SHUT-DOWN OF PORT PRIME MOVER.
Condition: Improper/Lack of Maintenance
Due 30 September 2003
Resolved 30 September 2003
Documentation › Safety/Response Plans/Programs
Issued 24 October 2002
Resolved
Provide CG approval letter for Vessel Response Plan. LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2002
Resolution: Verified approval letter during COI inspection of 304. Approval letter cited in narrative.