MAURY USCG vessel records
← All vessels

DEMA

Built
2011
Last inspected
15 April 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2025
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9416446
1155467
Flag
BARBADOS
Maury page id
psix-1155467

Documentation record

Tonnage as PSIX records it34059 - Dead Weight, Metric Ton
43721 - Displacement, Metric Ton
23985 - Convention (Subpart B), Gross Ton
10652 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIRBY MORAN Towing Vessel · MISLE 1332449 · 30 August 2024 · activity 8004969JRT MORAN Towing Vessel · MISLE 1368255 · 30 August 2024 · activity 8004969

Inspection history · 19

15 April 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8111922
1 September 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7993608
30 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7992772
30 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8004969
29 August 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991736
28 August 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991151
26 August 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7989874
25 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8003467
20 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7985633
24 April 2023 Administrative Inspection · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7672271
16 December 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7111466
15 December 2020 COE-Administrative · Administrative Inspection · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7110431
15 February 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6909794
3 September 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6802212
2 September 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6801840
5 June 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6704354
13 May 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6683035
27 March 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644331
20 December 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6060465

Deficiency record · 9

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 August 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The operational and technical nature of the generator failure, main engine astern failure, and loss of steering failure provide objective evidence of a serious failure of the implementation of the ISM code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency 74SOLAS(20)IX/3.1 ISM Code Part A/10.1
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2024 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Vessel reported vessel unable to clutch astern during propulsion checks at pier. 74SOLAS(20) II-1/28.1
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 August 2024
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 26 August 2024 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey... is necessary. If the ship is in a port of another Contracting Government, the master or owner shall also report immediately to the appropriate authorities of the port State and the nominated surveyor or recognized organization shall ascertain that such a report has been made. Vessel reported to PSCDO that while underway to the pilot station inbound, the vessel lost power. Cite: 74 SOLAS (2) I/11(c) Code: 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2024
Resolution: Recieved RO Report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2023 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed steam leaks on valve flange and pipe flange to boiler pressure relief valve. 74 SOLAS (amend.) II-1/26.1, Prior to Departure, Code 17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2023
Resolved 30 April 2023
Resolution: Received class report documentation from DNV stating all outstanding deficiencies have been rectified. The class report stated: Steam pipe and boiler valve gaskets were replaced and both found in proper order.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 April 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems. PSCO observed a main power supply fault on the fire control panel due to a damaged DC converter. 74 SOLAS (amend.) II-2/14.2.1.1.2, Prior to Departure, Code 17 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2023
Resolved 30 April 2023
Resolution: Received class report documentation from DNV stating all outstanding deficiencies have been rectified. Fire alarm system main supply of power was verified to supplied from main source of power after installation of spare converter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely impacted its fitness and capability to safely maneuver the Houston Ship Channel. Submit for review a Classification Society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2019
Resolution: Class Report Statig repairs were satisfactory and Vessel proved to have normal Maneuverablity.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2019 Resolved
07106 Fire Safety The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems. PSCO observed faults on bridge fire alarm panel. Captain provided documentation stating that four smoke detector heads had failed and replacements had been requested from company. 74SOLAS(2014 Cons Ed)II-2/14.2.1.1.2 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 30 March 2019
Resolution: Received, reviewed and accepted class report for DNV-GL stating the deficiency was rectified. Fire protection services reprogramed and completed a function test satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 March 2019 Resolved
11129 Life Saving Appliances Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed seven emergency lights were not operational. 74SOLAS(2014 Cons Ed)III/20.2 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 30 March 2019
Resolution: Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. Crew replaced broken lights, all emergency lights are working properly.
Operations/Management › Pollution › Ballast Water Management
Issued 20 December 2016 Resolved
40a: THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF ANY VESSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN U.S. WATERS MUST REMOVE FOULING ORGANISMS FROM THE VESSEL'S HULL ON A REGULAR BASIS. EXCESSIVE BIOFOULING WAS OBSERVED ON THE HULL.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2019
Resolution: Received documentation attesting removal of marine growth from the hull.

Ownership record