Records from 2014 to 2024. Most recent: inspection, 28 June 2024.
Inspection history · 9
28 June 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934043
20 June 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6719986
30 May 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6429058
2 April 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383799
20 February 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6358142
19 June 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6183300
9 February 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6083573
9 October 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5002410
10 March 2014
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4813091
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 February 2017
Resolved
0999 - Other (Safety in General) - The purpose of this regulation to prevent fire and explosion is to prevent the ignition of combustible materials or flammable liquids. For this purpose, there shall be means provided to control leaks of flammable liquids. Fuel oil supply valve to main engine was leaking, creating a possible ignition source due to fuel soaked lagging. 74 SOLAS (14) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Due 9 February 2017
Resolved 9 February 2017
Resolution: Corrected on the spot.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 March 2014
Resolved
1430; The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operate simultaneously. For a period of 18 hours emergency lights, steering gear, navigation lights and other safety equipment. During testing of the emergency generator, see narrative for additional info.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2014
Resolved 10 March 2014
Resolution: Crew drained the fuel tank and flushed fuel lines. Generator was tested to the satisfaction of the attending Class representative.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 10 March 2014
Resolved
2510; Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently does not have documenting items including Bio-Fouling as required by 33CFR2050(g), Reference IMO MEPC Resolution 207 (62).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2014
Resolved 10 March 2014
Resolution: Addressed and corrected to the satisfaction of the Attending Classification Representative.
Documentation › Logs/Records › Oil Record Book
Issued 10 March 2014
Resolved
1710; The Oil Record Book shall be completed on every occasion that collection of oil residue occurs. The crew is currently recording the capacity of the F.O. Save All Tank as 2.8m3, various IOPP's record the tank as 2.0m3. MARPOL Ax.I/17.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2014
Resolved 10 March 2014
Resolution: Addressed and corrected to the satisfaction of the Attending Classification Representative.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 10 March 2014
Resolved
0715; The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration. Vessel does not have appropriate means of testing the flame and heat detection system.
74SOLAS(09)II-2/7.3.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2014
Resolved 10 March 2014
Resolution: Addressed and corrected to the satisfaction of the Attending Classification Representative.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 10 March 2014
Resolved
1705; Every ship 400 Gross Tons and above shall carry onboard a Shipboard Oil Pollution Emergency Plan. The Plan shall be prepared and based on guidelines developed by the organization and shall have the list of authorities to be contacted in the event of an oil pollution incident. Vessel does not have local port contacts as per section 2.3.2 and appendix 2 of the SOPEP. MARPOL Ax.I/37.2.4
Action required: 705 - Other - as specified
Due 14 March 2014
Resolved 10 March 2014
Resolution: Addressed and corrected to the satisfaction of the Attending Classification Representative.