Records from 2012 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 19
24 November 2025
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8273212
27 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7990221
23 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7853663
14 June 2021
COI Inspection · Cargo Tank Internal · MTSA Verification · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7212405
22 July 2020
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7013219
12 June 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6712128
17 July 2018
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6482405
12 December 2017
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6323336
28 July 2017
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6223263
12 July 2016
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5938071
18 March 2016
COI Inspection · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5838932
8 March 2015
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5083179
27 February 2015
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5075861
12 February 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5074070
2 April 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4827932
1 April 2014
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4821768
6 March 2014
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4815626
14 December 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4500143
23 January 2012
Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Initial Certification · Hull Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4248785
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 27 August 2024
Resolved
Low level alarm contection has slight leak inway of threaded connection. Heater needs to be shut down and drianed to conduct proper repair, Vessel presently loaded and requires Heater
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 September 2024
Resolved 27 August 2024
Resolution: Received confirmation from company TBSIP manager that MRF mechanics repaired and tested, All sat. GS
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 July 2020
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable extinguishers are maintained in accordance with NFPA 10.
Portable fire extinguishers shall be installed in a bracket incorporating releasing banks or straps or in an approved cabinet or wall recesses.
All 03 fire extinguishers mounted on deck were not adequately secured by straps or bands.
Cite: 46 CFR 31.10-18, NFPA 10 / 6.1.3.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 14 June 2021
Resolution: Cleared outstanding deficiency based on no fire extinguishers required to be on board except during transfer.
Deck/Cargo › Cargo Heating › General
Issued 26 May 2016
Resolved
Identify all leaks in thermal fluid piping, make repairs and prove repairs to attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 12 July 2016
Resolution: Witnessed satisfactorily test of thermal fluid piping
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 26 May 2016
Resolved
Conduct cargo pipe hydro, pressure gauge test and hose test (as applicable).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2016
Resolved 9 June 2016
Resolution: Received test report via email.
Documentation › Markings/Placards › Warning Signs
Issued 26 May 2016
Resolved
Repair broken "red flag" pennant.
Condition: Damaged By Earlier Event
Due 16 June 2016
Resolved 12 July 2016
Resolution: the red flag pennant was replaced with a new one