Records from 1994 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 65
24 November 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8273177
14 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8250437
8 January 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8060329
19 November 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8037065
13 November 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7823862
16 May 2023
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 7690814
28 March 2023
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7658611
14 March 2023
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 7651170
14 March 2023
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7651180
10 January 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7615808
30 November 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7344976
16 November 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7352333
9 June 2021
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7222275
20 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7178771
20 May 2020
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6956618
13 September 2019
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6811296
29 November 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049520
15 November 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6045342
18 October 2016
MTSA Verification · Industry Initiated Exam · Administration
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6020928
23 June 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5916433
24 September 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5735460
25 October 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5014203
15 October 2014
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5005667
16 July 2014
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4924097
16 July 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4929511
27 October 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4747151
8 May 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4586510
15 October 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4174412
13 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3914718
15 September 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3851188
22 May 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3746035
22 May 2010
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3746657
14 May 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3737979
14 May 2010
Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3738303
19 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3674340
20 August 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2830777
26 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712383
29 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2611786
10 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2608021
23 February 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2590606
6 November 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2541917
2 February 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2285160
14 January 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2275574
25 September 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2213737
17 August 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2168435
23 June 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2107936
8 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982005
5 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1975257
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990388
11 February 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1743005
15 March 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1600518
4 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 154300
4 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 19652
16 May 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 277989
20 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276135
9 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275630
4 October 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 145889
20 July 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 149724
12 April 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 45583
30 January 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 15847
30 January 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 164540
12 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 162244
15 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 378400
26 June 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 126492
6 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 6543
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 November 2025
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. Engine alarm set points must be tested, twice every 5 years, with no more than 3 years elapsing since last test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2025
Resolved 9 January 2026
Resolution: Received testing report and procedures from vsl. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 November 2025
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments and flexible cable plugs and socket outlets must be designed to prevent unintended separation. NAV and Searchlight wiring sheathing found to be chaffed and wire exposed. P/W piping leaking onto MSD control panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2025
Resolved 18 December 2025
Resolution: Satisfactory replacement of electrical wiring penetration assemblies and repaired P/W piping.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 25 November 2025
Resolved
Master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. FWD hold hatch missing dogs for securing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 15 December 2025
Resolution: Vessel provided adequate photo evidence that repairs have been satisfactorily completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2023
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM; Auxiliary generator engine cooling water temperature. STBD generator engine panel was inoperative. Add method to determine oil pressure, engine RPM, and engine cooling water temperature to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 November 2023
Resolved 1 December 2023
Resolution: Cleared from photo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 November 2023
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure and main engine RPM. Port and STBD engines did not have engine RPM gauges at the machinery location. Add RPM gauge to each engine to the satisfaction of the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 3 January 2024
Resolution: Added RPM gauge
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 November 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation. Jacket water leak was identified on STBD engine. Identify leak source, clean equipment, and make appropriate repairs to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 3 January 2024
Resolution: Received video of machinary running without leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Observed 8 inches of standing oil in bilges of the engine room. 46 CFR 143.220(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2023
Resolved 28 March 2023
Resolution: Sector New Orleans received proof of purchase receipts of new seals and a video of installation and operational testing of steering gear. No leaking visible. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Observed hydraulic oil actively streaming from port side hydraulic steering ram seal. 46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2023
Resolved 28 March 2023
Resolution: Sector New Orleans received, reviewed and accepted corresponding photos and videos of all bilge spaces clear and cleaned. Received proof of purchase receipts of new seals and a video of installation and operational testing of steering gear. All sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 January 2023
Resolved
Each towing vessel must be fitted with a general alarm that: Is capable of notifying persons in any accommodation, work space, and the engine room. Inspector discovered inoperable general alarm and light in the engine room.
46 CFR 143.235(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2023
Resolved 23 January 2023
Resolution: Replaced light.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 January 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Inspector discovered that turbocharge on starboard main was not insulated.
46 CFR 143.220(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 19 January 2023
Resolution: Lagging installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Inspector could not read the MAWP on the nameplate on the pressure vessel.
46 CFR 143.300 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 19 January 2023
Resolution: Data plate cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Multiple spare circuit breakers in the "on" position in the engine room.
46 CFR 143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 19 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Light on the upper level (starboard side) of the engine room was missing a cover, posing electrical hazard. Distribution panel located under the stack was missing a drip shield/panel.
46 CFR 143.400 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 19 January 2023
Resolution: Light cover and dip shield installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 January 2023
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment. Dryer was found to be unsecured and was able to be moved by hand.
46 CFR 140.505(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 19 January 2023
Resolution: Dryer now bolted to the deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a
propulsion engine or generator prime mover.
Front starboard fuel valve was inoperable. Repair to the
satisfaction of the attending Marine Inspector.
