Records from 1996 to 2021. Most recent: inspection, 28 June 2021.
Documentation record
Registered dimensions (L × B × D)57.5 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTOCHE ENTERPRISES INC · OCEAN SPRINGS, MS, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICKASAW, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
28 June 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7238019
24 March 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161922
3 March 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7149780
7 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4852380
20 November 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4495133
11 September 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4439053
7 May 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4304216
26 April 2012
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4296684
26 April 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4298975
7 October 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4163467
28 November 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2830159
25 May 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2658554
22 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2666676
13 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2566492
31 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2035068
31 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2035083
21 December 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1986611
13 February 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522363
23 February 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112181
23 February 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 206733
23 February 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759752
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 3 March 2021
No resolution recorded
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: all bilges and void spaces are kept free of accumulation of combustible and flammable materials and liquids insofar as practicable. MI noted a significant amount of oily water and fuel in bilge and in containment for both generators.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2021
No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency circumstances. MI noted several dead-end wires throughout engine room and machinery spaces, vessels main batteries in trays without covers and filled with water, broken electrical junction boxes exposing AC electrical wires.
Action required: 30 - Ship detained
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021
No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency circumstances. MI noted significant leak in STBD and PORT shaft housings beyond acceptable limits.
Action required: 30 - Ship detained
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 March 2021
No resolution recorded
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. No documented maintenance for combustion engines could be provided. MI identified substantial oil leak on STBD and PORT crank cases and STBD exhaust manifold.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2021
No resolution recorded
All fire suppression equipment and systems on-board a towing vessel must be maintained in accordance with manufacturers approved design and NFPA 10 as applicable. MI noted severely wasted portable fire extinguishers and brackets, 160-B semi portable extinguisher not secured to vessel structure, and no proactive documentation log for recording required inspections by a member of the crew.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 March 2021
No resolution recorded
Piping and machinery components that exceed 428 degrees must be insulated. MI noted no lagging was present on the STBD engine exhaust piping.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2021
No resolution recorded
Vessel must undergo a Subchapter M compliance survey in coordination between company TSMS TPO and internal survey provider and provide objective evidence of compliance with the SMS and Subchapter M requirements prior to operations. Vessel may not be towed or moved under it own power without approval from the OCMI.
Action required: 30 - Ship detained
Operations/Management › Pollution › Control of Garbage
Issued 25 May 2006
Resolved
vsl did not have a marpol garbage placard posted
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2006
Resolution: placard was installed on bulkhead in vsl
Fire Fighting › Fire Pumps › Location
Issued 23 May 2006
Resolved
Vsl did not have a fire pump.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2006
Resolution: Installed fire pump.