Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMOBILE, AL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 44 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 11 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 44
25 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8314933
20 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087898
13 March 2024
Internal Structural Exam · Administrative Inspection · COI Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7878992
23 March 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7655813
7 June 2022
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7479568
14 February 2022
Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7396311
24 March 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161922
11 March 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7154162
23 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144952
11 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6924437
22 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6359715
19 August 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6245246
8 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6100906
12 June 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5947561
21 February 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5819238
26 January 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5803592
5 February 2015
MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5064995
22 December 2014
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5042987
5 November 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5026002
30 July 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4943639
14 February 2014
MTSA Verification · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4794885
7 December 2012
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4500350
30 October 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4475212
19 January 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4251223
15 October 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4174412
6 August 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3822012
20 April 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3720207
14 July 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3534264
18 May 2009
Examination of Repairs · Welding Related Inspections Qualification Testing
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3478142
16 January 2009
MTSA Verification · Drydock Exam · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3395292
16 June 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3238627
15 August 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3028673
23 May 2007
COI Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2937245
2 June 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2668139
6 September 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2485338
19 August 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2467832
8 June 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2383448
20 October 2004
MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2225010
1 June 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2084629
20 January 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1988759
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968419
20 May 2003
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1797539
31 December 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1726328
24 May 2002
Internal Structural Exam · Hull Examination · Initial Certification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1620542
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 March 2026
Resolved
Each nonrising-stem valve, lever-operated valve, or other valve where, because of design, the position of the disc or closure mechanism is not obvious must be fitted with an indicator to show whether the valve is opened or closed. The middle valve for the #2 tank was missing the valve position indicator.
46CFR56.20-9
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2026
Resolved 7 April 2026
Resolution: Received evidence that valve indicator was replaced. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 April 2024
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The following weld repairs are required:
- 1P void, bay 2, aft outboard vertical is cracked at intersection of #3&4 side longs (counting from bottom to top)
- 2P void, bay 3, after outboard vertical is cracked at intersection for #3 side long
- 3P void, bay 4, aft outboard vertical is cracked at intersection of #4&5 side longs
- 4P void, bay 2, fwd outboard vertical is cracked in vicinity of #3 long. Crop and renew section of vertical btwn 2&3 and 3&4 side long
- bow void, cracked weld on 2nd transverse frame, most outboard port longitudinal
- bow void, cracked weld on 2nd transverse frame, most outboard stbd longitudinal
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 16 April 2024
Resolution: attended vessel for fianl repairs, all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 March 2024
Resolved
Every tank vessel subject to the regulations in this subchapter shall be inspected every 5 years or more often, if necessary, by the Coast Guard. EBS-1's Certificate of Inspection expired 28FEB2024. The vessel is not permitted to operate until the barge has completed their Internal Structure Exam and Renewal Inspection and is issued a new COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2024
Resolution: conducted COI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 March 2024
Resolved
Tank vessels which are laid up, dismantled, and out of commission are exempt from inspections required by law or regulations in this subchapter, provided that such vessels are cleaned of all cargo residue and maintained in a gas free condition. The barge is prohibited from being moved without the permission of the OCMI and must be gas freed no later than 26MAR24.
Action required: 705 - Other - as specified
Resolved 9 April 2024
Resolution: conducted COI and ISE
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 March 2023
Resolved
46CFR39.2007
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm. Must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled. Audible alarm not functioning properly. Repair/Replace.
Restricted from loading cargo until resolved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 4 April 2023
Resolution: Replaced speaker. Alarm is fully operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 March 2023
Resolved
46CFR35.01-50(e)
Barges shall not be moved from a loading facility unless all bilges and void spaces are substantially free of water. Remove water from FWD void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 4 April 2023
Resolution: Pumped out water. Voids are clear.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2023
Resolved
46CFR35.05-15(3)(iii)
All cargo tank hatches must be clearly marked in not less than three inch lettering "Danger-Keep Out". Warning is not legible. Re-stencil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 4 April 2023
Resolution: Re-Stenciled "Danger Keep Out"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 March 2023
Resolved
46CFR32.35-1
46CFR62.50-20
Vessel must have a planned maintenance program to ensure continued operation of all vital systems. Generator has oil leak and not being properly maintained. Repair as
necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 4 April 2023
Resolution: Oil leak secured
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 February 2022
Resolved
The remote quick acting manual shutdown shall for an internal combustion engine driven cargo pump shall be installed so as to provide a quick and effective means of stopping the engine. Remote shutdown wire is frayed due to chaffing. Repair or replace wire and provide means for engine remote shutdown to be tested.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2022
Resolution: Wire replaced and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 February 2022
Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers. Port side L/O pump cover was broken and corroded. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 17 February 2022
Resolution: Received photo evidence of replaced cover. Uploaded to docs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 February 2022
Resolved
A pressure gauge shall be installed for each pump discharge. Pressure gauge on both port and stbd L/O tank pump are broken. Replace gauges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 17 February 2022
Resolution: Photos of replaced gauges received. Uploaded to docs.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 February 2021
Resolved
Draft marks must be painted in contrasting color to the hull. Observed all draft marks missing paint. Paint draft marks in contrasting color to the hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 11 March 2021
Resolution: Photos submitted of painted draft marks.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 June 2006
Resolved
Vessel had a non UL approved electrical outlet located in hazardous location. Required vessel representative to replace with approved type or remove.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 26 June 2006
Resolution: Vessel removed non UL approved electrical outlets to the satisfaction of the attending marine inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 2 June 2006
Resolved
Vessel's prime mover fuel supply hoses were in need of repair. Hoses were worn due to lack of maintenance and could not tell if the hoses met the J1942 standards. Advised vessel representative to replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 26 June 2006
Resolution: Vessel representative replaced hoses for prime mover to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 2 June 2006
Resolved
Port side hand grab bar was broken and in need of repair. Advised vessel representative to renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2006
Resolved 26 June 2006
Resolution: Vessel representative renewed grab bar to the satisfaction of the attending marine inspector.