46 CFR 143.260(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2021
Resolved 30 November 2021
Resolution: Recieved video of F/O COV operating as designed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 November 2021
Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR or official logbook.
There were no records on board of lifesaving equipment maintenance or tests.
46 CFR 141.235(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 18 January 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 November 2021
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge or a designated member of the crew.
There were no records on board of fire fighting equipment maintenance or tests.
46 CFR 142.240(a)(1)(ii)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 7 March 2022
Resolution: Records of firefighting equipment testing and maintenance submitted
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 30 November 2021
Resolved
The master of a towing vessel must ensure that each crew member participates in firefighting drills and receives instruction at least once a month.
Drills were not being conducted every month.
46 CFR 142.245(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 18 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 November 2021
Resolved
The safety of the towing vessel is the responsibility of the master.
The master did not know how to operate the Automatic Identification System.
46 CFR 140.210(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 18 January 2022
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 November 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Can be automatic, battery-operated with a duration of no less than 2 hours or non-electric, phosphorescent adhesive lighting strips tat are installed along escape routes to facilitate egress.
No emergency lighting in berthing spaces.
46 CFR 143.410(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: Phosphorescent exit signs and emergency lighting was installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2021
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces.
Some berthing spaces had no means to detect smoke.
46 CFR 142.330(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: smoke detector was installed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 30 November 2021
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
Life float was worn and had sun damage. Replace life float.
46 CFR 141.105(b)->
46 CFR 199.190(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: lifefloat was replaced with new
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 30 November 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
The electrical breaker panel outside of the engine room labels were scratched out and rewritten by hand and there were openings in the wiring on the bottom of the breakers.
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: Panel was properly labeled and secured
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2021
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person on board during an emergency.
Titles for the positions on the Station Bill were not clear and would cause confusion during an emergency. Clearly state the differences between positions; for example, Deckhand #1 and Deckhand #2.
46 CFR 140.405(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 18 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
The washing machine and drier should be secured to the deck, as to not be a hazard while underway.
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: equipment was secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
Pressure vessels must be examined annually and relief valves tested.Stbd air compressor pressure gauge goes up to 300psi when MAWP for both compressors is 200psi. Port air compressor relief valve was inoperable and data plate painted over.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2022
Resolution: Receipt and pictures of installed relief valve and data plate submitted
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 November 2021
Resolved
Master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. Door gaskets on on main deck are insuffienct for door to be marked watertight. This door is allowed to be weathertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 December 2021
Resolution: Marked doors weathertight as designed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2021
Resolved
At least 2 lifebuoys on a towing vessel greater than 26ft fitted with a floating electric water light. Life buoy batteries only sufficiently connected on one of the buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 November 2021
Resolved
The crew of each towing vessel must demonstrate the ability to operate the primary and auxiliary machinery and electrical systems for which they are responsible. Starboard generator would not start.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2021
Resolution: Generator was ran and online prior to completing inspection
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 20 April 2021
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Vessel sustained damage as a result of collision. make proper repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2021
Resolved 10 June 2021
Resolution: Inspected repairs; all sat.
02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 20 April 2021
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Vessel sustained damage as a result of collision. Conduct damage survey to asses extent of damages and provide report of survey to the CG.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2021
Resolved 23 April 2021
Resolution: Vessel representative provided damage survey from 3rd party surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2020
Resolved
Machnery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of person onboard under normal and emergency conditions. Vessels SSDG windings had excessive oil in the windings on port and starboard. Clean windings prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 November 2020
Resolution: Received Video evidence from TBS showing both generator windings being cleaned.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 6 November 2020
Resolved
Alarms and monitoring. Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. No audible alarm on the bridge and the bilge alarm did not stay actuated on the panel in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Received video evidence provided by TBS showing that the wheel house alarm panel had an audible alarm added and was working upon activiation.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 6 November 2020
Resolved
Have a means to test actuation at each operating station or have a continuous self monitoring alarm system which actuates if an alarm point fails or becomes disabled. Vesel has no means to test the actuation of the steering alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2020
Resolution: Received video evidence from TBS showing that the crew had means to test the activiation of the the Steerin level low level alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life property, and the environment. Upon arriving the vessel did not have a proper crew on board to conduct initial inspection, Master was unaware of 46CFR140 requirements, fuel valves were in the wrong place, life float was installed incorrectly. Inspection stopped and vessel is restricted from movement until a follow up inspection is complete.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 November 2020
Resolution: Conducted an interview with the crew and verified operation of equipment on board.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 March 2000
Resolved
VESSEL DOES NOT HAVE OFFICIAL NUMBER PERMANENTLY AFFIXED ON INTERIOR HULL.
Condition: Unknown
Due 16 March 2000
Resolved 14 November 2006