Inspection history · 51
7 January 2014
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4778945
24 May 2012
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4320578
21 May 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3743565
22 July 2009
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3542579
14 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3554809
7 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2954563
8 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2924591
10 May 2006
Internal Structural Exam · Cargo Tank Internal · Hull Examination · MTSA Verification · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2645718
20 January 2006
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2569827
10 January 2006
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2565651
3 June 2005
MTSA Verification · Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2374239
19 April 2005
MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2338057
6 April 2004
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2038445
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968409
3 April 2003
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1760381
22 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1735052
31 December 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1726328
12 April 2002
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1604410
20 March 2002
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1495553
24 May 2001
COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1382249
22 March 2001
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1395655
6 April 2000
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1050097
31 March 2000
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1397383
25 June 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1420157
22 January 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 204
28 May 1998
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1444016
13 February 1998
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1431914
11 February 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 81159
20 August 1997
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 783404
22 July 1997
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1375063
24 June 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 643834
24 June 1996
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 933965
24 June 1996
Hull Examination · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1189916
24 April 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 190659
24 April 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 763654
24 April 1996
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1080661
20 April 1995
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1170143
7 April 1994
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 856772
28 April 1993
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1132773
1 May 1992
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 960897
2 May 1991
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1217804
14 February 1990
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 918039
15 February 1989
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1038682
9 March 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1337765
18 February 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1020698
25 January 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1014708
3 April 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1021877
28 February 1986
COI Inspection · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1297062
7 February 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305567
11 June 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 473372
12 February 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 977352
Construction/Loadline › Hull › Side Shell
Issued 7 January 2014
Resolved
Make perminant repairs to stbd stern corner (fractured) prior to loading any cargo.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2014
Resolved 15 November 2022
Engineering › Fuel Oil Service System › Hose
Issued 7 May 2007
Resolved
Renew all worn fuel hoses on the s/s genset with proper SAE J1942 hoses.
Due 8 June 2007
Resolved 7 June 2007
Deck/Cargo › Holds/Tanks
Issued 20 March 2002
Resolved
Cargo tank identification marking are missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 12 April 2002
Resolution: Cargo tanks are marked with identification number.
Construction/Loadline › Markings
Issued 20 March 2002
Resolved
Hailing port marking is missing from stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 12 April 2002
Resolution: hailing port has been marked on the stern.
Documentation › Logs/Records
Issued 20 March 2002
Resolved
Provide proof of annual cargo piping/pressure gauge testing. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 12 April 2002
Resolution: Received report of annual piping/hose test conducted 03/29/2002.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 March 2002
Resolved
Place identification tags/markings on each cargo hose. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 12 April 2002
Resolution: All hoses have metal tags or identification number punched into metal coupling.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 20 March 2002
Resolved
S2 flame screen is holed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 20 March 2002
Resolution: flame screen replaced.
Lifesaving
Issued 31 March 2000
Resolved
MARK "DIESEL FUEL" ON DIESEL FUEL TANK.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 31 March 2000
Resolved
INSTALL MACHINERY GUARDS OVER METER PUMP AND SLOP TANK PUMP MOTOR BELTS ANDPULLEYS.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 31 March 2000
Resolved
SECURE ELECTRICAL CABLE LEADING INTO SLOP TANK PUMP BREAKER PANEL.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Deck/Cargo
Issued 31 March 2000
Resolved
RENEW HOLED FLAMESCREEN ON PORT LUBE OIL TANK GOOSENECK VENT.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Deck/Cargo
Issued 31 March 2000
Resolved
MARK LUBE OIL TRANSFER HOSE WITH MAWP AND "OIL SERVICE".
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Construction/Loadline
Issued 31 March 2000
Resolved
MARK VESSEL NAME AND HAILING PORT ON STERN.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Deck/Cargo
Issued 28 May 1998
Resolved
INSTALL SINGLE 30X30 MESH FLAME SCREEN MATERIAL ON #1 STBD ULLAGE OPENING AND P/V, #1 PORT P/V, #2 STBD P/V AND SLOP TANK GOOSENECK. NO CARGO OPERATIONS INVOLVING THESE TANKS MAY BE CONDUCTED UNTIL CORRECTED._x001C_
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 28 May 1998
Resolved
RENEW "DANGER-KEEP OUT" WARNING ON PORT LUBE OIL DECK TANK HATCH.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998
Resolved
PROVE PROPER OPERATION OF STBD RUNNING LIGHT. VESSEL RESTRICTED FROM OPERATION REQUIRING RUNNING LIGHTS UNTIL CORRECTED.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Deck/Cargo
Issued 13 February 1998
Resolved
MAKE PERMANENT REPAIRS TO 8 FRACTURED WELDS IN WAY OF PORT #1 CARGO TANK INTERAL SUPPORTS. REPAIRS SHALL BE COMPLETED PRIOR TO LOADING PORT #1 CARGO TANK.
Condition: Unknown
Due 20 February 1998
Resolved 17 February 1998
Construction/Loadline
Issued 13 February 1998
Resolved
MAKE PERMANENT REPAIRS TO SET IN AND FRACTURED DECK KNUCKLE IN WAY OF PORT #1 CARGO TANK. DAMAGE TO DECK KNUCKLE STARTS AT THE AFT BULKHEAD OF PORT #1 CARGO TANK. PERMANENT REPAIRS SHALL BE COMPLETED PRIOR TO ANY CARGO BEING LOADED IN PORT #1 CARGO TANK.
Condition: Unknown
Due 20 February 1998
Resolved 17 February 1998
Construction/Loadline
Issued 22 July 1997
Resolved
MARK HAILING PORT ON STERN IN LETTERS A MINIMUM OF 4" IN HEIGHT.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Deck/Cargo
Issued 22 July 1997
Resolved
REPACK P/S #1 AND 2 CARGO TANK REACH ROD STUFFING TUBES.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
INSTALL BLANK COVER IN VOID SPACE IN GENERATOR ROOM BREAKER BOX.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Deck/Cargo
Issued 24 April 1996
Resolved
VALVE HOUSING APPEARS TO HAVE PULLED LOOSE FROM SUCTION LINE. MAKE PERMANENT REPAIRS PRIOR TO LOADING ANY CARGO IN THE AFT DECK TANK AND NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Deck/Cargo
Issued 15 February 1989
Resolved
CARGO HOSES ARE NOT MARKED AS REQUIRED BY 33 CFR 154.500(F). MARK THE HOSES WITH THE WORDS "OIL SERVICE" OR THE NAME OF THE PRODUCT FOR WHICH THEHOSE IS USED AND THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989
Resolved
CARGO HOSES WERE EQUIPPED WITH QUICK CONNECT COUPLINGS WHICH WERE NOT POSITIVE LOCKING AND NOT OF A TYPE ACCEPTABLE TO THE COMANDANT. REMOVE UNACCEPTABLE QUICK CONNECT COUPLINGS AND REPLACE THEM WITH COUPLINGS WHICH MEET THE REQUIREMENTS OF 33 CFR 154.500
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 18 February 1988
Resolved
PROVIDE OVERSPEED TRIP ON GENERATOR PRIME MOVER. DEMONSTRATE PROPER FUNCTION IN THE PRESENCE OF A CG MARINE INSPECTOR NOT LATER THAN 01MAR88.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988