Records from 2016 to 2025. Most recent: inspection, 1 July 2025.
Inspection history · 16
1 July 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8170561
3 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7947899
13 June 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7933844
8 June 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851416
5 April 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7420737
10 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7409561
1 September 2021
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7301853
17 July 2020
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7008999
17 July 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7009048
20 February 2020
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6890672
2 July 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6743760
19 February 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6617373
21 February 2018
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6372484
9 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6358567
13 February 2017
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6087141
10 February 2016
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811240
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Fuel filter-water separating bowl contained excess water to the degree that inspectors believed continued operation without draining could reasonably lead to propulsion engine failure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 11 August 2025
Resolution: Vessel operator provided picture evidence of the clean fuel filter without any sediment inside.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage.
Valve on Fuel filter-water separating bowl was not fitted with a cap.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: MI's obersved fuel filter-water separating bowl fitted with a hose and the bottom with a cap to prevent leakage.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 July 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Inspector observed emergency fuel shutoff valves without marked direction of operation without indication of each pull-handles' corresponding tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: MI's observed direction of operation posted for emergency fuel shutoff valves.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 1 July 2025
Resolved
...the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings and bulwarks and their attachment to the hull structure.
A crack was observed on the port side sail railing, reducing its overall integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: The crack on the port side sail railing was repaired by welding.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel.
The vessel's original COD was not onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: The original COD was oberved onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2025
Resolved
A power-driven vessel underway shall exhibit: sidelights.
The port side navigation light did not illuminate when powered on.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: The port side navigation light bulb was replaced and illuminates when energized.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2025
Resolved
Each lifeline on a ring life buoy must be of at least 18.3 meters (60 feet) in length.
The lifeline attached to the life ring buoy was 50 feet in length.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: The lifeline attached to the life ring buoy was replaced with a 75' lifeline.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Expired contents were observed in the first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 7 August 2025
Resolution: Vessel operator replaced expired contents in the first-aid kit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2024
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Replace bracket on forward portable fire extinguisher.
46 CFR 181.500 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 17 July 2024
Resolution: Bracket installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 July 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Repair navigation light wiring since lights are currently non-operational.
46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 16 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Install lifejacket donning placard.
46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 17 July 2024
Resolution: Donning placard installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 July 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Post emergency broadcast placard at the helm.
46 cfr 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2024
Resolved 17 July 2024
Resolution: Placard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 July 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Replace guard for shaft and other rotating machinery.
46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 3 July 2024
Resolution: Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 April 2022
Resolved
An exposed hazard must be properly protected by a cover guard or rail. Power take off is uncovered and exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 6 May 2022
Resolution: Picture received of winch covered.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 September 2021
Resolved
Vessel is currently in dry storage at Sunset Watersport’s facility in Stock Island, FL awaiting sale or acquisition of insurance. Vessel placed into laid up status. Must complete a COI Renewal prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2022
Resolution: COI inspection completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 July 2020
Resolved
Make vessel available for a visual examination of the propeller shafting prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2020
Resolved 20 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 February 2020
Resolved
Reattach transom drain plug penetration, housing was pulled off of transom during drydock.
Action required: 705 - Other - as specified
Resolved 3 March 2020
Resolution: repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 February 2020
Resolved
Repair/replace engine room deck hatch securing device, 1 of 2 devices was found missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 3 March 2020
Resolution: latch replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020
Resolved
Replace bolt on clutch linkage for hydraulic winch pump, 1 of 4 bolts was found missing from assembly. Properly torque to manufactures specifications.
Action required: 705 - Other - as specified
Resolved 3 March 2020
Resolution: bolt replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 February 2020
Resolved
Grind down identified areas on STBD FRP hull and make available for re-inspection. Estimated 10 blisters found 1 foot above keel spanning aft to stern.
Action required: 705 - Other - as specified
Resolved 3 March 2020
Resolution: Repairs conducted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2019
Resolved
Provide updated Drug Testing Program
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2019
Resolved
Repair uncapped wires in anchor locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2019
Resolved
Replace retro tape on six adult and one child lifejacket
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 February 2019
Resolved
Ensure vent covers provide a vapor tight seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 February 2018
Resolved
Provide current/updated charts and required nav pubs
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 1 March 2018
Resolution: Provided current nav pubs and chart for area vessel operates.
Construction/Loadline › Structures › Scuttle
Issued 21 February 2018
Resolved
Repair dogs on forward watertight hatch.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 1 March 2018
Resolution: Replaced broken dogs on hatch.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 February 2017
Resolved
High water alarms not labeled at operating station.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 5 April 2017
Resolution: Labeled alarms
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 13 February 2017
Resolved
No log has been maintained for required drills or emergency equipment maintenance.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Discussed requirement with vessel rep, rep would begin required log.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2017
Resolved
Provide first aid kit with all required contents IAW 160.041.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 5 April 2017
Resolution: Purchased approved first aid kit
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 February 2016
Resolved
Wire penetration in Engine Space was not properly sealed to make watertight.
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 24 February 2016
Resolution: Penetration sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 February 2016
Resolved
Removed several dead end wires not in use anymore.
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 24 February 2016
Resolution: Wires removed.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 February 2016
Resolved
Emergency instructions did not reflect actual procedures/equipment
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 25 February 2016
Engineering › Bilge Water Management System › Not Operational
Issued 10 February 2016
Resolved
Automatic bilge pumps did not have functioning visual indicators
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 25 February 2016