Records from 2012 to 2026. Most recent: inspection, 11 March 2026.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
11 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8312208
26 February 2025
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8084952
4 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8014236
24 January 2024
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7845245
9 September 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7788158
11 January 2023
MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7620154
31 January 2022
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 7388412
21 December 2021
COI Inspection · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7369777
11 March 2021
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7155120
23 October 2019
Internal Structural Exam · Periodic Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6840303
20 March 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6645763
26 September 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6548814
19 November 2017
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6646184
29 December 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6075627
28 December 2016
MTSA Verification · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6063142
19 December 2016
Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6053624
14 July 2016
MTSA Verification · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5941735
9 July 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5939372
16 August 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5217396
14 April 2015
SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5102509
14 April 2015
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5104134
25 September 2014
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4992415
14 July 2014
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4922440
12 December 2013
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4770496
16 July 2013
SIP Initial Entry · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4639593
2 October 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4455920
23 February 2012
Internal Structural Exam · Drydock Exam · Initial Certification · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4295271
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 March 2026
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Installed storm rails on starboard side amidships are severed/broken from bulkhead. Repair rail prior to conducting cargo operations. 46 CFR 31.10-17 (a) 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2026
Resolution: Rail repaired
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 March 2026
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Installed storm rails around periphery of barge are holed and coming loose from bulkhead. Make temporary repairs to satisfaction of MI within 30 days and repair/replace permanently during next drydock.
Action required: 705 - Other - as specified
Due 11 April 2026
Resolved 8 April 2026
Resolution: New handrails installed on both sides of barge.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 11 March 2026
Resolved
The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air). Remote manual shutdown cables were found frayed. Repair/replace to satisfaction of MI. 46 CFR 32.50-35 (a) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2026
Resolved 8 April 2026
Resolution: Cables replaced and thimbles installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026
Resolved
Approved portable and semi-portable extinguishers must be installed in accordance with table 1 to § 34.50-10(a). Fire extinguisher in operator booth does not have a bracket. Install bracket to satisfaction of MI.
46 CFR 34.50-10(a), 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2026
Resolved 8 April 2026
Resolution: Bracket installed in tankerman office.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 March 2025
Resolved
CLASS 1, DIVISION 1 SPACES MAY HAVE ONLY APPROVED INTRINSICALLY SAFE, EXPLOSION PTOOF, OR PERGED PRRESSURIRIZED ELECTRICAL EQUIP AND THRU RUNS IF THE LOCATION IS WITHIN 10 FEET OF A CARGO PIPE FLANGE OR CARGO VALVE. THE GAS TIGHT GASKETS ON THE P/S PRIME MOVER PUMP SHAFTS ARE WORN AND DETERIOATED. THESE GASKETS ARE WITHIN THE VESSELS DESIGNATED CLASS 1, DIVISION 1 ZONES APPROX 5 FEET FROM CARGO PIPING DROP FLANGES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2025
Resolution: Vessel O/o replaced gast tight seal with new gasket custom cut to fit application.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Identified wiring for tanks 1P/S and 2P/S liquid level sensors have broken armor at the junction into the tank sensor. Repair or replace wiring to ensure vapor tight connection to sensor.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 November 2019
Resolution: Recieved pictures from POC showing wiring has been replaced.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 28 December 2016
Resolved
Vessel's prime mover was not capable of demonstrating proper operaton of an overspeed device. Owner must prove proper operation of overspeed device in the presence of an Coast Guard Marine Inspector. Vessel is restricted from operation until corrected. 46 CFR 111.12-1(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2016