Records from 2016 to 2024. Most recent: inspection, 21 June 2024.
Documentation record
Tonnage as PSIX records it12134 - Regulatory (Subpart C or D), Net Ton
23264 - Convention (Subpart B), Gross Ton
12134 - Convention (Subpart B), Net Ton
38243 - Dead Weight, Metric Ton
46314 - Displacement, Metric Ton
23264 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 15
21 June 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7939328
9 June 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7710360
7 June 2023
COE-Administrative
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7706391
27 June 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7488493
21 June 2022
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7483486
30 April 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441073
30 April 2022
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441094
13 April 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7426292
1 August 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7019427
23 September 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6821424
1 July 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6722802
29 November 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6308914
21 November 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6310877
18 August 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5976424
8 August 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5960524
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2024
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE CONDITION TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITION ON BOARD.
PSCO OBSERVED REFRIGERATOR COOLING PUMP MISSING GUARDS. ADDITIONALLY PORT BUNKERING MANIFOLD MANUAL VALVE WAS LEAKING OIL.
74SOLAS(20) II-1 26.1
Action required: 10 - Deficiency Rectified
Resolved 21 June 2024
Resolution: PSCO RECEIVED IMAGES OF REPAIR BEFORE DEPARTURE FROM VESSEL
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2024
Resolution: PSCO reviewed picture evidence attesting lifeboat port and stbd bow now has port of registry and name of vessel marked IAW LSA 4.4.9.2.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2024
Resolved
UNLESS EXPRESSLY PROVIDED OTHERWISE OR UNLESS, IN THE OPINION OF THE ADMINISTRATION HAVING REGARD TO THE VOYAGE THE SHIP IS ENGAGED, ALL LIFE-SAVING APPLIANCES PRESCRIBED IN THIS PART SHALL HAVE RETRO-REFLECTIVE MATERIAL WHERE IT WILL ASSIST IN DETECTION AND IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE ORGANIZATION.
PSCO OBSERVED MULTIPLE LIFEBOUYS WITHOUT RETROREFLECTIVE MATERIAL. CREW UNABLE TO PROVIDE CERTIFICATE OF CONFORMANCE FOR LIFE-BUOYS.
74SOLAS(20) III/34
LSA 1.2.2.7
Action required: 10 - Deficiency Rectified
Resolved 21 June 2024
Resolution: PSCO OBSERVED CREW AMEND LIFEBUOYS BEFORE DEPARTURE.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 8 August 2016
Resolved
17ac- The crew could not provide the correct testing equipment according to the manufacturer's manual. Crew could not provide testing records for heat detectors and it is unknown when they were tested last. 74 SOLAS(14 cons.) II-2/7.3.2
09AUG16: The vessel was allowed to depart on condition stated in (resolution below).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2016
Resolution: 09AUG16: The Master would like to confirm that my vessel maintains a 24 hour 2 man engine room watch of an engineer and oiler. The oiler will maintain a presence in the Engine spaces and maintain a look out for any potential fire conditions.clear to dept.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 August 2016
Resolved
10c- A 55-gallon drum full of water was preventing a self closing "A" 60 boundry door from closing in the galley. It was also tied open with rope. The rope and drum of water was romoved by th crew. 74 SOLAS(14 cons) II-2/9.4.2.2
Condition: Placed in Improper Service
Due 8 August 2016
Resolved 8 August 2016
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 August 2016
Resolved
10c-Crew communal bathrooms had multiple 55-gallon drums of fresh water for crew use. One drum on the B-deck bathroom was blocking the use of a urinal. A 55-gallon drum of water was in the galley for cleaning dishes. All drums did not have a top and were exposed to the air, making them prone to bacteria growth and is an unsanitary condition. Master stated drums are for water conservation.
Due 8 August 2016
Resolved 8 August 2016
Resolution: Master ordered all drums to be removed.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 8 August 2016
Resolved
10c- Hot water supply pump was secured yesterday according to the C/E and never turned back on after maintenance was completed. Hot water was not available to the crew.
Due 8 August 2016
Resolved 8 August 2016
Resolution: Prior to leaving the ship PSCO observed hot water was available throughout the ship.