MAURY USCG vessel records
← All vessels

GARY ROOK

GARY ROOK is a 2012 industrial vessel. The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 27 deficiencies and 2 casualty investigations in 2013.

Records from 2013 to 2026. Most recent: inspection, 7 May 2026.

Built
2012
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9670353
WDG 5650
1166449
Flag
UNITED STATES
Maury page id
psix-1166449

Documentation record

Registered dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,242 / net 1,447
ITC dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,242 / net 1,447
BuilderNORTH AMERICAN SHIPBUILDING LLC · LAROSE, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3242 - Convention (Subpart B), Gross Ton
4942 - Dead Weight, Gross Ton
7549 - Displacement, Gross Ton
1447 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

7 May 2026 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8372257
31 January 2026 Appeal · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8294168
15 November 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8269490
20 November 2024 Annual Inspection · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8020577
7 September 2023 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7787055
14 October 2022 COI Inspection · Re-Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7577582
31 January 2022 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7388559
17 May 2021 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7199294
8 February 2021 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7137427
15 July 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7006853
8 January 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6888062
31 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6768651
11 February 2019 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6624026
7 November 2017 COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6302151
10 October 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6295284
5 October 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6281684
3 October 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6295285
19 April 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6127973
31 August 2016 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5988824
13 July 2016 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5959437
12 February 2016 MTSA/ISPS Verification · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5830287

