Records from 2013 to 2026. Most recent: inspection, 1 April 2026.
Inspection history · 22
1 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8338873
19 February 2026
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8312322
6 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8090145
8 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7862312
6 February 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7861762
11 January 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7620089
14 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7395865
6 December 2021
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7362949
15 September 2021
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7322860
4 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7135876
8 January 2021
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7121778
8 January 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7123302
6 February 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6905031
4 February 2020
Internal Structural Exam · Drydock Exam · Periodic Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6906877
5 November 2019
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6850055
4 November 2019
Type not recorded
No type recorded · Station Charleston · USCG Southeast District (CGD-SE) · Activity 6849209
28 January 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6615825
16 February 2018
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6355794
18 January 2018
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6356384
31 January 2017
DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6080092
19 January 2016
Examination of Repairs · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5809508
5 January 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5791305
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2026
Resolved
Visual and audible alarm must be provided at the operating station to indicate a high water level. Port middle high water console alarm not operational.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Vessel made repairs and suppied video.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2026
Resolved
Visual and audible alarm must be provided at the operating station to indicate a high water level. STBD aft high water console alarm not operational.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Vessel made repairs and suppied video.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 1 April 2026
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions. Bullhorn was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Vessel has new bullhorn.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 1 April 2026
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Top deck of vessel was missing the placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Vessel attached instruction placards
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2026
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have three (21/2 gallon) buckets, w/ an attached lanyard. Missing 1 fire bucket
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Vessel acquired 05 fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 April 2026
Resolved
Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q, Three hand orange smoke distress signals approved in accordance with § 160.037. Flares are expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: vessel purchased new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026
Resolved
A vessel must carry one floating waterlight.
Vessels waterlight was unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: vessel has a new waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Ring life buoy was not labeled with boat name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: vessel labeled the ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 April 2026
Resolved
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least (8 inches) in length and (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint.
Vessel did not have load marks on sideshell.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: Loading marks were applied to the hull.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2026
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Starboard fwd extinguisher was not mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 15 April 2026
Resolution: vessel has the extinguisher mounted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 April 2026
Resolved
An internal structural examination conducted in compliance with § 176.600 complete examination of the vessel's main strength members, including the major internal framing.08 Tab Joints on crossbeams, delaminated inside of starboard hull marked yellow X'S
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2026
Resolved 24 April 2026
Resolution: Tab joints repaired and photos provided showing work through out stages with final repairs being completed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 1 April 2026
Resolved
A vessel must comply with the applicable requirements for any radio, installations, to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Radio did not indicate GPS position on screen. Vessel is restricted to 1000 feet from shore until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 April 2026
Resolution: Vessel is changing the routes and conditions and remove the requirement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 March 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in any space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.
Bilge alarm float switch in port aft section is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 20 March 2025
Resolution: Vessel representative provided videos of new high water level alarm float switch installation and alarm operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2025
Resolved
The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds.
Grab line on life ring needs to replaced
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 20 March 2025
Resolution: Vessel representatives replaced ring life buoy including grab line with new type approved ring life buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 March 2025
Resolved
A hatch exposed to the weather must be watertight.
Gaskets on the hatches located on the forward main deck are deteriorated and allowing water to enter into the compartments they cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 20 March 2025
Resolution: Gaskets on each hatch were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 March 2025
Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date copy of the U.S. Coast Pilot and Coast Guard Light List.
Current Coast Pilot and Light List are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 20 March 2025
Resolution: Updated Coast Pilot and Light List were printed out and placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
09 life jackets aboard are unserviceable.
Action required: 705 - Other - as specified
Resolved 20 March 2025
Resolution: 09 new type approved lifejackets have been placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 10 January 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Air compressor pressure switch was not covered.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 7 February 2022
Resolution: Received photograph showing a new cover was placed in service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2022
Resolved
Except as noted in § 176.114 of this part, each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel limits were not posted at the helm as required by COI.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 7 February 2022
Resolution: The vessel's limitations were placed at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessels life jacket donning type were not aligned with donning instructions.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 7 February 2022
Resolution: The proper donning instructions were placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 February 2021
Resolved
Vessels operated solely within 20nm of land must be equipped with a VHF - DSC radiotelephone installation meeting the requirements of 80.1101(c)(2).
Vessel does not have GPS coordinates tied into the VHF.
Vessel restricted to 1000ft from shore.
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 10 March 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 8 February 2021
Resolved
On a vessel of not more than 65 feet in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions. The bullhorns batteries are to be continually maintained at a fully charged level by use of a battery charger or other means acceptable to the cognizant OCMI. Vessel does not have a bullhorn or public address system on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2021
Resolved
Each connection to a conductor or a terminal part of a conductor must be made within an enclosure and have either a pressure type connector on each conductor, a solder lug on each conductor, or a splice made with a pressure type connector to a flexible lead or conductor.
Vessel has a bilge wire in port hull connected to cable not in an enclosure with electrical tape. In generator room there is wires coming together with a twist on type wire nut not in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2021
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel identified areas on deck and deck beams that need repair. Wood is rotted in various locations. Vessel submitted repair proposal and to rapair December 2021.
Action required: 705 - Other - as specified
Resolved 10 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constent marine load under such requirements without exceeding its designed limitations.
Vessel experiened engine failure on of the two outboard engines. Examination of repairs and functional tests must be conducted before the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 February 2020
Resolved
Each ring life buoy on a vessel must meet the standards of 46 CFR 160.050 and at least one ring life buoy must be fitted with a lifeline. Ring buoy is missing retro-reflective tape, and current lifeline does not meet the minimum requirement of 5/16" diameter. Retro-reflective tape to be added and lifeline to be replaced.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 14 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 February 2020
Resolved
Placards containing instructions for donning life jackets must be posted in conspicuous places. Vessel has no posted life jacket placards. Life jacket donning placards to be posted on both decks.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 14 February 2020
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 12 February 2020
Resolved
All emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR." Emergency exit only has "exit" labeled on one side of door. Labels to be added above emergency exit on both sides.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 14 February 2020
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 12 February 2020
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the vessel. Vessel is missing emergency broadcast placard at operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 14 February 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 12 February 2020
Resolved
Emergency Instructions shall be mounted at the operating station. Emergency instructions/procedures are located approximately 10ft aft of the operating station not permanently mounted. Emergency operating procedures to be moved to the operating station and permanently affixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 14 February 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 February 2020
Resolved
To maintain a valid Certificate of Inspection, the owner/operator must make a vessel available for drydock examinations in the intervals required by this section. Vessel was due for drydock exam on 31Jan2020. Vessel is restricted from carrying passengers until this is conducted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2020