Deficiency record · 27

09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 4 February 2026 Resolved
Indicators are to be provided at the control station showing whether the doors are open or closed, and an audible alarm is to be provided at the door closure. MI observed no audible alarm at the door closure of 02 sliding WTD. Master is to have the doors remain closed in-port or offhsore with only manual operation at the door allowed until an audible alarm is provided. All crew received training and Master's letter posted at the doors. Make repairs for audible alarm to be heard as required for notification of closure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 10 February 2026
Resolution: ABS assigned finding 420.0
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 4 February 2026 Resolved
Exhaust openings of tank vent systems shall be located: .4 the vent height may be reduced to 3m above the deck or fore-and-aft gangway, as applicable, provided high-velocity vent valves of an approved type, directing the vapour/air mixture upwards in an unimpeded jet with an exit velocity of at least 30m.s, are fitted, MI found the vent height at 8.5' (2.6m), make modifications to venting system prior to the carriage of methyl alcohol.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2026
Resolved 10 February 2026
Resolution: ABS assigned finding 421.0
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 4 February 2026 Resolved
Cargo tank relief-valve settings shall be a minimum of 0.02 MPa gauge. MI found the pressure relief valves set to 14Kpa (2psi). Adjust relief valve setting prior to the carriage of methyl alcohol.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2026
Resolved 10 February 2026
Resolution: ABS assigned finding 422.0
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 February 2026 Resolved
Periodic safety tests must be conducted annually to demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks and safety protocols. MI found the 2025 PSTP log sheet missing completed procedures, no log/checklist was provided for 2026. Complete corrective action plan for rectification, ensuring procedures are properly logged. ABS Supplement 11' 4-9-1/7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 10 February 2026
Resolution: ABS assigned finiding 423.0
01 - Certificates & Documentation › 011 - Ships Certificates › INF certificate of fitness
Issued 4 February 2026 Resolved
The master of the ship shall be supplied with a loading and stability information booklet. The loading manual referenced in the Certificate of Fitness is not the manual available to the Master. Correct certificate or provide adequate manual to Master.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 5 February 2026
Resolution: Vessel received new ICOF from ABS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2026 Resolved
Ships shall be provided with fire hoses, the number and diameter of which shall be to the satisfaction of the Administration. MI found 04 exterior fire stations with one 1 1/2" hose, stations are listed in the fire control plan to have two 1 1/2" hoses connected to wye gate. Appropriate spare hoses with nozzles were available onboard.
Action required: 10 - Deficiency Rectified
Due 4 February 2026
Resolved 4 February 2026
Resolution: Spare hoses available and installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 February 2026 Resolved
Fixed fire detection and fire alarm system installation shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. MI observed an inoperable heat detector over the fuel oil purifier.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 February 2026
Resolved 4 February 2026
Resolution: Spare detector was installed and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 February 2022 Resolved
Unless expressly provided otherwise, launching appliances complying with the requirements of section 6.1 of the code shall be provided for all survival craft except those which are: carried in excess of the survival craft for 200% of the total number of persons on board and which have a mass of not more that 185Kg or carried in excess of the survival craft for 200% of the total number of persons on board the ship, are stowed for launching directly from the stowed position under unfavorable conditions of trim and list. Life raft positioned on the starboard bow deck is greater than 185Kg and to large to be properly stowed and secured in the provided for manual launching arrangement. Replace with properly sized life raft or install launching arrangements per LSA code 6.1.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2022
Resolved 7 November 2022
Resolution: Newly inspected/certified 10 man Solas A pack life raft installed on existing cradle. Weight suitable. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries become inoperative. The starboard main diesel engine's battery charger was not operating and needed to be repaired or replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2022
Resolved 7 November 2022
Resolution: Starboard main diesel engine's battery charger's PCL card has been replaced. Charger functioning sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 June 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which might be established by the company. Observed numerous oil leaks on STBD Main Diesel Engine, #1 and #2 Ships Service Diesel Generators. While reviewing maintenance records it was noted that port main diesel engine was overdue for a inframe overhaul by 3662 hours, starboard main engine was past due for in-frame overhaul by 3511 hours and port generator was overdue for bearing replacement by 5426 hours. Chief engineer submitted requisition to company on 09 NOV 2020. Provide non conformity and Corrective action plan within 30 days. 74 SOLAS 2020 IX/3.1 ISM Code 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: ABS accepted deficiency as a condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional shall be met. Means shall be provided to control leaks of flammable liquids. Observed numerous oil leaks on Starboard Main Diesel Engine, #1 and #2 Ships Service Diesel Generators. 74 SOLAS 2020 II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: ABS accepted deficiency as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 June 2021 Resolved
As far as is reasonable and practical rescue boats shall be launched each month with their assigned crew aboard and maneuvered in the water. In all cases this requirement shall be complied with at least once every three months. Observed rescue boat has not been launched in accordance with the vessel schedule and this regulation. Provide non conformity and Corrective Action Plan within 30 days. 74 SOLAS 2020 III/19.3.4.6
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: ABS accepted deficiency as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 June 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Water mist system is not working as designed. 74 SOLAS 2020 II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: ABS accepted deficiency as a condition of classs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 January 2020 Resolved
Where the emergency source of electrical power is a generator it shall be capable of automatically starting and supplying the required load as quickly as is safe and practicable, subject to a maximum of 45 seconds. Vessels EDG failed to supply required load. 74SOLAS(14)II-1/43.3.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2020
Resolution: Received class report stating deficiency was rectified.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 January 2020 Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Periodic safety tests must be conducted annually to demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks and safety controls. Vessels reverse power relays failed to operate as designed on both SSDGs. 74SOLAS(14)II-1/46.2 - ABS ACP SUPPLEMENT FOR OSV'S 2017 4-9-1/7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2020
Resolution: Received class report stating deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 8 January 2020 Resolved
Before a ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Rescue boat righting lines were missing as per manufactures specifications. 74SOLAS(14)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Received class report stating deficiency was rectified.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 January 2020 Resolved
Periodic safety tests must be conducted annually to demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks and safety controls. Vessel has outdated Periodic safety test procedures. Vessel recently underwent modifications to propulsion electrical system. No approved/updated PSTPs were found onboard. Until approved PTSPs are onboard, PUMS in not authorized. An engineering live watch system shall be implemented by licensed engineers and maintained until the procedures can be approved and tested by RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Received class report stating deficiency was accepted as a condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020 Resolved
Non metallic expansion joints and piping systems shall be inspected and replaced as necessary, or at an interval recommended by the manufacturer. All non metallic expansion joints for both generators and both stern thruster were found with excessive ware/cracking. 74SOLAS(14)II-1/26.9
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Received class report stating deficiency was accepted as a condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020 Resolved
The machinery shall be so installed and protected as to reduce a minimum any danger to person onboard, due regard being paid to moving parts, hot surfaces and other hazards. Vessels main diesel engines exhaust lagging was found torn and exhaust piping exposed. Furthermore, the port engine was found with an exhaust leak. 74SOLAS(14)II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Received class report stating deficiency was accepted as a condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. All of the vessels relief valves onboard had no servicing records or maintenance history. 74SOLAS(14)IX/ISM CODE 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Received class report stating deficiency was accepted as a condition of class.
Documentation › Logs/Records › Logbook (official)
Issued 27 October 2017 Resolved
Provide properly formatted Radio log.
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Provided.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 October 2017 Resolved
Provide proof that digital SMPEP is same as stated on Approval letter.
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 27 October 2017 Resolved
Provide proper documentation of daily/weekly work/rest hours.
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Completed.
Documentation › Certificates/Documents › Permit, Other
Issued 27 October 2017 Resolved
Provide Certificate Attesting Recognition for all non-US creditialed officers IAW 46 CFR 15.720
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 14 August 2018
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 October 2017 Resolved
Provide properly formatted Garbage Record Book.
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 27 November 2017
Resolution: Completed
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 3 October 2017 Resolved
The acting Chief Engineer onboard did not have the required STCW level III/2 endorsement.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 4 October 2017
Lifesaving › Immersion Suits › Quantity
Issued 19 April 2017 Resolved
Immersion suits are required for the waters of the vessel's current operating area. Provide, stow, and maintain the immersion suits required. As an alternative, a request may be made to restrict the oceans route to operate only in areas where immersions suits are not required.
Due 30 September 2017
Resolved 18 September 2017
Resolution: Vessel has been stacked and issue will be readdressed once vessel is placed back in service.

Casualty record · 2

20 August 2013Routine · role: Involved in a Marine Casualty · activity 4694151
24 August 2013Routine · role: Source Vessel for Cargo Transfer · activity 4698219
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.